메뉴 건너뛰기




Volumn 42, Issue 3, 2004, Pages 323-333

Intra-laboratory analytical variability of biochemical markers of fibrosis (Fibrotest) and activity (Actitest) and reference ranges in healthy blood donors

Author keywords

Assay standardization; Enzyme calibration; Liver fibrosis markers; Reference ranges; Result transferability; Test combinations

Indexed keywords

ALANINE AMINOTRANSFERASE; ALPHA 2 MACROGLOBULIN; APOLIPOPROTEIN A1; BILIRUBIN; BIOCHEMICAL MARKER; GAMMA GLUTAMYLTRANSFERASE; HAPTOGLOBIN;

EID: 11144355931     PISSN: 14346621     EISSN: None     Source Type: Journal    
DOI: 10.1515/CCLM.2004.058     Document Type: Article
Times cited : (127)

References (64)
  • 1
    • 0025119535 scopus 로고
    • A 21-year experience with major hemorrhage after percutaneous liver biopsy
    • McGill DB, Rakela J, Zinsmeister AR, Ott BJ. A 21-year experience with major hemorrhage after percutaneous liver biopsy. Gastroenterology 1990;99:1396-400.
    • (1990) Gastroenterology , vol.99 , pp. 1396-1400
    • McGill, D.B.1    Rakela, J.2    Zinsmeister, A.R.3    Ott, B.J.4
  • 3
    • 0033849619 scopus 로고    scopus 로고
    • Practices of liver biopsy in France: Results of a prospective nationwide survey
    • For the Group of Epidemiology of the French Association for the Study of the liver (AFEF)
    • Cadranel JF, Rufat P, Degos F. Practices of liver biopsy in France: results of a prospective nationwide survey. For the Group of Epidemiology of the French Association for the Study of the liver (AFEF), Hepatology 2000;32:477-81.
    • (2000) Hepatology , vol.32 , pp. 477-481
    • Cadranel, J.F.1    Rufat, P.2    Degos, F.3
  • 4
    • 0022656928 scopus 로고
    • Sampling variability and its influence on the diagnostic yield of percutaneous biopsy of the liver
    • Maharaj B, Maharaj RJ, Leary WP, Cooppan RM, Naran AD, Pirie D, et al. Sampling variability and its influence on the diagnostic yield of percutaneous biopsy of the liver. Lancet 1986;8480:523-5.
    • (1986) Lancet , vol.8480 , pp. 523-525
    • Maharaj, B.1    Maharaj, R.J.2    Leary, W.P.3    Cooppan, R.M.4    Naran, A.D.5    Pirie, D.6
  • 5
    • 0002273703 scopus 로고    scopus 로고
    • Hepatic fibrosis: Are any of the serum markers useful?
    • Oh S, Afdhal NH. Hepatic fibrosis: are any of the serum markers useful? Curr Gastroenterol Rep 2001;3:12-8.
    • (2001) Curr. Gastroenterol. Rep. , vol.3 , pp. 12-18
    • Oh, S.1    Afdhal, N.H.2
  • 6
    • 0029879030 scopus 로고    scopus 로고
    • Diagnostic accuracy of hyaluronan and type III procollagen amino-terminal peptide serum assays as markers of liver fibrosis in chronic viral hepatitis C evaluated by ROC curve analysis
    • Guechot J, Laudat A, Loria A, Serfaty L, Poupon R, Giboudeau J. Diagnostic accuracy of hyaluronan and type III procollagen amino-terminal peptide serum assays as markers of liver fibrosis in chronic viral hepatitis C evaluated by ROC curve analysis. Clin Chem 1996;42:558-63.
    • (1996) Clin. Chem. , vol.42 , pp. 558-563
    • Guechot, J.1    Laudat, A.2    Loria, A.3    Serfaty, L.4    Poupon, R.5    Giboudeau, J.6
  • 7
    • 0036829982 scopus 로고    scopus 로고
    • Noninvasive monitoring of patients with chronic hepatitis C
    • Fontana RJ, Lok ASF. Noninvasive monitoring of patients with chronic hepatitis C. Hepatology 2002;36:Suppl.1:557-64.
