Investigation of indoor climate and power usage in a data center

Author keywords

Airflow pattern; Data center; Indoor climate; IR camera; Power requirement; Thermal management; Visualization

Indexed keywords

AIR; AIR CONDITIONING; CLIMATE CHANGE; COOLING; ELECTRIC POWER SYSTEMS; HEATING; HOUSING; TEMPERATURE INDICATING CAMERAS; VENTILATION; VISUALIZATION;

EID: 23844482541     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2004.12.014     Document Type: Article
Times cited : (47)

References (14)
  • 1
    • 0037409656 scopus 로고    scopus 로고
    • Data center power requirements: Measurements from Silicon Valley
    • J. Mitchell-Jackson, J.G. Koomey, B. Nordman, and M. Blazek Data center power requirements: measurements from Silicon Valley Energy 28 8 2003 837 850
    • (2003) Energy , vol.28 , Issue.8 , pp. 837-850
    • Mitchell-Jackson, J.1    Koomey, J.G.2    Nordman, B.3    Blazek, M.4
  • 3
    • 4444332270 scopus 로고    scopus 로고
    • Heat density trends in data processing, computer systems, and telecommunications equipment
    • Santa Fe, NM, The Upsite Network
    • The Uptime Institute, Heat density trends in data processing, computer systems, and telecommunications equipment, White paper, Santa Fe, NM, The Upsite Network, 2000, http://www.upsite.com/TUIpages/whitepapers/tuiheat1.0.html.
    • (2000) White Paper
  • 4
    • 33645367497 scopus 로고    scopus 로고
    • Changing cooling requirements leave many data centers at risk
    • Santa Fe, NM, The Upsite Network
    • P.W. Turner, E.C. Koplin, Changing cooling requirements leave many data centers at risk, White paper, Santa Fe, NM, The Upsite Network, 2000, http://www.upsite.com/TUIpages/whitepapers/tuicooling.html.
    • (2000) White Paper
    • Turner, P.W.1    Koplin, E.C.2
  • 5
    • 0034301539 scopus 로고    scopus 로고
    • Improving cooling efficiency by increasing fan power usage
    • D.G. Wang, and P.K. Muller Improving cooling efficiency by increasing fan power usage Microelectronics Journal 31 9-10 2000 765 771
    • (2000) Microelectronics Journal , vol.31 , Issue.9-10 , pp. 765-771
    • Wang, D.G.1    Muller, P.K.2
  • 6
    • 77955284491 scopus 로고    scopus 로고
    • Effect of data center characteristics on data processing equipment inlet temperatures
    • July Kauai, Hawaii, USA
    • R.R. Schmidt, Effect of data center characteristics on data processing equipment inlet temperatures, in: Proceedings of IPACK'01, July 2001, Kauai, Hawaii, USA.
    • (2001) Proceedings of IPACK'01
    • Schmidt, R.R.1
  • 9
    • 29644434102 scopus 로고    scopus 로고
    • Mechanical packaging of HP's superdome server
    • 8-13 July 2001, Kauai, Hawaii, USA
    • M.D. Giraldo, Mechanical packaging of HP's superdome server, in: Proceedings of IPACK'01, 8-13 July 2001, Kauai, Hawaii, USA.
    • Proceedings of IPACK'01
    • Giraldo, M.D.1
  • 12
    • 0036680714 scopus 로고    scopus 로고
    • Measurement of air temperatures close to a low-velocity diffuser in displacement ventilation using an infrared camera
    • M. Cehlin, B. Moshfegh, and M. Sandberg Measurement of air temperatures close to a low-velocity diffuser in displacement ventilation using an infrared camera Energy and Buildings 34 7 2002 687 698
    • (2002) Energy and Buildings , vol.34 , Issue.7 , pp. 687-698
    • Cehlin, M.1    Moshfegh, B.2    Sandberg, M.3
  • 13
    • 0036462720 scopus 로고    scopus 로고
    • Infrared thermography for building diagnostics
    • C.A. Balaras, and A.A. Argiriou Infrared thermography for building diagnostics Energy and Buildings 34 2 2002 171 183
    • (2002) Energy and Buildings , vol.34 , Issue.2 , pp. 171-183
    • Balaras, C.A.1    Argiriou, A.A.2
  • 14
    • 0034197005 scopus 로고    scopus 로고
    • Heat gain from office equipment
    • C. Wilkins, and M.H. Hosni Heat gain from office equipment ASHRAE Journal 42 6 2000 33 44
    • (2000) ASHRAE Journal , vol.42 , Issue.6 , pp. 33-44
    • Wilkins, C.1    Hosni, M.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.