메뉴 건너뛰기




Volumn 3, Issue , 2004, Pages 1742-1746

A new electronic set up for pulse shape method with large area planar silicon detector of CHIMERA

(41)  Alderighi, M a   Amorini, F b   Anzalone, A b   Arena, N b   Auditore, L c   Bassini, R f   Boiano, C f   Cardella, G b   Cavallaro, S b   Chatterjee, M B d   D'Andrea, M b   De Filippo, E b   Fichera, F b   Geraci, E e   Guardone, N b   Grimaldi, A b   Guazzoni, P f   La Guidara, E b   Lanzano G b   Lanzalone, G b   more..

a CNR   (Italy)

Author keywords

[No Author keywords available]

Indexed keywords

PARTICLE IDENTIFICATION; PULSE SHAPE DISCRIMINATION (PSD); TIME OF FLIGHT (TOF) MEASUREMENT; TIME RESOLUTION;

EID: 23844444513     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (11)
  • 2
    • 0028315823 scopus 로고
    • Particle identification in solid state detectors by means of pulse-shape analysis - Results of oomputersimulations
    • G. Pausch, W. Bohne, D. Hilscher, "Particle identification in solid state detectors by means of pulse-shape analysis - results of oomputersimulations", Nucl. Instr. Methods, vol. A337, (1994) 573-587.
    • (1994) Nucl. Instr. Methods , vol.A337 , pp. 573-587
    • Pausch, G.1    Bohne, W.2    Hilscher, D.3
  • 4
    • 8344290563 scopus 로고    scopus 로고
    • Wide-dynamic-range fast preamplifier for pulse shape analysis of signals from high-capacitance detectors
    • August
    • C. Boiano, R. Bassini, A. Pallia, Angelo Pagano, "Wide-Dynamic-Range Fast Preamplifier for Pulse Shape Analysis of Signals From High-Capacitance detectors", IEEE Trans. On Nucl. Sci. Vol. 51, No.4, August 2004
    • (2004) IEEE Trans. on Nucl. Sci. , vol.51 , Issue.4
    • Boiano, C.1    Bassini, R.2    Pallia, A.3    Pagano, A.4
  • 5
    • 4544221159 scopus 로고    scopus 로고
    • Charge and current-sensitive preamplifiers for pulse shape discrimination techniques with silicon detectors
    • H. Hamrita, E. Rauly, V. Blumenfeld, B.Borderie, M. Chabot, P. Edelbruck. et al., "Charge and current-sensitive preamplifiers for pulse shape discrimination techniques with silicon detectors", Nucl. Instrum. Meth. Vol. A 531(2004) 607-615
    • (2004) Nucl. Instrum. Meth. , vol.A 531 , pp. 607-615
    • Hamrita, H.1    Rauly, E.2    Blumenfeld, V.3    Borderie, B.4    Chabot, M.5    Edelbruck, P.6
  • 6
    • 85037661133 scopus 로고    scopus 로고
    • Fragmentation studies with the CHIMERA detector at LNS in Catania: Recent progress
    • A. Pagano, M. Alderighi, F. Amorini, A. Anzalone, N. Arena, L. Auditore, et al., "Fragmentation studies with the CHIMERA detector at LNS in Catania: recent progress", Nuclear Physics A734 (2004) 504-511
    • (2004) Nuclear Physics , vol.A734 , pp. 504-511
    • Pagano, A.1    Alderighi, M.2    Amorini, F.3    Anzalone, A.4    Arena, N.5    Auditore, L.6
  • 7
    • 0000569910 scopus 로고
    • Particle identification by pulse shape discrimination with p-i-n type semiconductor detector
    • C.A.J. Ammerlaan, R.F. Rumphorst, and L. A. Ch. Koerts, "Particle identification by pulse shape discrimination with p-i-n type semiconductor detector", Nucl. Instrum. Methods, vol. 22, pp. 189-200, 1963.
    • (1963) Nucl. Instrum. Methods , vol.22 , pp. 189-200
    • Ammerlaan, C.A.J.1    Rumphorst, R.F.2    Koerts, L.A.Ch.3
  • 8
    • 23844487467 scopus 로고    scopus 로고
    • Digital pulse-shape technique for charge discrimination in reversed chimera silicon detectors
    • see Paper contribution ID: 45397 in the Int. Conf. 18-25 Roma and references therein
    • M. Alderighi, F.Amorini, A. Anzalone, R. Bassini, C.Boiano, G.Cardella, S.Cavallaro, et al. ''Digital Pulse-Shape Technique for Charge Discrimination in Reversed CHIMERA Silicon Detectors", see Paper contribution ID: 45397 in the proceedings of IEEE-NSS, Int. Conf. 18-25, 2004 Roma and references therein
    • (2004) Proceedings of IEEE-NSS
    • Alderighi, M.1    Amorini, F.2    Anzalone, A.3    Bassini, R.4    Boiano, C.5    Cardella, G.6    Cavallaro, S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.