    • (2002) Hepatology , vol.36 , Issue.SUPPL. , pp. 557-564
    • Fontana, R.J.1    Lok, A.S.F.2
  • 8
    • 0035986081 scopus 로고    scopus 로고
    • Matrix metalloproteinase-9 and tissue inhibitors of matrix metalloproteinase-1 in plasma of patients ci-infected with HCV and HIV
    • Mastroianni CM, Liuzzi GM, D'Ettorre G, Lichtner M, Forcina G, Di Campli NF, et al. Matrix metalloproteinase-9 and tissue inhibitors of matrix metalloproteinase-1 in plasma of patients ci-infected with HCV and HIV. HIV Clin Trials 2002;3:310-5.
    • (2002) HIV Clin. Trials , vol.3 , pp. 310-315
    • Mastroianni, C.M.1    Liuzzi, G.M.2    D'Ettorre, G.3    Lichtner, M.4    Forcina, G.5    Di Campli, N.F.6
  • 9
    • 0036135242 scopus 로고    scopus 로고
    • Diagnostic potential of circulating TIMP-1 and MMP-2 as markers of liver fibrosis in patients with chronic hepatitis C
    • Boeker KH, Haberkorn CI, Michels D, Flemming P, Manns MP, Lichtinghagen R. Diagnostic potential of circulating TIMP-1 and MMP-2 as markers of liver fibrosis in patients with chronic hepatitis C. Clin Chim Acta 2002;316:71-81.
    • (2002) Clin. Chim. Acta , vol.316 , pp. 71-81
    • Boeker, K.H.1    Haberkorn, C.I.2    Michels, D.3    Flemming, P.4    Manns, M.P.5    Lichtinghagen, R.6
  • 11
    • 0036789328 scopus 로고    scopus 로고
    • Identification of chronic hepatitis C patients without hepatic fibrosis by a simple predictive model
    • Forns X, Ampurdanes S, Llovet JM, Aponte J, Quinto L, Martinez-Bauer E, et al. Identification of chronic hepatitis C patients without hepatic fibrosis by a simple predictive model. Hepatology 2002;36:986-92.
    • (2002) Hepatology , vol.36 , pp. 986-992
    • Forns, X.1    Ampurdanes, S.2    Llovet, J.M.3    Aponte, J.4    Quinto, L.5    Martinez-Bauer, E.6
  • 12
    • 0028234491 scopus 로고
    • Intraobserver and interobserver variations in liver biopsy interpretation in patients with chronic hepatitis C
    • The French METAVIR Cooperative Study Group
    • The French METAVIR Cooperative Study Group. Intraobserver and interobserver variations in liver biopsy interpretation in patients with chronic hepatitis C. Hepatology 1994;20:15-20.
    • (1994) Hepatology , vol.20 , pp. 15-20
  • 13
    • 0035820265 scopus 로고    scopus 로고
    • Biochemical markers of liver fibrosis in patients with hepatitis C virus infections: A prospective study
    • Imbert-Bismut F, Ratziu V, Pieroni L, Charlotte F, Benhamou Y, Poynard T. Biochemical markers of liver fibrosis in patients with hepatitis C virus infections: a prospective study. Lancet 2001;357:1069-75.
    • (2001) Lancet , vol.357 , pp. 1069-1075
    • Imbert-Bismut, F.1    Ratziu, V.2    Pieroni, L.3    Charlotte, F.4    Benhamou, Y.5    Poynard, T.6
  • 14
    • 0036906034 scopus 로고    scopus 로고
    • Biochemical markers of liver cirrhosis in patients infected by hepatitis C virus: Longitudinal validation in a randomized trial
    • The GERMED cyt-04 group
    • Poynard T, Imbert-Bismut F, Ratziu V, Chevret S, Jardel C, Moussali J, et al. Biochemical markers of liver cirrhosis in patients infected by hepatitis C virus: longitudinal validation in a randomized trial. The GERMED cyt-04 group. J Viral Hepat 2002;9:128-33.
    • (2002) J. Viral Hepat. , vol.9 , pp. 128-133
    • Poynard, T.1    Imbert-Bismut, F.2    Ratziu, V.3    Chevret, S.4    Jardel, C.5    Moussali, J.6
  • 15
    • 1842825764 scopus 로고    scopus 로고
    • Serum biochemical markers accurately predict liver fibrosis in HIV and hepatitis C virus-coinfected patients
    • Myers RP, Benhamou Y, Imbert-Bismut F, Thibault V, Bochet M, Charlotte F, et al. Serum biochemical markers accurately predict liver fibrosis in HIV and hepatitis C virus-coinfected patients. AIDS 2002.
