메뉴 건너뛰기




Volumn 236, Issue 3, 2005, Pages 1047-1052

Spin-labeling coronary MR angiography with steady-state free precession and radial k-space sampling: Initial results in healthy volunteers

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; ARTIFACT; CHI SQUARE TEST; CONTRAST TO NOISE RATIO; CORONARY ARTERY; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; IMAGING SYSTEM; INFORMED CONSENT; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; MATHEMATICAL PARAMETERS; MOTION; NORMAL HUMAN; PRIORITY JOURNAL; PROSPECTIVE STUDY; SAMPLING; SIGNAL NOISE RATIO; SPIN LABELING; SPIN LABELING CORONARY MAGNETIC RESONANCE ANGIOGRAPHY; STEADY STATE FREE PRECESSION; THREE DIMENSIONAL IMAGING; TIME; VOLUNTEER; WILCOXON SIGNED RANKS TEST;

EID: 23844506128     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2363040865     Document Type: Article
Times cited : (22)

References (31)
  • 1
    • 0035078828 scopus 로고    scopus 로고
    • Free-breathing black-blood coronary MR angiography: Initial results
    • Stuber M, Botnar RM, Kissinger KV, Manning WJ. Free-breathing black-blood coronary MR angiography: initial results. Radiology 2001;219:278-283.
    • (2001) Radiology , vol.219 , pp. 278-283
    • Stuber, M.1    Botnar, R.M.2    Kissinger, K.V.3    Manning, W.J.4
  • 2
    • 14944360212 scopus 로고    scopus 로고
    • Coronary magnetic resonance angiography for the detection of coronary stenoses
    • Kim WY, Danias PG, Stuber M, et al. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 2001;345:1863-1869.
    • (2001) N Engl J Med , vol.345 , pp. 1863-1869
    • Kim, W.Y.1    Danias, P.G.2    Stuber, M.3
  • 4
    • 0036235861 scopus 로고    scopus 로고
    • Three-dimensional true-FISP imaging of the coronary arteries: Improved contrast with T2-preparation
    • Shea SM, Deshpande VS, Chung YC, Li D. Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation. J Magn Reson Imaging 2002;15:597-602.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 597-602
    • Shea, S.M.1    Deshpande, V.S.2    Chung, Y.C.3    Li, D.4
  • 5
    • 0036828308 scopus 로고    scopus 로고
    • Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography
    • Spuentrup E, Bornert P, Botnar RM, Groen JP, Manning WJ, Stuber M. Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography. Invest Radiol 2002;37:637-642.
    • (2002) Invest Radiol , vol.37 , pp. 637-642
    • Spuentrup, E.1    Bornert, P.2    Botnar, R.M.3    Groen, J.P.4    Manning, W.J.5    Stuber, M.6
  • 6
    • 0036163569 scopus 로고    scopus 로고
    • Selective three-dimensional visualization of the coronary arterial lumen using arterial spin tagging
    • Stuber M, Bornert P, Spuentrup E, Botnar RM, Manning WJ. Selective three-dimensional visualization of the coronary arterial lumen using arterial spin tagging. Magn Reson Med 2002;47:322-329.
    • (2002) Magn Reson Med , vol.47 , pp. 322-329
    • Stuber, M.1    Bornert, P.2    Spuentrup, E.3    Botnar, R.M.4    Manning, W.J.5
  • 7
  • 8
    • 0025875174 scopus 로고
    • Coronary angiography using fast selective inversion recovery
    • Wang SJ, Hu BS, Macovski A, Nishimura DG. Coronary angiography using fast selective inversion recovery. Magn Reson Med 1991;18:417-423.
    • (1991) Magn Reson Med , vol.18 , pp. 417-423
    • Wang, S.J.1    Hu, B.S.2    Macovski, A.3    Nishimura, D.G.4
  • 9
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover GH, Pauly JM. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992;28:275-289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 10
    • 0242363327 scopus 로고    scopus 로고
    • Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling
    • Spuentrup E, Katoh M, Stuber M, et al. Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling. Rofo 2003;175: 1330-1334.
    • (2003) Rofo , vol.175 , pp. 1330-1334
    • Spuentrup, E.1    Katoh, M.2    Stuber, M.3
  • 11
    • 0031884958 scopus 로고    scopus 로고
    • Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T
    • Duerk JL, Lewin JS, Wendt M, Petersilge C. Remember true FISP? a high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T. J Magn Reson Imaging 1998;8:203-208.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 203-208
    • Duerk, J.L.1    Lewin, J.S.2    Wendt, M.3    Petersilge, C.4
  • 12
    • 0032873080 scopus 로고    scopus 로고
    • Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions
    • Fischer SE, Wickline SA, Lorenz CH. Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 1999;42:361-370.
    • (1999) Magn Reson Med , vol.42 , pp. 361-370
    • Fischer, S.E.1    Wickline, S.A.2    Lorenz, C.H.3
  • 13
    • 0032719272 scopus 로고    scopus 로고
    • Cardiac motion of coronary arteries: Variability in the rest period and implications for coronary MR angiography
    • Wang Y, Vidan E, Bergman GW. Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 1999;213:751-758.
    • (1999) Radiology , vol.213 , pp. 751-758
    • Wang, Y.1    Vidan, E.2    Bergman, G.W.3
  • 16
    • 11144358564 scopus 로고    scopus 로고
    • Free-breathing 3D steady-state free-precession coronary MR angiography with radial k-space sampling: Comparison with Cartesian k-space sampling and Cartesian gradient-echo coronary MR angiography - Pilot study
