메뉴 건너뛰기




Volumn 7, Issue , 2004, Pages 4172-4176

Energy spectra and their calibration of four-layer DOI detector for brain PET scanner: JPET-D4

Author keywords

[No Author keywords available]

Indexed keywords

DETECTORS; GAMMA RAYS; IMAGING TECHNIQUES; LIGHT SCATTERING; PHOTOMULTIPLIERS; SCANNING; SENSITIVITY ANALYSIS; SINGLE CRYSTALS;

EID: 23844474004     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (11)
  • 2
    • 11844300375 scopus 로고    scopus 로고
    • Three dimensional array of scintillation crystals with proper reflector arrangement for a DOI detector
    • M7-114
    • N. Orita, H. Murayama, H. Kawai, et al., "Three dimensional array of scintillation crystals with proper reflector arrangement for a DOI detector", Conf. Rec. 2003 IEEE NSS & MIC, M7-114, 2003
    • (2003) Conf. Rec. 2003 IEEE NSS & MIC
    • Orita, N.1    Murayama, H.2    Kawai, H.3
  • 3
    • 0036624634 scopus 로고    scopus 로고
    • A depth of interaction detector for PET with GSO crystals doped with different amount of Ce
    • N. Inadama, H. Murayama, T. Omura, et al., "A depth of interaction detector for PET with GSO crystals doped with different amount of Ce", IEEE Trans. Nucl. Sci. Vol.49, No.3, 629-633, 2002
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.3 , pp. 629-633
    • Inadama, N.1    Murayama, H.2    Omura, T.3
  • 6
    • 33645197894 scopus 로고    scopus 로고
    • Calibration procedure for a DOI detector of high resolution PET through mixture Gaussian model
    • M8-5
    • E. Yoshida, Y. Kimura, K. Kitamura, H. Murayama, "Calibration procedure for a DOI detector of high resolution PET through mixture Gaussian model", 2003 IEEE NSS & MIC, M8-5, 2003
    • (2003) 2003 IEEE NSS & MIC
    • Yoshida, E.1    Kimura, Y.2    Kitamura, K.3    Murayama, H.4
  • 7
    • 0030167954 scopus 로고    scopus 로고
    • A study of inter-crystal scatter in small scintillator arrays designed for high resolution PET imaging
    • Y. Shao, S. R. Cherry, S. Siegel, R.W. Silverman, "A study of inter-crystal scatter in small scintillator arrays designed for high resolution PET imaging", IEEE Trans. Nucl. Sci. Vol.43, No.3, 1938-1944, 1996
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.3 , pp. 1938-1944
    • Shao, Y.1    Cherry, S.R.2    Siegel, S.3    Silverman, R.W.4
  • 8
    • 0034245271 scopus 로고    scopus 로고
    • Effect of detector scatter on the decoding accuracy of a DOI detector module
    • R.S. Miyaoka, T.K. Lewellen, "Effect of detector scatter on the decoding accuracy of a DOI detector module", IEEE Trans. Nucl. Sci., Vol 47, No. 4, 1614-1619, 2000
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , Issue.4 , pp. 1614-1619
    • Miyaoka, R.S.1    Lewellen, T.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.