    • (2002) AIDS
    • Myers, R.P.1    Benhamou, Y.2    Imbert-Bismut, F.3    Thibault, V.4    Bochet, M.5    Charlotte, F.6
  • 16
    • 1842775434 scopus 로고    scopus 로고
    • Life is possible without biopsy in patients with chronic hepatitis C: Validation of biochemical markers of liver fibrosis and activity in 1570 patients and blood donors
    • [abstract] AASLD Boston
    • Myers RP, Messous D, Thabut D, Imbert-Bismut F, Ratziu V, Mercadier A, et al. Life is possible without biopsy in patients with chronic hepatitis C: validation of biochemical markers of liver fibrosis and activity in 1570 patients and blood donors [abstract]. AASLD Boston 2002.
    • (2002)
    • Myers, R.P.1    Messous, D.2    Thabut, D.3    Imbert-Bismut, F.4    Ratziu, V.5    Mercadier, A.6
  • 17
    • 0042121183 scopus 로고    scopus 로고
    • Biochemical markers as surrogate markers of liver fibrosis and activity in patients infected by hepatitis C virus: An example in a randomized trial of pegylated interferon alfa-2b and ribavirin combination
    • [abstract]
    • Poynard T, McHutchison J, Manns M, Myers RP, Albrecht J. Biochemical markers as surrogate markers of liver fibrosis and activity in patients infected by hepatitis C virus: an example in a randomized trial of pegylated interferon alfa-2b and ribavirin combination [abstract]. Hepatology 2002;36:351A.
    • (2002) Hepatology , vol.36
    • Poynard, T.1    McHutchison, J.2    Manns, M.3    Myers, R.P.4    Albrecht, J.5
  • 18
    • 0037471273 scopus 로고    scopus 로고
    • Serum biochemical markers accurately predict liver fibrosis in HIV and hepatitis C virus-coinfected patients
    • Myers RP, Benhamou Y, Imbert-Bismut F, Bochet M, Thibaut V, Ratziu V, et al. Serum biochemical markers accurately predict liver fibrosis in HIV and hepatitis C virus-coinfected patients. AIDS 2003;17:721-5.
    • (2003) AIDS , vol.17 , pp. 721-725
    • Myers, R.P.1    Benhamou, Y.2    Imbert-Bismut, F.3    Bochet, M.4    Thibaut, V.5    Ratziu, V.6
  • 19
    • 0043123089 scopus 로고    scopus 로고
    • The prediction of fibrosis with serum biochemical markers in patients with chronic hepatitis C: Prospective validation in 534 patients
    • [abstract]
    • Myers RP, Messous D, Thabut D, Imbert-Bismut F, Ratziu V, Mercadier A, et al. The prediction of fibrosis with serum biochemical markers in patients with chronic hepatitis C: prospective validation in 534 patients [abstract]. Hepatology 2002;36:351A.
    • (2002) Hepatology , vol.36
    • Myers, R.P.1    Messous, D.2    Thabut, D.3    Imbert-Bismut, F.4    Ratziu, V.5    Mercadier, A.6
  • 20
    • 0031693804 scopus 로고    scopus 로고
    • Rat hepatic stellate cell expression of α2-macroglobulin is a feature of cellular activation: Implications for matrix remodelling in hepatic fibrosis
    • Kawser CA, Iredale JP, Winwood PJ, Arthur MJP. Rat hepatic stellate cell expression of α2-macroglobulin is a feature of cellular activation: implications for matrix remodelling in hepatic fibrosis. Clin Sci 1998;95:179-86.
    • (1998) Clin. Sci. , vol.95 , pp. 179-186
    • Kawser, C.A.1    Iredale, J.P.2    Winwood, P.J.3    Arthur, M.J.P.4
  • 21
    • 0030795961 scopus 로고    scopus 로고
    • Transforming growth factor-beta-induced collagen synthesis by human liver myofibroblasts is inhibited by alpha2-macroglobulin
    • Tiggelman AM, Linthorst C, Boers W, Brand HS, Chamuleau RA. Transforming growth factor-beta-induced collagen synthesis by human liver myofibroblasts is inhibited by alpha2-macroglobulin. J Hepatol 1997;26:1220-8.
