Volumn 5, Issue , 2004, Pages 2898-2902

A multilayer detector for PET based on APD arrays and continuous crystal elements

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; DATA REDUCTION; ELECTRIC POTENTIAL; GAMMA RAYS; OPTICAL COLLIMATORS; PHOTOMULTIPLIERS; SCINTILLATION;

EID: 23844510688     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (6)
  • 1
    • 0035428676 scopus 로고    scopus 로고
    • 4×8 APD array, consisting of two monolithic silicon wafers coupled to a 32-channel LSO matrix for high-resolution PET
    • Pichler B.J., Bernecker F, Boning G., Rafecas M. Pimpl M., Lorenz E. And Ziegler A 4×8 APD array, consisting of two monolithic silicon wafers coupled to a 32-channel LSO matrix for high-resolution PET. IEEE Trans. Nucl. Sci. 48(4) pp1391-1396, 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , Issue.4 , pp. 1391-1396
    • Pichler, B.J.1    Bernecker, F.2    Boning, G.3    Rafecas, M.4    Pimpl, M.5    Lorenz, E.6    Ziegler, A.7
  • 2
    • 0027998907 scopus 로고
    • High resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using Avalanche photodiode detectors
    • Marriott C.J., Cadorette J.E., Lecomte R., Scasnar V., Rousseau J. and van Lier J.E. High resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using Avalanche photodiode detectors.J. Nucl. med. 35(8), 1390-1396, 1994.
    • (1994) J. Nucl. Med. , vol.35 , Issue.8 , pp. 1390-1396
    • Marriott, C.J.1    Cadorette, J.E.2    Lecomte, R.3    Scasnar, V.4    Rousseau, J.5    Van Lier, J.E.6
  • 3
    • 0037151412 scopus 로고    scopus 로고
    • CMiCE: A high-resolution animal PET using continuous LSO with a statistics based positioning scheme
    • Aug
    • Joung J, Miyaoka RS, Lewellen TK cMiCE: a high-resolution animal PET using continuous LSO with a statistics based positioning scheme. Nucl. Instum. Meth. A 489 (1-3): pp584-598 Aug, 2002
    • (2002) Nucl. Instum. Meth. A , vol.489 , Issue.1-3 , pp. 584-598
    • Joung, J.1    Miyaoka, R.S.2    Lewellen, T.K.3
  • 4
    • 23844442251 scopus 로고    scopus 로고
    • Development of a Monte Carlo Simulation for APD based PET detectors using continuous scintillation crystal
    • Clowes P., McCallum S.J., and Welch A., Development of a Monte Carlo Simulation for APD based PET detectors using continuous scintillation crystal Proc. IEEE NSS-MIC M2-257, 2004.
    • (2004) Proc. IEEE NSS-MIC M2-257
    • Clowes, P.1    McCallum, S.J.2    Welch, A.3
  • 5
    • 3342876838 scopus 로고    scopus 로고
    • Properties of LYSO and recent LSO scintillators for phoswich PET detectors
    • Part 2 JUN
    • Pepin CM, Berard P, Perrot AL, Pepin C, Houde D, Lecomte R et al. Properties of LYSO and recent LSO scintillators for phoswich PET detectors. IEEE Trans. Nucl. Sci.51 (3): pp789-795 Part 2 JUN 2004
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.3 , pp. 789-795
    • Pepin, C.M.1    Berard, P.2    Perrot, A.L.3    Pepin, C.4    Houde, D.5    Lecomte, R.6
  • 6
    • 0035428527 scopus 로고    scopus 로고
    • Design and simulation of continuous scintillator with pixellated photodetector
    • Part 2 AUG
    • Takacs GJ, Rosenfeld AB, Lerch MLF Design and simulation of continuous scintillator with pixellated photodetector. IEEE Trans. Nucl Sci 48 (4): 1412-1417 Part 2 AUG 2001
    • (2001) IEEE Trans. Nucl Sci , vol.48 , Issue.4 , pp. 1412-1417
    • Takacs, G.J.1    Rosenfeld, A.B.2    Lerch, M.L.F.3