1
-
-
0035283698
-
Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformai irradiation of carcinoma of the prostate
-
3-1
-
H. Alasti, M. P. Petric, C. N. Catton, and P. R. Warde. "Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformai irradiation of carcinoma of the prostate," Int.J.Radiat.Oncol.Biol.Phys. 49[3]: 869-884 (3-1-2001).
-
(2001)
Int.J.Radiat.Oncol.Biol.Phys.
, vol.49
, Issue.3
, pp. 869-884
-
-
Alasti, H.1
Petric, M.P.2
Catton, C.N.3
Warde, P.R.4
-
2
-
-
0038372040
-
Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID
-
S. Aubin, L. Beaulieu, S. Pouliot, J. Pouliot, R. Roy, L. M. Girouard, N. Martel-Brisson, E. Vigneault, and J. Laverdiere. "Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID," Med.Phys. 30[7]: 1825-1832 (2003).
-
(2003)
Med.Phys.
, vol.30
, Issue.7
, pp. 1825-1832
-
-
Aubin, S.1
Beaulieu, L.2
Pouliot, S.3
Pouliot, J.4
Roy, R.5
Girouard, L.M.6
Martel-Brisson, N.7
Vigneault, E.8
Laverdiere, J.9
-
3
-
-
12844254281
-
Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery
-
J. H. Siewerdsen, D. J. Moseley, S. Burch, S. K. Bisland, A. Bogaards, B. C. Wilson, and D. A. Jaffray. "Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery," Medical Physics 32[1]: 241-254 (2005).
-
(2005)
Medical Physics
, vol.32
, Issue.1
, pp. 241-254
-
-
Siewerdsen, J.H.1
Moseley, D.J.2
Burch, S.3
Bisland, S.K.4
Bogaards, A.5
Wilson, B.C.6
Jaffray, D.A.7
-
4
-
-
0034866552
-
Flat-panel cone-beam CT: A novel imaging technology for image-guided procedures
-
(5-28). San Diego, CA, USA, SPIE
-
J. H. Siewerdsen, D. A. Jaffray, G. K. Edmundson, W. P. Sanders, J. W. Wong, and A. A. Martinez. "Flat-Panel Cone-Beam CT: a Novel Imaging Technology for Image-Guided Procedures," Mun, Seong K. 4319[1]: 435-444 (5-28-2001). San Diego, CA, USA, SPIE.
-
(2001)
Mun, Seong K.
, vol.4319
, Issue.1
, pp. 435-444
-
-
Siewerdsen, J.H.1
Jaffray, D.A.2
Edmundson, G.K.3
Sanders, W.P.4
Wong, J.W.5
Martinez, A.A.6
-
5
-
-
0023224718
-
Reduction of CT artifacts caused by metallic implants
-
W. A. Kalender, R. Hebel, and J. Ebersberger. "Reduction of CT artifacts caused by metallic implants," Radiology 164[2]: 576-577 (1987).
-
(1987)
Radiology
, vol.164
, Issue.2
, pp. 576-577
-
-
Kalender, W.A.1
Hebel, R.2
Ebersberger, J.3
-
6
-
-
0036030338
-
Novel method for reducing high-attenuation object artifacts in CT reconstructions
-
(5-15). San Diego, CA, USA, SPIE
-
L. M. Chen, Y. Liang, G. A. Sandison, and J. Rydberg. "Novel Method for Reducing High-Attenuation Object Artifacts in CT Reconstructions," Sonka, Milan and Fitzpatrick, J. Michael. 4684[1]: 841-850 (5-15-2002). San Diego, CA, USA, SPIE.
-
(2002)
Sonka, Milan and Fitzpatrick, J. Michael
, vol.4684
, Issue.1
, pp. 841-850
-
-
Chen, L.M.1
Liang, Y.2
Sandison, G.A.3
Rydberg, J.4
-
7
-
-
0019839830
-
An algorithm for the reduction of metal clip artifacts in CT reconstructions
-
G. H. Glover and N. J. Pelc. "An algorithm for the reduction of metal clip artifacts in CT reconstructions," Med.Phys. 8[6]: 799-807 (1981).
-
(1981)
Med.Phys.
, vol.8
, Issue.6
, pp. 799-807
-
-
Glover, G.H.1
Pelc, N.J.2
-
8
-
-
0031794571
-
Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
-
J. Hsieh. "Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise," MedPhys. 25[11]: 2139-2147 (1998).
-
(1998)
MedPhys.
, vol.25
, Issue.11
, pp. 2139-2147
-
-
Hsieh, J.1
-
9
-
-
0345708391
-
A new algorithm for metal artifact reduction in computed tomography: In vitro and in vivo evaluation after total hip replacement
-
A. H. Mahnken, R. Raupach, J. E. Wildberger, B. Jung, N. Heussen, T. G. Flohr, R. W. Gunther, and S. Schaller. "A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement," Invest Radiol. 38[12]: 769-775 (2003).
-
(2003)
Invest Radiol.