    • (1997) J. Hepatol. , vol.26 , pp. 1220-1228
    • Tiggelman, A.M.1    Linthorst, C.2    Boers, W.3    Brand, H.S.4    Chamuleau, R.A.5
  • 24
    • 0025870336 scopus 로고
    • A simple biological index for detection of alcoholic liver disease in drinkers
    • Poynard T, Aubert A, Bedossa P, Abella A, Naveau S, Paraf F, et al. A simple biological index for detection of alcoholic liver disease in drinkers. Gastroenterology 1991;100:1397-402.
    • (1991) Gastroenterology , vol.100 , pp. 1397-1402
    • Poynard, T.1    Aubert, A.2    Bedossa, P.3    Abella, A.4    Naveau, S.5    Paraf, F.6
  • 25
    • 0034744631 scopus 로고    scopus 로고
    • Increased levels of gammaGT suggest the presence of bile duct lesions in patients with chronic hepatitis C: Absence of influence of HCV genotype, HCV-RNA serum levels, and HGV infection on this histological damage
    • Giannini E, Botta F, Fasoli A, Romagnoli P, Mastracci L, Ceppa P, et al. Increased levels of gammaGT suggest the presence of bile duct lesions in patients with chronic hepatitis C: absence of influence of HCV genotype, HCV-RNA serum levels, and HGV infection on this histological damage. Dig Dis Sci 2001;46:524-9.
    • (2001) Dig. Dis. Sci. , vol.46 , pp. 524-529
    • Giannini, E.1    Botta, F.2    Fasoli, A.3    Romagnoli, P.4    Mastracci, L.5    Ceppa, P.6
  • 26
    • 0023640768 scopus 로고
    • Modulation of gamma-glutamyltranspeptidase in normal rat hepatocytes in culture by cell density, epidermal growth factor and agents which alter cell differentiation
    • Edwards AM, Lucas CM, Baddams HM. Modulation of gamma-glutamyltranspeptidase in normal rat hepatocytes in culture by cell density, epidermal growth factor and agents which alter cell differentiation. Carcinogenesis 1987;8:1837-42.
    • (1987) Carcinogenesis , vol.8 , pp. 1837-1842
    • Edwards, A.M.1    Lucas, C.M.2    Baddams, H.M.3
  • 27
    • 0030157924 scopus 로고    scopus 로고
    • Role of liver extracellular matrix in transcriptional and post-transcriptional regulation of apolipoprotein A-1 by hepatocytes
    • Paradis V, Laurent A, Mathurin P, Poynard T, Vidaud D, Bedossa P. Role of liver extracellular matrix in transcriptional and post-transcriptional regulation of apolipoprotein A-1 by hepatocytes. Cell Mol Biol 1996;42:525-34.
    • (1996) Cell. Mol. Biol. , vol.42 , pp. 525-534
    • Paradis, V.1    Laurent, A.2    Mathurin, P.3    Poynard, T.4    Vidaud, D.5    Bedossa, P.6
  • 28
    • 0034720287 scopus 로고    scopus 로고
    • Evaluation of abnormal liver-enzyme results in asymptomatic patients
    • Pratt DS, Kaplan MM. Evaluation of abnormal liver-enzyme results in asymptomatic patients. N Engl J Med 2000;342:1266-71.
    • (2000) N. Engl. J. Med. , vol.342 , pp. 1266-1271
    • Pratt, D.S.1    Kaplan, M.M.2
  • 29
    • 0029796235 scopus 로고    scopus 로고
    • Diagnostic approach to liver enzyme elevation
    • Craxi A, Almasio P. Diagnostic approach to liver enzyme elevation. J Hepatol 1996;25:45-51.
    • (1996) J. Hepatol. , vol.25 , pp. 45-51
    • Craxi, A.1    Almasio, P.2
  • 30
    • 1842835833 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase [L-alanine:2-oxoglutarate aminotransferase (ALT , EC 2.6.1.2]
    • Schumann G, Bonora R, Ceriotti F, Ferard G, Ferrero CA, Franck PFH, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase [L-alanine:2-oxoglutarate aminotransferase (ALT), EC 2.6.1.2]. Clin Chem Lab Med 2002;40:718-24.
