메뉴 건너뛰기




Volumn 110, Issue 2, 2005, Pages 264-270

Composites: A novel alternative to construct solid state Ag/AgCl reference electrodes

Author keywords

Ag AgCl; Composite; FIA; Reference electrode; Solid state

Indexed keywords

COMPOSITE MATERIALS; GLASS; PARAMETER ESTIMATION; PH EFFECTS; RESINS; SATURATION (MATERIALS COMPOSITION); SILVER COMPOUNDS; TITRATION;

EID: 23844449779     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2005.02.013     Document Type: Article
Times cited : (24)

References (23)
  • 1
    • 0032732362 scopus 로고    scopus 로고
    • Microfabricated liquid junction Ag/AgCl reference electrode and its application to a One-Chip potentiometric sensor
    • H. Suzuki, H. Shiroishi, S. Sasaki, and I. Karube Microfabricated liquid junction Ag/AgCl reference electrode and its application to a One-Chip potentiometric sensor Anal. Chem. 71 1999 5069 5075
    • (1999) Anal. Chem. , vol.71 , pp. 5069-5075
    • Suzuki, H.1    Shiroishi, H.2    Sasaki, S.3    Karube, I.4
  • 4
    • 0030370019 scopus 로고    scopus 로고
    • Development of long-term stable reference electrode with fluoric resin liquid junction
    • S. Itoh, F. Kobayashi, K. Baba, Y. Asano, and H. Wada Development of long-term stable reference electrode with fluoric resin liquid junction Talanta 13 1996 135 145
    • (1996) Talanta , vol.13 , pp. 135-145
    • Itoh, S.1    Kobayashi, F.2    Baba, K.3    Asano, Y.4    Wada, H.5
  • 6
    • 0000720053 scopus 로고    scopus 로고
    • Fabrication and characterization of a solid state reference electrode for electroanalysis of natural water with ultramicroelectrodes
    • M.A. Nolan, S.H. Tan, and S.P. Kounaves Fabrication and characterization of a solid state reference electrode for electroanalysis of natural water with ultramicroelectrodes Anal. Chem. 69 1997 1244 1247
    • (1997) Anal. Chem. , vol.69 , pp. 1244-1247
    • Nolan, M.A.1    Tan, S.H.2    Kounaves, S.P.3
  • 8
    • 0141907968 scopus 로고    scopus 로고
    • Microfabricated potentiometric electrodes and their in vivo applications
    • E. Lindner Microfabricated potentiometric electrodes and their in vivo applications Anal. Chem. 2000 336A 345A
    • (2000) Anal. Chem.
    • Lindner, E.1
  • 9
    • 0006375503 scopus 로고    scopus 로고
    • Hydrophobic membranes as liquid junction-free reference electrodes
    • E. Bakker Hydrophobic membranes as liquid junction-free reference electrodes Electroanalysis 11 1999 788 791
    • (1999) Electroanalysis , vol.11 , pp. 788-791
    • Bakker, E.1
  • 10
    • 0347806276 scopus 로고    scopus 로고
    • Problems associated with the thin film Ag/AgCl reference electrode and a novel structure with improved durability
    • H. Suzuki, A. Hiratsuka, S. Sasaki, and I. Karube Problems associated with the thin film Ag/AgCl reference electrode and a novel structure with improved durability Sens. Actuators B 46 1998 104 113
    • (1998) Sens. Actuators B , vol.46 , pp. 104-113
    • Suzuki, H.1    Hiratsuka, A.2    Sasaki, S.3    Karube, I.4
  • 11
    • 0032136421 scopus 로고    scopus 로고
    • Solvent-processible polymer membrane-based liquid junction-free reference electrode
    • H.J. Lee, U.S. Hong, D.K. Lee, J.H. Shin, H. Nam, and G.S. Cha Solvent-processible polymer membrane-based liquid junction-free reference electrode Anal. Chem. 70 1998 3377 3383
    • (1998) Anal. Chem. , vol.70 , pp. 3377-3383
    • Lee, H.J.1    Hong, U.S.2    Lee, D.K.3    Shin, J.H.4    Nam, H.5    Cha, G.S.6
  • 12
    • 0036684947 scopus 로고    scopus 로고
    • Miniaturized reference electrodes based on Ag/AgiX internal reference elements. I. Manufacturing and performance
    • M. Ciobanu, J.P. Wilburn, N.I. Buss, P. Ditavong, and D.A. Lowry Miniaturized reference electrodes based on Ag/AgiX internal reference elements. I. Manufacturing and performance Electroanalysis 14 2002 989 997
    • (2002) Electroanalysis , vol.14 , pp. 989-997
    • Ciobanu, M.1    Wilburn, J.P.2    Buss, N.I.3    Ditavong, P.4    Lowry, D.A.5
  • 18
    • 0003073473 scopus 로고    scopus 로고
    • Solid state ion sensors with a liquid juntion-free polymer membrane-based reference electrode for blood analysis
    • H.J. Yoon, J.H. Shin, S.D. Lee, H. Nam, G.S. Cha, T.D. Strong, and R.B. Brown Solid state ion sensors with a liquid juntion-free polymer membrane-based reference electrode for blood analysis Sens. Actuators B 64 2000 8 14
    • (2000) Sens. Actuators B , vol.64 , pp. 8-14
    • Yoon, H.J.1    Shin, J.H.2    Lee, S.D.3    Nam, H.4    Cha, G.S.5    Strong, T.D.6    Brown, R.B.7
  • 19
    • 0000988796 scopus 로고    scopus 로고
    • Hydrophilic polyurethane coated silver/silver chloride electrode for the determination of chlorine in blood
    • J.S. Lee, S.D. Lee, G. Cui, H.J. Lee, J.H. Shin, G.S. Cha, and H. Nam Hydrophilic polyurethane coated silver/silver chloride electrode for the determination of chlorine in blood Electroanalysis 11 1999 260 267
    • (1999) Electroanalysis , vol.11 , pp. 260-267
    • Lee, J.S.1    Lee, S.D.2    Cui, G.3    Lee, H.J.4    Shin, J.H.5    Cha, G.S.6    Nam, H.7
  • 20
    • 0028394265 scopus 로고
    • Prevention of the rapid degradation of subcutaneously implanted Ag/AgCl reference electrodes using polymer coatings
    • F. Moussy, and D.J. Harrison Prevention of the rapid degradation of subcutaneously implanted Ag/AgCl reference electrodes using polymer coatings Anal. Chem. 66 1994 674 679
    • (1994) Anal. Chem. , vol.66 , pp. 674-679
    • Moussy, F.1    Harrison, D.J.2
  • 21
    • 85030876249 scopus 로고    scopus 로고
    • Development of a tubular biosensor for the determination of β-d-glucose
    • G. Álvarez, A. Rojas, A. Morales, and M.T. Ramírez Development of a tubular biosensor for the determination of β-d-glucose Bios. Bioelec. 19 2004 1057 1065
    • (2004) Bios. Bioelec. , vol.19 , pp. 1057-1065
    • Álvarez, G.1    Rojas, A.2    Morales, A.3    Ramírez, M.T.4
  • 23
    • 0000188150 scopus 로고
    • Flow through tubular PVC matrix membrane electrode without inner reference solution for flow injection analysis
    • S. Alegret, J. Alonso, J. Bartrolí, and J.M. Paulís Flow through tubular PVC matrix membrane electrode without inner reference solution for flow injection analysis Anal. Chim. Acta 164 1984 147 152
    • (1984) Anal. Chim. Acta , vol.164 , pp. 147-152
    • Alegret, S.1    Alonso, J.2    Bartrolí, J.3    Paulís, J.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.