Volumn 63, Issue 4, 2005, Pages 385-395

Alpha 2 macroglobuline immunoturbidimetric assays (DakoCytomation reagents) on Roche Diagnostic analysers (Modular P, Cobas Integra). Application to FibroTest-ActiTest®;Dosage immunoturbidimétrique de l'alpha 2 macroglobuline (réactifs DakoCytomation) sur les automates Roche Diagnostics (Modujar P, Cobas Intégra). Application au FibroTest-ActiTest®

Author keywords

Alpha 2 macroglobuline; FibroTest ActiTesf ; Results transferability

Indexed keywords

ALPHA 2 MACROGLOBULIN;

EID: 23644442926     PISSN: 00033898     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (21)
  • 1
    • 0035820265 scopus 로고    scopus 로고
    • Biochemical markers of liver fibrosis in patients with hepatitis C virus infection : A prospective study
    • Imbert-Bismut F, Ratziu V, Pieroni L, Charlotte F, Benhamou Y, Poynard T. Biochemical markers of liver fibrosis in patients with hepatitis C virus infection : a prospective study. Lancet 2001 ; 357 : 1069-75.
    • (2001) Lancet , vol.357 , pp. 1069-1075
    • Imbert-Bismut, F.1    Ratziu, V.2    Pieroni, L.3    Charlotte, F.4    Benhamou, Y.5    Poynard, T.6
  • 2
    • 12344267742 scopus 로고    scopus 로고
    • Overview of the diagnostic value of biochemical markers of liver fibrosis (FibroTest®, HCV FibroSure) and necrosis (ActiTest) in patients with chronic hepatitis C
    • Poynard T, Imbert-Bismut F, Munteanu M, et al. Overview of the diagnostic value of biochemical markers of liver fibrosis (FibroTest®, HCV FibroSure) and necrosis (ActiTest) in patients with chronic hepatitis C. Comp Hepatol 2004 ; 3 : 8.
    • (2004) Comp Hepatol , vol.3 , pp. 8
    • Poynard, T.1    Imbert-Bismut, F.2    Munteanu, M.3
  • 3
    • 10744221863 scopus 로고    scopus 로고
    • Prediction of liver histological lesions with biochemical markers in patients with chronic hepatitis B
    • Myers PR, Tainturier MH, Ratziu V, et al. Prediction of liver histological lesions with biochemical markers in patients with chronic hepatitis B. J Hepatol 2003 ; 39 : 222-30.
    • (2003) J Hepatol , vol.39 , pp. 222-230
    • Myers, P.R.1    Tainturier, M.H.2    Ratziu, V.3
  • 4
    • 12344335496 scopus 로고    scopus 로고
    • Biomarkers for the prediction of liver fibrosis in patients with chronic alcoholic liver disease
    • Naveau S, Raynard B, Ratziu V, et al. Biomarkers for the prediction of liver fibrosis in patients with chronic alcoholic liver disease. Clin Gastroenterol Hepatol 2005 ; 3 : 167-74.
    • (2005) Clin Gastroenterol Hepatol , vol.3 , pp. 167-174
    • Naveau, S.1    Raynard, B.2    Ratziu, V.3
  • 5
    • 3242759346 scopus 로고    scopus 로고
    • Diagnostic value of biochemical markers (Fibrotest) for the prediction of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD)
    • abstract
    • Ratziu V, Lecalvez S, Imbert-Bismut F, et al. Diagnostic value of biochemical markers (Fibrotest) for the prediction of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). Hepatology 2003 ; 38 : 112A (abstract).
    • (2003) Hepatology , vol.38
    • Ratziu, V.1    Lecalvez, S.2    Imbert-Bismut, F.3
  • 6
    • 0028234491 scopus 로고
    • Intraobserver and interobserver variations in liver biopsy interpretation in patients with renal chronic hepatitis C
    • The French Metavir Co-operative Study Group. Intraobserver and interobserver variations in liver biopsy interpretation in patients with renal chronic hepatitis C. Hepatology 1994 ; 20: 15-20.
    • (1994) Hepatology , vol.20 , pp. 15-20
  • 7
    • 0042553522 scopus 로고    scopus 로고
    • A prospective assessment of inter-laboratory variability of biochemical fibrosis (FibroTest) and activity (ActiTest) in patients with chronic liver disease
    • Halfon P, Imbert-Bismut F, Messous D, et al. A prospective assessment of inter-laboratory variability of biochemical fibrosis (FibroTest) and activity (ActiTest) in patients with chronic liver disease. Comp Hepatol 2002 ; 1 : 3.
    • (2002) Comp Hepatol , vol.1 , pp. 3
    • Halfon, P.1    Imbert-Bismut, F.2    Messous, D.3
  • 8
    • 11144355931 scopus 로고    scopus 로고