    • (2002) Clin. Chem. Lab. Med. , vol.40 , pp. 718-724
    • Schumann, G.1    Bonora, R.2    Ceriotti, F.3    Ferard, G.4    Ferrero, C.A.5    Franck, P.F.H.6
  • 32
    • 0003311125 scopus 로고
    • Modification of the Malloy-Evelyn method for a simple, reliable determination of total bilirubin in serum
    • [abstract] [abstract 11-12]
    • Wahefeld AW, Herz G, Bernt E. Modification of the Malloy-Evelyn method for a simple, reliable determination of total bilirubin in serum [abstract]. Scand J Clin Lab Invest 1972;29 [abstract 11-12].
    • (1972) Scand. J. Clin. Lab. Invest. , vol.29
    • Wahefeld, A.W.1    Herz, G.2    Bernt, E.3
  • 33
    • 0015667688 scopus 로고
    • Standardizationin bilirubin assays: Evaluation of selected methods and stability of bilirubin solutions
    • Doumas BT, Perry BN, Sasse EA, Straumfjord JV Jr. Standardization in bilirubin assays: evaluation of selected methods and stability of bilirubin solutions. Clin Chem 1973;19:984-93.
    • (1973) Clin. Chem. , vol.19 , pp. 984-993
    • Doumas, B.T.1    Perry, B.N.2    Sasse, E.A.3    Straumfjord Jr., J.V.4
  • 34
    • 0030035470 scopus 로고    scopus 로고
    • Consensus of a group of professional societies and diagnostic companies for interim reference ranges for 14 proteins in serum based on the standardization against the IFCC/BCR/CAP Reference Material (CRM470). International Federation of Clinical Chemistry
    • Community Bureau of Reference of the Commission of the European Communities. College of American Pathologists
    • Dati F, Schumann G, Thomas L, Aguzzi F, Baudner S, Bienvenu J, et al. Consensus of a group of professional societies and diagnostic companies for interim reference ranges for 14 proteins in serum based on the standardization against the IFCC/BCR/CAP Reference Material (CRM470). International Federation of Clinical Chemistry. Community Bureau of Reference of the Commission of the European Communities. College of American Pathologists. Eur J Clin Chem Clin Biochem 1996;34:517-20.
    • (1996) Eur. J. Clin. Chem. Clin. Biochem. , vol.34 , pp. 517-520
    • Dati, F.1    Schumann, G.2    Thomas, L.3    Aguzzi, F.4    Baudner, S.5    Bienvenu, J.6
  • 35
    • 0026741679 scopus 로고
    • International Federation of Clinical Chemistry Standardization Project for Measurement of Apolipoproteins A1 and B. II Evaluation and selection of candidate reference materials
    • Albers JJ, Marcovina SM, Kennedy H. International Federation of Clinical Chemistry Standardization Project for Measurement of Apolipoproteins A1 and B. II Evaluation and selection of candidate reference materials. Clin Chem 1992;38:658-62.
    • (1992) Clin. Chem. , vol.38 , pp. 658-662
    • Albers, J.J.1    Marcovina, S.M.2    Kennedy, H.3
  • 36
    • 0001068517 scopus 로고
    • Commission "For Validation of Methods" of the Societé Française de Biologie Clinique. Protocol for the validation of methods (document B, stage 3)
    • Vassault A, Grafmeyer, D, Naudin C, Dumont G, Bailly M, Henny J, et al. Commission "For Validation of Methods" of the Societé Française de Biologie Clinique. Protocol for the validation of methods (document B, stage 3). Ann Biol Clin 1986;44:696-747.
    • (1986) Ann. Biol. Clin. , vol.44 , pp. 696-747
    • Vassault, A.1    Grafmeyer, D.2    Naudin, C.3    Dumont, G.4    Bailly, M.5    Henny, J.6
  • 37
    • 0027060563 scopus 로고
    • Comission Validation de Techniques de la SFBC et groupe de travail SFBC/Corata "Comparaison de Techniques". Recommandations pour la comparaison de techniques
    • Vassault A, Baud M, Castagnier M, Dumont G, Ingrand J, Mercier M, et al. Comission Validation de Techniques de la SFBC et groupe de travail SFBC/Corata "Comparaison de Techniques". Recommandations pour la comparaison de techniques. Ann Biol Clin 1992;50:727-30.
