-
1
-
-
0036142746
-
Prosthetic disc replacement: The future?
-
Bao QB, Yuan HA. Prosthetic disc replacement: the future? Clin Orthop 2002; 394: 139-145
-
(2002)
Clin Orthop
, vol.394
, pp. 139-145
-
-
Bao, Q.B.1
Yuan, H.A.2
-
2
-
-
0033146888
-
Adjacent-segment degeneration after lumbar fusion: A review of clinical, biomechanical, and radiologic studies
-
Eck JC, Humphreys SC, Hodges SD. Adjacent-segment degeneration after lumbar fusion: a review of clinical, biomechanical, and radiologic studies. Am J Orthop 1999; 28: 336-340
-
(1999)
Am J Orthop
, vol.28
, pp. 336-340
-
-
Eck, J.C.1
Humphreys, S.C.2
Hodges, S.D.3
-
3
-
-
0030473152
-
Adjacent-segment degeneration after lumbar fusion with instrumentation: A retrospective study
-
Rahm MD, Hall MD. Adjacent-segment degeneration after lumbar fusion with instrumentation: a retrospective study. J Spinal Disord 1996; 9: 392-400
-
(1996)
J Spinal Disord
, vol.9
, pp. 392-400
-
-
Rahm, M.D.1
Hall, M.D.2
-
4
-
-
0028954044
-
The effect of pedicle screw/plate fixation on lumbar/lumbosacral autogenous bone graft fusions in patients with degenerative disc disease
-
Wood GW, Boyd RJ, Carothers TA, Mansfield FL, Rechtine CR, Rozen MJ, Sutterlin CE. The effect of pedicle screw/plate fixation on lumbar/lumbosacral autogenous bone graft fusions in patients with degenerative disc disease. Spine 1995; 20: 819-830
-
(1995)
Spine
, vol.20
, pp. 819-830
-
-
Wood, G.W.1
Boyd, R.J.2
Carothers, T.A.3
Mansfield, F.L.4
Rechtine, C.R.5
Rozen, M.J.6
Sutterlin, C.E.7
-
5
-
-
0026772519
-
Clinical efficacy of spinal instrumentation in lumbar degenerative disc disease
-
Zuchermann J, Hsu K, Picetti G, White A, Wynne C, Taylor L. Clinical efficacy of spinal instrumentation in lumbar degenerative disc disease. Spine 1992; 17: 834-837
-
(1992)
Spine
, vol.17
, pp. 834-837
-
-
Zuchermann, J.1
Hsu, K.2
Picetti, G.3
White, A.4
Wynne, C.5
Taylor, L.6
-
6
-
-
0005768237
-
Clinical trial to investigate stabilization of the spine
-
Aspden RM, Porter RW (eds). World Scientific Publishing, Singapore
-
Fairbank J, Frost H, Wilson-MacDonald J. Clinical trial to investigate stabilization of the spine. In: Aspden RM, Porter RW (eds). Lumbar spine disorders-current concepts. Vol. 2. World Scientific Publishing, Singapore 1996; 143-160
-
(1996)
Lumbar Spine Disorders-current Concepts
, vol.2
, pp. 143-160
-
-
Fairbank, J.1
Frost, H.2
Wilson-MacDonald, J.3
-
7
-
-
0034465525
-
Spinal fusion for lumbar instability: Does it have a scientific basis?
-
Muggleton JM, Kondracki M, Allen R. Spinal fusion for lumbar instability: does it have a scientific basis? J Spinal Disord 2000; 13: 200-204
-
(2000)
J Spinal Disord
, vol.13
, pp. 200-204
-
-
Muggleton, J.M.1
Kondracki, M.2
Allen, R.3
-
8
-
-
0031889329
-
Long-term outcome of patients suffering from clinical instability after microsurgical treatment of lumbar disc herniation
-
Wien
-
Kotilainen E. Long-term outcome of patients suffering from clinical instability after microsurgical treatment of lumbar disc herniation. Acta Neurochir (Wien) 1998; 140: 120-125
-
(1998)
Acta Neurochir
, vol.140
, pp. 120-125
-
-
Kotilainen, E.1
-
9
-
-
0033994184
-
Clinical and radiographic evaluation of disc excision for lumbar disc herniation with and without posterolateral fusion
-
Takeshima T, Kambara K, Miyata S, Ueda Y, Tamai S. Clinical and radiographic evaluation of disc excision for lumbar disc herniation with and without posterolateral fusion. Spine 2000; 25: 450-456
-
(2000)
Spine
, vol.25
, pp. 450-456
-
-
Takeshima, T.1
Kambara, K.2
Miyata, S.3
Ueda, Y.4
Tamai, S.5
-
10
-
-
0031418708
-
Preliminary design and experimental studies of a novel soft implant for correcting sagittal plane instability in the lumbar spine
-
Minns RJ, Walsh WK. Preliminary design and experimental studies of a novel soft implant for correcting sagittal plane instability in the lumbar spine. Spine 1997; 22: 1819-1825; discussion 1826-1827
-
(1997)
Spine
, vol.22
, pp. 1819-1825
-
-
Minns, R.J.1
Walsh, W.K.2
-
11
-
-
0036033686
-
Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments: The Wallis system
-
Senegas J. Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments: the Wallis system. Eur Spine J 2002; 11 (Suppl 2): 164-169
-
(2002)
Eur Spine J
, vol.11
, Issue.2 SUPPL.