    • Intra-laboratory analytical variability of biochemical markers of fibrosis (Fibrotest) and activity (Actitest) and reference ranges in healthy blood donors
    • Imbert-Bismut F, Messous D, Thibault V, et al. Intra-laboratory analytical variability of biochemical markers of fibrosis (Fibrotest) and activity (Actitest) and reference ranges in healthy blood donors. Clin Chem Lab Med 2004 ; 42 : 323-33.
    • (2004) Clin Chem Lab Med , vol.42 , pp. 323-333
    • Imbert-Bismut, F.1    Messous, D.2    Thibault, V.3
  • 9
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurement from two different analytical methods
    • Passing H, Bablok W. A new biometrical procedure for testing the equality of measurement from two different analytical methods. J Clin Chem Clin Biochem 1983 ; 21: 709-20.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 ; 1 : 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0032739052 scopus 로고    scopus 로고
    • Analyses de biologie médicale : Spécifications et normes d'acceptabilité à l'usage de la validation de techniques
    • Vassault A, Grafmeyer D, de Graeve J, Cohen R, Beaudonnet A, Bienvenu J. Analyses de biologie médicale : spécifications et normes d'acceptabilité à l'usage de la validation de techniques. Ann Biol Clin 1999 ; 57 : 685-95.
    • (1999) Ann Biol Clin , vol.57 , pp. 685-695
    • Vassault, A.1    Grafmeyer, D.2    De Graeve, J.3    Cohen, R.4    Beaudonnet, A.5    Bienvenu, J.6
  • 14
    • 1842835833 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase
    • Schuman G, Bonora R, Ceriotti F, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase. Clin Chem Lab Med 2002 ; 40 : 718-24.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 718-724
    • Schuman, G.1    Bonora, R.2    Ceriotti, F.3
  • 15
  • 16
    • 0003311125 scopus 로고
    • Modification of the Malloy-Evelyn method for a simple, reliable determination of total bilirubin in serum
    • Wahefeld AW, Herz G, Bernt E. Modification of the Malloy-Evelyn method for a simple, reliable determination of total bilirubin in serum. Scand J Clin Lab Invest 1972 ; 29 : 11-2.
    • (1972) Scand J Clin Lab Invest , vol.29 , pp. 11-12
    • Wahefeld, A.W.1    Herz, G.2    Bernt, E.3
  • 17
    • 0015667688 scopus 로고
    • Standardisation in bilirubin assays : Evaluation of selected methods and stability of bilirubin solutions
    • Doumas BT, Perry BN, Sasse EA, Straumfjord JR. Standardisation in bilirubin assays : evaluation of selected methods and stability of bilirubin solutions. Clin Chem 1973 ; 19 : 984-93.
    • (1973) Clin Chem , vol.19 , pp. 984-993
    • Doumas, B.T.1    Perry, B.N.2    Sasse, E.A.3    Straumfjord, J.R.4
  • 18
    • 3242798959 scopus 로고    scopus 로고
    • Prospective analysis of discordant results between biochemical markers and biopsy in patients with chronic hepatitis C
    • Poynard T, Munteanu M, Imbert-Bismut F, et al. Prospective analysis of discordant results between biochemical markers and biopsy in patients with chronic hepatitis C. Clin Chem 2004 ; 50 : 1344-55.
    • (2004) Clin Chem , vol.50 , pp. 1344-1355
    • Poynard, T.1    Munteanu, M.2    Imbert-Bismut, F.3
  • 20
    • 0035213207 scopus 로고    scopus 로고
    • Effect of certified reference material 470 (CRM 470) on national quality assurance programs for serum proteins in europe
    • Johnson AM, Whicher JT. Effect of certified reference material 470 (CRM 470) on national quality assurance programs for serum proteins in europe. Clin Chem Lab Med 2001 ; 39 : 1123-8.
    • (2001) Clin Chem Lab Med , vol.39 , pp. 1123-1128
    • Johnson, A.M.1    Whicher, J.T.2
  • 21
    • 33644572877 scopus 로고    scopus 로고
    • Directive 98/79/CE du parlement européen et du conseil du 27 octobre 1998, relative aux « dispositifs médicaux de diagnostic in vivo »
    • Directive 98/79/CE du parlement européen et du conseil du 27 octobre 1998, relative aux « dispositifs médicaux de diagnostic in vivo ». Journal officiel des Communautés européennes 7.12.98, L. 331-3.
    • Journal Officiel des Communautés Européennes 7.12.98, L. , pp. 331-333