    • (1992) Ann. Biol. Clin. , vol.50 , pp. 727-730
    • Vassault, A.1    Baud, M.2    Castagnier, M.3    Dumont, G.4    Ingrand, J.5    Mercier, M.6
  • 38
    • 0032739052 scopus 로고    scopus 로고
    • Analyses de biologie médicale: spécifications et normes d'acceptabilité à l'usage de la validation de techniques
    • Vassault A, Grafmeyer D, de Graeve J, Cohen R, Beaudonnet A, Bienvenu J. Analyses de biologie médicale: spécifications et normes d'acceptabilité à l'usage de la validation de techniques. Ann Biol Clin 1999;57:685-95.
    • (1999) Ann. Biol. Clin. , vol.57 , pp. 685-695
    • Vassault, A.1    Grafmeyer, D.2    de Graeve, J.3    Cohen, R.4    Beaudonnet, A.5    Bienvenu, J.6
  • 39
    • 0003547060 scopus 로고    scopus 로고
    • Evaluation of precision performance of clinical chemistry devices; approved guideline
    • National Committee for Clinical Laboratory Standards. NCCLS guideline EP5-A, Wayne, PA:NCCLS, February
    • National Committee for Clinical Laboratory Standards. Evaluation of precision performance of clinical chemistry devices; approved guideline. NCCLS guideline EP5-A, Wayne, PA:NCCLS, February 1999.
    • (1999)
  • 40
    • 0000087642 scopus 로고
    • The determination of bilirubin with photoelectric colorimeter
    • Malloy HT, Evelyn KA. The determination of bilirubin with photoelectric colorimeter. J Biol Chem 1937;19:984-93.
    • (1937) J. Biol. Chem. , vol.19 , pp. 984-993
    • Malloy, H.T.1    Evelyn, K.A.2
  • 41
    • 0003100676 scopus 로고
    • Vereinfachte Photometrische Methoden zur Bestimmung des Blutbilirubins
    • Jendrassik Grof
    • Jendrassik Grof. Vereinfachte Photometrische Methoden zur Bestimmung des Blutbilirubins. Biochem Z 1938;297:81-9.
    • (1938) Biochem. Z , vol.297 , pp. 81-89
  • 43
    • 0027414009 scopus 로고
    • Evaluation of regression procedures for methods comparison studies based on regression analysis
    • Linnet K. Evaluation of regression procedures for methods comparison studies based on regression analysis. Clin Chem 1993;39:424-32.
    • (1993) Clin. Chem. , vol.39 , pp. 424-432
    • Linnet, K.1
  • 44
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurement from two different analytical methods
    • Passing H, Bablok W. A new biometrical procedure for testing the equality of measurement from two different analytical methods. J Clin Chem Clin Biochem 1983;21:709-20.
    • (1983) J. Clin. Chem. Clin. Biochem. , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 45
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis RJ, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159-64.
    • (1977) Biometrics , vol.33 , pp. 159-164
    • Landis, R.J.1    Koch, G.G.2
  • 46
    • 0037371363 scopus 로고    scopus 로고
    • Validation of the FibroTest biochemical markers score in assessing liver fibrosis in hepatitis C patients
    • Rossi E, Adam L, Prins A, Bulsara M, De Boer B, Garas G, et al. Validation of the FibroTest biochemical markers score in assessing liver fibrosis in hepatitis C patients. Clin Chem 2003;49:450-4.
    • (2003) Clin. Chem. , vol.49 , pp. 450-454
    • Rossi, E.1    Adam, L.2    Prins, A.3    Bulsara, M.4    De Boer, B.5    Garas, G.6
  • 47
    • 0141480785 scopus 로고    scopus 로고
    • Fibrotest even better than liver biopsy?
    • [electronic letter] Response (March 21, 2003)
    • Poynard T, Imbert-Bismut F, Ratziu V, Myers RP, Di-Martino V, Thabut D, et al. Fibrotest even better than liver biopsy? [electronic letter] Clin Chem 2003. http://www.clinchem.org/cgi/eletters/49/3/450. Response (March 21, 2003).
    • (2003) Clin. Chem.
