Volumn 51, Issue 1 I, 2004, Pages 21-26

Performance evaluation of MMP-II: A second-generation small animal PET

Author keywords

LSO; PET; Small animal imaging

Indexed keywords

DATA ACQUISITION; IMAGE ANALYSIS; MEDICAL IMAGING; NONDESTRUCTIVE EXAMINATION; PHOTOMULTIPLIERS; PHYSIOLOGY; SENSITIVITY ANALYSIS; SIGNAL PROCESSING;

EID: 2342625310     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2003.823058     Document Type: Article
Times cited : (17)

References (12)
  • 1
    • 0028998430 scopus 로고
    • The design and physical characteristics of a small-animal PET
    • P. M. Bloomfield et al., "The design and physical characteristics of a small-animal PET," Phys. Med. Biol., vol. 40, pp. 1105-1126, 1995.
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1105-1126
    • Bloomfield, P.M.1
  • 2
    • 0032978691 scopus 로고
    • Performance evaluation of MicroPET: A high resolution lutetium oxyorthosilicate PET scanner for animal imaging
    • A. F. Chatziioannou et al., "Performance evaluation of MicroPET: A high resolution lutetium oxyorthosilicate PET scanner for animal imaging," J. Nucl. Med., vol. 40, pp. 1164-1175, 1994.
    • (1994) J. Nucl. Med. , vol.40 , pp. 1164-1175
    • Chatziioannou, A.F.1
  • 3
    • 34648840245 scopus 로고    scopus 로고
    • MicroPET: A high resolution PET scanner for imaging small animals
    • S. R. Cherry et al., "MicroPET: A high resolution PET scanner for imaging small animals," IEEE Trans. Nucl. Sci., vol. 44, pp. 1161-1166, 1997.
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 1161-1166
    • Cherry, S.R.1
  • 4
    • 0032216607 scopus 로고    scopus 로고
    • Performance characteristics of a compact, position sensitive LSO module
    • J. J. Vaquera et al., "Performance characteristics of a compact, position sensitive LSO module," IEEE Trans. Med. Imaging, vol. 17, pp. 967-978, 1998.
    • (1998) IEEE Trans. Med. Imaging , vol.17 , pp. 967-978
    • Vaquera, J.J.1
  • 5
    • 0035284484 scopus 로고    scopus 로고
    • High resolution PET, SPECT and projection imaging in small animals
    • M. V. Green et al., "High resolution PET, SPECT and projection imaging in small animals," Comput. Med. Imaging Graph, vol. 25, pp. 79-96, 2001.
    • (2001) Comput. Med. Imaging Graph , vol.25 , pp. 79-96
    • Green, M.V.1
  • 6
    • 0033343644 scopus 로고    scopus 로고
    • Development of a small animal PET imaging device with resolution approaching 1 mm
    • J. A. Correia, C. A. Burnham, D. Kaufman, and A. J. Fischman, "Development of a small animal PET imaging device with resolution approaching 1 mm," IEEE Trans. Nucl. Sci., vol. 46, pp. 631-635, 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 631-635
    • Correia, J.A.1    Burnham, C.A.2    Kaufman, D.3    Fischman, A.J.4
  • 7
    • 0002804581 scopus 로고    scopus 로고
    • Design of a micro crystal element (MICE) detector unit
    • R. S. Miyaoka, S. G. Kohlmyer, and T. K. Lewellen, "Design of a micro crystal element (MICE) detector unit," J. Nucl. Med., vol. 41, p. 19P, 2000.
    • (2000) J. Nucl. Med. , vol.41
    • Miyaoka, R.S.1    Kohlmyer, S.G.2    Lewellen, T.K.3
  • 8
    • 0033312929 scopus 로고    scopus 로고
    • A Monte-Carlo simulation of a small animal PET with 1 mm resolution
    • A. Bevilaqua et al., "A Monte-Carlo simulation of a small animal PET with 1 mm resolution," IEEE Trans. Nucl. Sci. vol. 46, pp. 697-701, 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 697-701
    • Bevilaqua, A.1
  • 9
    • 0031169543 scopus 로고    scopus 로고
    • Performance study of a 3D small animal PET scanner based on BaF2 crystals and a photosensitive wire chamber
    • P. Bruyndoncks et al., "Performance study of a 3D small animal PET scanner based on BaF2 crystals and a photosensitive wire chamber," Nucl. Inst. Methods, vol. A392, pp. 407-413, 1997.
    • (1997) Nucl. Inst. Methods , vol.A392 , pp. 407-413
    • Bruyndoncks, P.1
  • 10
    • 0032596360 scopus 로고    scopus 로고
    • A 3D HIDAC-PET camera with sum-millimeter resolution for imaging small animals
    • A. P. Jeavons et al., "A 3D HIDAC-PET camera with sum-millimeter resolution for imaging small animals," IEEE Trans. Nucl. Sci., vol. 46, pp. 1067-1072, 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 1067-1072
    • Jeavons, A.P.1
  • 12
    • 2342644396 scopus 로고    scopus 로고
    • Design studies for volumetric high resolution small animal PET
    • Lyon, France, Oct.
    • _, "Design studies for volumetric high resolution small animal PET," in Proc. IEEE Medical Imaging Conf. Conf. Rec., Lyon, France, Oct. 2000, pp. 2639-2643.
    • (2000) Proc. IEEE Medical Imaging Conf. Conf. Rec. , pp. 2639-2643