, vol.38
, Issue.12
, pp. 769-775
-
-
Mahnken, A.H.1
Raupach, R.2
Wildberger, J.E.3
Jung, B.4
Heussen, N.5
Flohr, T.G.6
Gunther, R.W.7
Schaller, S.8
-
10
-
-
5644240930
-
Segmentation-aided adaptive filtering for metal artifact reduction in radio-therapeutic CT images
-
5-12
-
C. S. Olive, M. R. Kaus, V. Pekar, K. Eck, and L. Spies. "Segmentation-aided adaptive filtering for metal artifact reduction in radio-therapeutic CT images," Proc.SPIE Int.Soc.Opt.Eng. 5370[1]: 1991-2002 (5-12-2004).
-
(2004)
Proc.SPIE Int.Soc.Opt.Eng.
, vol.5370
, Issue.1
, pp. 1991-2002
-
-
Olive, C.S.1
Kaus, M.R.2
Pekar, V.3
Eck, K.4
Spies, L.5
-
11
-
-
0033853232
-
Fast iterative algorithm for metal artifact reduction in X-ray CT
-
G. Wang, T. Frei, and M. W. Vannier. "Fast iterative algorithm for metal artifact reduction in X-ray CT," Acad.Radiol. 7[8]: 607-614 (2000).
-
(2000)
Acad.Radiol.
, vol.7
, Issue.8
, pp. 607-614
-
-
Wang, G.1
Frei, T.2
Vannier, M.W.3
-
12
-
-
2542496945
-
A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images
-
O. Watzke and W. A. Kalender. "A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images," Eur.Radiol. 14[5]: 849-856 (2004).
-
(2004)
Eur.Radiol.
, vol.14
, Issue.5
, pp. 849-856
-
-
Watzke, O.1
Kalender, W.A.2
-
13
-
-
0037153879
-
X-ray CT high-density artefact suppression in cryosurgery
-
12-21
-
J. Wei, G. A. Sandison, L. Chen, Y. Liang, and L. X. Xu. "X-ray CT high-density artefact suppression in cryosurgery," Phys.Med.Biol. 47[24]: N319-N326 (12-21-2002).
-
(2002)
Phys.Med.Biol.
, vol.47
, Issue.24
-
-
Wei, J.1
Sandison, G.A.2
Chen, L.3
Liang, Y.4
Xu, L.X.5
-
14
-
-
0034351113
-
X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses
-
S. Zhao, D. D. Robertson, G. Wang, B. Whiting, and K. T. Bae. "X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses," IEEE Trans.Med.Imaging 19[12]: 1238-1247 (2000).
-
(2000)
IEEE Trans.Med.Imaging
, vol.19
, Issue.12
, pp. 1238-1247
-
-
Zhao, S.1
Robertson, D.D.2
Wang, G.3
Whiting, B.4
Bae, K.T.5
-
15
-
-
0036680147
-
Flat-panel cone-beam computed tomography for image-guided radiation therapy
-
8-1
-
D. A. Jaffray, J. H. Siewerdsen, J. W. Wong, and A. A. Martinez. "Flat-panel cone-beam computed tomography for image-guided radiation therapy," Int.J.Radiat.Oncol.Biol.Phys. 53[5]: 1337-1349 (8-1-2002).
-
(2002)
Int.J.Radiat.Oncol.Biol.Phys.
, vol.53
, Issue.5
, pp. 1337-1349
-
-
Jaffray, D.A.1
Siewerdsen, J.H.2
Wong, J.W.3
Martinez, A.A.4
-
16
-
-
0033781494
-
Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
-
F. Noo, R. Clackdoyle, C. Mennessier, T. A. White, and T. J. Roney. "Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography," Phys.Med.Biol. 45[11]: 3489-3508 (2000).
-
(2000)
Phys.Med.Biol.
, vol.45
, Issue.11
, pp. 3489-3508
-
-
Noo, F.1
Clackdoyle, R.2
Mennessier, C.3
White, T.A.4
Roney, T.J.5
-
17
-
-
0021445363
-
Practical cone-beam algorithm
-
L. A. Feldkamp, L. C. Davis, and J. W. Kress. "Practical cone-beam algorithm," Journal of the Optical Society of America A: Optics, Image Science, and Vision 1[6]: 612-619 (1984).
-
(1984)
Journal of the Optical Society of America A: Optics, Image Science, and Vision
, vol.1
, Issue.6
, pp. 612-619
-
-
Feldkamp, L.A.1
Davis, L.C.2
Kress, J.W.3
-
18
-
-
33645201071
-
Geometric calibration of a cone-beam computed tomography system
-
in press
-
Y Cho, D. J. Moseley, J. H. Siewerdsen, and D. A. Jaffray. "Geometric calibration of a cone-beam computed tomography system," Med.Phys. in press (2005).
-
(2005)
Med.Phys.
-
-
Cho, Y.1
Moseley, D.J.2
Siewerdsen, J.H.3
Jaffray, D.A.4
-
19
-
-
0033954113
-
Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities
-
R. Fahrig and D. W. Holdsworth. "Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: image-based correction of gantry motion nonidealities," Med.Phys. 27[1]: 30-38 (2000).
-
(2000)
Med.Phys.
, vol.27
, Issue.1
, pp. 30-38
-
-
Fahrig, R.1
Holdsworth, D.W.2
|