    • Poynard, T.1    Imbert-Bismut, F.2    Ratziu, V.3    Myers, R.P.4    Di-Martino, V.5    Thabut, D.6
  • 48
    • 0042553522 scopus 로고    scopus 로고
    • A prospective assessment of the inter-laboratory variability of biochemical markers of fibrosis (FibroTest) and Activity (ActiTest) in patients with chronic liver disease
    • Halfon P, Imbert-Bismut F, Messous D, Antoniotti G, Benchetrit D, Cart-Lamy P, et al. A prospective assessment of the inter-laboratory variability of biochemical markers of fibrosis (FibroTest) and Activity (ActiTest) in patients with chronic liver disease. Comp Hepatol 2002;1:3.
    • (2002) Comp. Hepatol. , vol.1 , pp. 3
    • Halfon, P.1    Imbert-Bismut, F.2    Messous, D.3    Antoniotti, G.4    Benchetrit, D.5    Cart-Lamy, P.6
  • 50
    • 0036559862 scopus 로고    scopus 로고
    • The IVD directive: Planning for compliance
    • Donawa ME. The IVD directive: planning for compliance. Med Device Technol 2002;13:22-4.
    • (2002) Med. Device Technol. , vol.13 , pp. 22-24
    • Donawa, M.E.1
  • 51
    • 0036878331 scopus 로고    scopus 로고
    • Performance evaluation and the IVD Directive
    • Spencer S. Performance evaluation and the IVD Directive. Med Device Technol 2002;13:41-3.
    • (2002) Med. Device Technol. , vol.13 , pp. 41-43
    • Spencer, S.1
  • 52
    • 0032145170 scopus 로고    scopus 로고
    • Interassay calibration as a major contribution to the comparability of results in clinical enzymology
    • Ferard G, Edwards J, Kanno T, Lessinger J-M, Moss DW, Schiele F, et al. Interassay calibration as a major contribution to the comparability of results in clinical enzymology. Clin Biochem 1998;31:489-94.
    • (1998) Clin. Biochem. , vol.31 , pp. 489-494
    • Ferard, G.1    Edwards, J.2    Kanno, T.3    Lessinger, J.-M.4    Moss, D.W.5    Schiele, F.6
  • 53
    • 0032458199 scopus 로고    scopus 로고
    • Preparation of enzyme calibration materials
    • Ferard G, Lessinger JM. Preparation of enzyme calibration materials. Clin Chim Acta 1998;278:151-62.
    • (1998) Clin. Chim. Acta , vol.278 , pp. 151-162
    • Ferard, G.1    Lessinger, J.M.2
  • 55
    • 0003973956 scopus 로고    scopus 로고
    • The certification of a matrix reference material for immunochemical measurement of 14 human serum proteins
    • CRM 470; Brussels: Community Bureau of Reference, Commission of European Communities. BCR information, Reference Materials; 1993 report EUR 15234 EN (ISSN 10 185593)
    • Baudner S, Bienvenu J, Blirup-Jensen S, Carlström A, Johnson AM, Milford Ward, et al. The certification of a matrix reference material for immunochemical measurement of 14 human serum proteins. CRM 470; Brussels: Community Bureau of Reference, Commission of European Communities. BCR information, Reference Materials; 1993 report EUR 15234 EN (ISSN 10 185593):1-172.
    • Baudner, S.1    Bienvenu, J.2    Blirup-Jensen, S.3    Carlström, A.4    Johnson, A.M.5    Milford, W.6
  • 57
    • 0035213207 scopus 로고    scopus 로고
    • Effect of Certified Reference Material 470 (CRM 470) on national quality assurance programs for serum proteins in Europe
    • Johnson AM, Whicher JT. Effect of Certified Reference Material 470 (CRM 470) on national quality assurance programs for serum proteins in Europe. Clin Chem Lab Med 2001;39:1123-8.
    • (2001) Clin. Chem. Lab. Med. , vol.39 , pp. 1123-1128
    • Johnson, A.M.1    Whicher, J.T.2
  • 58
    • 0031018045 scopus 로고    scopus 로고
    • Improvements from the reference material CRM 470 in the standardization of the determination of serum proteins
    • Bienvenu J, Doche C, Later R, Manceaux JC, Pontet F, Pressac M, et al. Improvements from the reference material CRM 470 in the standardization of the determination of serum proteins. Ann Biol Clin 1997;55:37-40.
