2
-
-
0041374380
-
Measurement of the noise components in the medical X-ray intensity pattern due to overlaying, nonrecognizable structures
-
O Tischenko, C Hoeschen, O Effenberger, S Reissberg, E Buhr, W Döhring: Measurement of the noise components in the medical X-ray intensity pattern due to overlaying, nonrecognizable structures, Proceedings of SPIE 5030 (I), 422-432 (2003).
-
(2003)
Proceedings of SPIE
, vol.5030
, Issue.1
, pp. 422-432
-
-
Tischenko, O.1
Hoeschen, C.2
Effenberger, O.3
Reissberg, S.4
Buhr, E.5
Döhring, W.6
-
4
-
-
21244490063
-
Calculation of the properties of digital mammograms using a computer simulation
-
To be published in
-
RA Hunt, DR Dance, PR Bakic, ADA Maidment, M Sandborg, G Ullman, G Alm Carlsson: Calculation of the properties of digital mammograms using a computer simulation. To be published in Radiation Protection Dosimetry.
-
Radiation Protection Dosimetry
-
-
Hunt, R.A.1
Dance, D.R.2
Bakic, P.R.3
Maidment, A.D.A.4
Sandborg, M.5
Ullman, G.6
Carlsson, G.A.7
-
5
-
-
0036732640
-
Mammogram synthesis using a 3D simulation. II. Evaluation of synthetic mammogram texture
-
PR Bakic, M Albert, D Brzakovic, ADA Maidment: Mammogram synthesis using a 3D simulation. II. Evaluation of synthetic mammogram texture. Med. Phys. 29 (9), 2140-2151 (2002).
-
(2002)
Med. Phys.
, vol.29
, Issue.9
, pp. 2140-2151
-
-
Bakic, P.R.1
Albert, M.2
Brzakovic, D.3
Maidment, A.D.A.4
-
6
-
-
0032403613
-
Linear-systems modeling of parallel cascaded stochastic processes: The NFS of radiographic screens with reabsorption of characteristic x-radiation
-
I A Cunningham: Linear-systems modeling of parallel cascaded stochastic processes: the NFS of radiographic screens with reabsorption of characteristic x-radiation. SPIE 3326, 220-230 (1998).
-
(1998)
SPIE
, vol.3326
, pp. 220-230
-
-
Cunningham, I.A.1
-
7
-
-
0042860140
-
Detection in power-law noise: Spectrum exponents and CD diagram slopes
-
A E Burgess, P F Judy: Detection in power-law noise: spectrum exponents and CD diagram slopes. SPIE 5034, 57-62 (2003).
-
(2003)
SPIE
, vol.5034
, pp. 57-62
-
-
Burgess, A.E.1
Judy, P.F.2
-
8
-
-
0036033455
-
The importance of optimizing the image processing for different digital X-ray detectors to get as much information as possible from the radiographs
-
C Hoeschen, S Reissberg, W Döhring: The importance of Optimizing the Image Processing for Different Digital X-ray Detectors to Get as Much Information as Possible from the Radiographs. SPIE 4682, 828- 838 (2002)
-
(2002)
SPIE
, vol.4682
, pp. 828-838
-
-
Hoeschen, C.1
Reissberg, S.2
Döhring, W.3
-
9
-
-
23844555580
-
An artefact-free, structure-saving noise reduction method using the correlation between two images for threshold determination in the wavelet domain
-
to be published in the, conference on image processing
-
O Tischenko, C Hoeschen, E Buhr: An artefact-free, structure-saving noise reduction method using the correlation between two images for threshold determination in the wavelet domain, to be published in the proceedings SPIE "Medical Imaging 2005", conference on image processing.
-
Proceedings SPIE "Medical Imaging 2005"
-
-
Tischenko, O.1
Hoeschen, C.2
Buhr, E.3
-
11
-
-
3042546856
-
Measurement of the detective quantum efficiency (DQE) of digital x-ray imaging devices according to the forthcoming standard IEC 62220-1
-
H Illers, E Buhr, C Hoeschen, D Bergmann: Measurement of the detective quantum efficiency (DQE) of digital x-ray imaging devices according to the forthcoming standard IEC 62220-1, SPIE 5368, 177-87 (2004).
-
(2004)
SPIE
, vol.5368
, pp. 177-187
-
-
Illers, H.1
Buhr, E.2
Hoeschen, C.3
Bergmann, D.4
-
12
-
-
33645205162
-
Evaluation of a novel method of noise reduction using computer-simulated mammograms
-
To be published in
-
C Hoeschen, O Tischenko, D R Dance, R A Hunt, ADA Maidment, P R Bakic: Evaluation of a novel method of noise reduction using computer-simulated mammograms. To be published in Radiation Protection Dosimetry.
-
Radiation Protection Dosimetry
-
-
Hoeschen, C.1
Tischenko, O.2
Dance, D.R.3
Hunt, R.A.4
Maidment, A.D.A.5
Bakic, P.R.6
-
13
-
-
21244497816
-
A high-resolution voxel phantom of the breast for dose calculations in mammography
-
To be published in
-
C Hoeschen, U Fill, M Zankl, W Panzer, D Regulla, W Döhring: A high-resolution voxel phantom of the breast for dose calculations in mammography To be published in Radiation Protection Dosimetry.
-
Radiation Protection Dosimetry
-
-
Hoeschen, C.1
Fill, U.2
Zankl, M.3
Panzer, W.4
Regulla, D.5
Döhring, W.6
|