    • Spuentrup E, Katoh M, Buecker A, et al. Free-breathing 3D steady-state free-precession coronary MR angiography with radial k-space sampling: comparison with Cartesian k-space sampling and Cartesian gradient-echo coronary MR angiography - pilot study. Radiology 2004;231:581-586.
    • (2004) Radiology , vol.231 , pp. 581-586
    • Spuentrup, E.1    Katoh, M.2    Buecker, A.3
  • 18
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • Scheffler K, Lehnhardt S. Principles and applications of balanced SSFP techniques. Eur Radiol 2003;13:2409-2418.
    • (2003) Eur Radiol , vol.13 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 19
    • 0033594967 scopus 로고    scopus 로고
    • Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    • Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ. Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 1999;99:3139-3148.
    • (1999) Circulation , vol.99 , pp. 3139-3148
    • Botnar, R.M.1    Stuber, M.2    Danias, P.G.3    Kissinger, K.V.4    Manning, W.J.5
  • 20
    • 0031033998 scopus 로고    scopus 로고
    • Prospective adaptive navigator correction for breath-hold MR coronary angiography
    • McConnell MV, Khasgiwala VC, Savord BJ, et al. Prospective adaptive navigator correction for breath-hold MR coronary angiography. Magn Reson Med 1997;37:148-152.
    • (1997) Magn Reson Med , vol.37 , pp. 148-152
    • McConnell, M.V.1    Khasgiwala, V.C.2    Savord, B.J.3
  • 21
    • 0032810872 scopus 로고    scopus 로고
    • Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: Comparison of navigator locations
    • Stuber M, Botnar RM, Danias PG, Kissinger KV, Manning WJ. Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 1999;212:579-587.
    • (1999) Radiology , vol.212 , pp. 579-587
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3    Kissinger, K.V.4    Manning, W.J.5
  • 22
    • 0034877825 scopus 로고    scopus 로고
    • The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography
    • Spuentrup E, Stuber M, Botnar RM, Manning WJ. The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography. J Magn Reson Imaging 2001;14:311-318.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 311-318
    • Spuentrup, E.1    Stuber, M.2    Botnar, R.M.3    Manning, W.J.4
  • 23
    • 0032701253 scopus 로고    scopus 로고
    • Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography
    • Stuber M, Botnar RM, Danias PG, et al. Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. J Am Coll Cardiol 1999;34:524-531.
    • (1999) J Am Coll Cardiol , vol.34 , pp. 524-531
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3
  • 24
    • 33846926585 scopus 로고
    • Broadband nuclear magnetic resonance pulses with two-dimensional spatial selectivity
    • Hardy C, Cline HE. Broadband nuclear magnetic resonance pulses with two-dimensional spatial selectivity. J Appl Phys 1989;66:1513.
    • (1989) J Appl Phys , vol.66 , pp. 1513
    • Hardy, C.1    Cline, H.E.2
  • 25
    • 10144256538 scopus 로고    scopus 로고
    • Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction
    • Wang Y, Johnston DL, Breen JF, et al. Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction. Magn Reson Med 1996;36:551-556.
    • (1996) Magn Reson Med , vol.36 , pp. 551-556
    • Wang, Y.1    Johnston, D.L.2    Breen, J.F.3
  • 28
    • 0023735112 scopus 로고
    • Magnetic resonance angiography by selective inversion recovery using a compact gradient echo sequence
    • Nishimura DG, Macovski A, Jackson JI, Hu RS, Stevick CA, Axel L. Magnetic resonance angiography by selective inversion recovery using a compact gradient echo sequence. Magn Reson Med 1988;8:96-103.
    • (1988) Magn Reson Med , vol.8 , pp. 96-103
    • Nishimura, D.G.1    Macovski, A.2    Jackson, J.I.3    Hu, R.S.4    Stevick, C.A.5    Axel, L.6
  • 29
    • 0023678465 scopus 로고
    • Considerations of magnetic resonance angiography by selective inversion recovery
    • Nishimura DG, Macovski A, Pauly JM. Considerations of magnetic resonance angiography by selective inversion recovery. Magn Reson Med 1988;7:472-484.
    • (1988) Magn Reson Med , vol.7 , pp. 472-484
    • Nishimura, D.G.1    Macovski, A.2    Pauly, J.M.3
  • 30
    • 0028153930 scopus 로고
    • Signal targeting with alternating radiofrequency (STAR) sequences: Application to MR angiography
    • Edelman RR, Siewert B, Adamis M, Gaa J, Laub G, Wielopolski P. Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography. Magn Reson Med 1994;31:233-238.
    • (1994) Magn Reson Med , vol.31 , pp. 233-238
    • Edelman, R.R.1    Siewert, B.2    Adamis, M.3    Gaa, J.4    Laub, G.5    Wielopolski, P.6
  • 31
    • 0036828455 scopus 로고    scopus 로고
    • Renal arteries: Navigator-gated balanced fast field-echo projection MR angiography with aortic spin labeling: Initial experience
    • Spuentrup E, Manning WJ, Bornert P, Kissinger KV, Botnar RM, Stuber M. Renal arteries: navigator-gated balanced fast field-echo projection MR angiography with aortic spin labeling: initial experience. Radiology 2002;225:589-596.
    • (2002) Radiology , vol.225 , pp. 589-596
    • Spuentrup, E.1    Manning, W.J.2    Bornert, P.3    Kissinger, K.V.4    Botnar, R.M.5    Stuber, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.