    • (1997) Ann. Biol. Clin. , vol.55 , pp. 37-40
    • Bienvenu, J.1    Doche, C.2    Later, R.3    Manceaux, J.C.4    Pontet, F.5    Pressac, M.6
  • 59
    • 0035209728 scopus 로고    scopus 로고
    • Protein standardization III: Method optimization basic principles for quantitative determination of human serum proteins on automated instruments based on turbidimetry or nephelometry
    • Blirup-Jensen S. Protein standardization III: method optimization basic principles for quantitative determination of human serum proteins on automated instruments based on turbidimetry or nephelometry. Clin Chem Lab Med 2001;39:1098-109.
    • (2001) Clin. Chem. Lab. Med. , vol.39 , pp. 1098-1109
    • Blirup-Jensen, S.1
  • 60
    • 0035210332 scopus 로고    scopus 로고
    • Commutability of serum protein values: Persisting bias among manufacturers using values assigned from the Certified Reference Material 470 (CRM 470) in the United States
    • Ledue TB, Johnson AM. Commutability of serum protein values: persisting bias among manufacturers using values assigned from the Certified Reference Material 470 (CRM 470) in the United States. Clin Chem Lab Med 2001;39:1129-33.
    • (2001) Clin. Chem. Lab. Med. , vol.39 , pp. 1129-1133
    • Ledue, T.B.1    Johnson, A.M.2
  • 61
    • 0042766810 scopus 로고    scopus 로고
    • Biochemical surrogate markers of liver fibrosis and activity in a randomized trial of Peginterferon Alfa-2b and Ribavirin
    • Poynard T, McHutchison J, Manns M, Myers RP, Albrecht J. Biochemical surrogate markers of liver fibrosis and activity in a randomized trial of Peginterferon Alfa-2b and Ribavirin. Hepatology 2003;38:481-92.
    • (2003) Hepatology , vol.38 , pp. 481-492
    • Poynard, T.1    McHutchison, J.2    Manns, M.3    Myers, R.P.4    Albrecht, J.5
  • 62
    • 17344363641 scopus 로고    scopus 로고
    • Factors associated with serum alanine transaminase activity in healthy subjects: Consequences for the definition of normal values, for selection of blood donors, and for patients with chronic hepatitis C. MULTIVIRC group
    • Piton A, Poynard T, Imbert-Bismut F, Khalil L, Delattre J, Pelissier E, et al. Factors associated with serum alanine transaminase activity in healthy subjects: consequences for the definition of normal values, for selection of blood donors, and for patients with chronic hepatitis C. MULTIVIRC group. Hepatology 1998;27:1213-9.
    • (1998) Hepatology , vol.27 , pp. 1213-1219
    • Piton, A.1    Poynard, T.2    Imbert-Bismut, F.3    Khalil, L.4    Delattre, J.5    Pelissier, E.6
  • 63
    • 84942967862 scopus 로고
    • Reference limits of apolipoprotein A1 and apolipoprotein B using an IFCC standardized immunonephelometric method
    • Steinmetz J, Tarallo P, Fournier B, Caces E, Siest G. Reference limits of apolipoprotein A1 and apolipoprotein B using an IFCC standardized immunonephelometric method. Eur J Clin Chem Clin Biochem 1995;33:337-42.
    • (1995) Eur. J. Clin. Chem. Clin. Biochem. , vol.33 , pp. 337-342
    • Steinmetz, J.1    Tarallo, P.2    Fournier, B.3    Caces, E.4    Siest, G.5
  • 64
    • 0033815723 scopus 로고    scopus 로고
    • Population frequency distributions of HDL, HDL2 and HDL3 cholesterol apolipoproteins A1 and B in healthy men and women in associations with age, gender, hormonal status, and sex hormone use: The Stanford Five City Project
    • Gardner CD, Tribble DL, Young DR, Ahn D, Fortmann SP. Population frequency distributions of HDL, HDL2 and HDL3 cholesterol apolipoproteins A1 and B in healthy men and women in associations with age, gender, hormonal status, and sex hormone use: the Stanford Five City Project. Prev Med 2000;31:335-45.
    • (2000) Prev. Med. , vol.31 , pp. 335-345
    • Gardner, C.D.1    Tribble, D.L.2    Young, D.R.3    Ahn, D.4    Fortmann, S.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.