메뉴 건너뛰기




Volumn 4, Issue , 2004, Pages 2591-2595

Development of a Monte Carlo simulation for APD based PET detectors using continuous scintillation crystal

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; DATA ACQUISITION; MONTE CARLO METHODS; PHOTONS; POSITRON EMISSION TOMOGRAPHY; SCINTILLATION;

EID: 23844442251     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (7)
  • 1
    • 3342876838 scopus 로고    scopus 로고
    • Properties of LYSO and recent LSO scintillators for phoswich PET detectors
    • Part 2 JUN
    • Pepin CM, Berard P, Perrot AL, Pepin C, Houde D, Lecomte R et al. Properties of LYSO and recent LSO scintillators for phoswich PET detectors. IEEE Trans. Nucl. Sci.51 (3): pp789-795 Part 2 JUN 2004
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.3 , pp. 789-795
    • Pepin, C.M.1    Berard, P.2    Perrot, A.L.3    Pepin, C.4    Houde, D.5    Lecomte, R.6
  • 2
    • 23844510688 scopus 로고    scopus 로고
    • A multilayer detector for PET based on APD arrays and continuous crystal elements
    • McCallum S. J., Clowes P., and Welch A., A multilayer detector for PET based on APD arrays and continuous crystal elements. Proc. IEEE NSS-MIC M5-46, 2004.
    • (2004) Proc. IEEE NSS-MIC , vol.M5-46
    • McCallum, S.J.1    Clowes, P.2    Welch, A.3
  • 3
    • 0035428676 scopus 로고    scopus 로고
    • 4×8 APD array, consisting of two monolithic silicon wafers coupled to a 32-channel LSO matrix for high-resolution PET
    • Pichler B. J., Bernecker F, Boning G., Rafecas M. Pimpl M., Lorenz E. And Ziegler A 4×8 APD array, consisting of two monolithic silicon wafers coupled to a 32-channel LSO matrix for high-resolution PET. IEEE Trans. Nucl. Sci. 48(4) pp1391-1396, 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , Issue.4 , pp. 1391-1396
    • Pichler, B.J.1    Bernecker, F.2    Boning, G.3    Rafecas, M.4    Pimpl, M.5    Lorenz, E.6    Ziegler, A.7
  • 4
    • 0037151412 scopus 로고    scopus 로고
    • CMiCE: A high resolution animal PET using continuous LSO with a statistics based positioning scheme
    • Aug
    • Joung J, Miyaoka RS, Lewellen TK cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme. Nucl. Instum. Meth. A 489 (1-3): pp584-598 Aug, 2002
    • (2002) Nucl. Instum. Meth. A , vol.489 , Issue.1-3 , pp. 584-598
    • Joung, J.1    Miyaoka, R.S.2    Lewellen, T.K.3
  • 5
    • 0000727366 scopus 로고
    • Light collection scintillator detector composites for neutron devices
    • Knoll Gf, Knoll TF and Henderson TM, Light collection scintillator detector composites for neutron devices, IEEE Trans. Nucl. Sci. NS-35 pp872. 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.NS-35 , pp. 872
    • Knoll, G.F.1    Knoll, T.F.2    Henderson, T.M.3
  • 6
    • 0029519701 scopus 로고
    • A simulation to model position encoding multicrystal PET detectors
    • Tsang G, Moisan C and Rogers J.G. A simulation to model position encoding multicrystal PET detectors. IEEE Trans. Nucl. Sci. NS-42 pp2236, 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.NS-42 , pp. 2236
    • Tsang, G.1    Moisan, C.2    Rogers, J.G.3
  • 7
    • 0142148106 scopus 로고    scopus 로고
    • Simulation of the output from a scintillator/photodiode detector using Monte Carlo techniques and spice circuit simulation
    • Nov.
    • McCallum S.J., P.Clowes and Welch A.E. Simulation of the Output from a Scintillator/Photodiode Detector using Monte Carlo Techniques and Spice Circuit Simulation. Proc. IEEE NSS-MIC. M3-266 Nov. 2002
    • (2002) Proc. IEEE NSS-MIC. , vol.M3-266
    • McCallum, S.J.1    Clowes, P.2    Welch, A.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.