, pp. 164-169
-
-
Senegas, J.1
-
12
-
-
0034960644
-
Graf ligament stabilization: Mid- to long-term follow-up
-
Rigby MC, Selmon GP, Foy MA, Fogg AJ. Graf ligament stabilization: mid- to long-term follow-up. Eur Spine J 2001; 10: 234-236
-
(2001)
Eur Spine J
, vol.10
, pp. 234-236
-
-
Rigby, M.C.1
Selmon, G.P.2
Foy, M.A.3
Fogg, A.J.4
-
13
-
-
0036034166
-
A spiral implant as nucleus prosthesis in the lumbar spine
-
Korge A, Nydegger T, Polard JL, Mayer HM, Husson JL. A spiral implant as nucleus prosthesis in the lumbar spine. Eur Spine J 2002; 11 (Suppl 2): 149-153
-
(2002)
Eur Spine J
, vol.11
, Issue.2 SUPPL.
, pp. 149-153
-
-
Korge, A.1
Nydegger, T.2
Polard, J.L.3
Mayer, H.M.4
Husson, J.L.5
-
14
-
-
0036033927
-
The PDN prosthetic disc-nucleus device
-
Ray CD. The PDN prosthetic disc-nucleus device. Eur Spine J 2002; 11 (Suppl 2): 137-142
-
(2002)
Eur Spine J
, vol.11
, Issue.2 SUPPL.
, pp. 137-142
-
-
Ray, C.D.1
-
15
-
-
0036033685
-
History, design and biomechanics of the LINK SB Charite artificial disc
-
Link HD. History, design and biomechanics of the LINK SB Charite artificial disc. Eur Spine J 2002; 11 (Suppl 2): 98-105
-
(2002)
Eur Spine J
, vol.11
, Issue.2 SUPPL.
, pp. 98-105
-
-
Link, H.D.1
-
16
-
-
0033032537
-
Dynamic neutralization of the lumbar spine confirmed on a new lumbar spine simulator in vitro
-
Freudiger S, Dubois G, Lorrain M. Dynamic neutralization of the lumbar spine confirmed on a new lumbar spine simulator in vitro. Arch Orthop Trauma Surg 1999; 119: 127-132
-
(1999)
Arch Orthop Trauma Surg
, vol.119
, pp. 127-132
-
-
Freudiger, S.1
Dubois, G.2
Lorrain, M.3
-
19
-
-
0002661601
-
Dynamic neutralization: A new concept for restabilization of the spine
-
Szpalski M, Gunzburg R, Pope MH (eds). Lippincott Williams & Wilkins, Philadelphia
-
Dubois G, deGermay B, Schaerer N, Fennema P. Dynamic neutralization: a new concept for restabilization of the spine. In: Szpalski M, Gunzburg R, Pope MH (eds). Lumbar Segmental Instability. Lippincott Williams & Wilkins, Philadelphia 1999; 233-240
-
(1999)
Lumbar Segmental Instability
, pp. 233-240
-
-
Dubois, G.1
DeGermay, B.2
Schaerer, N.3
Fennema, P.4
-
20
-
-
0021235595
-
Magnetic resonance imaging of intervertebral disk disease. Clinical and pulse sequence considerations
-
Modic MT, Pavlicek W, Weinstein MA, Boumphrey F, Ngo F, Hardy R, Duchesneau PM. Magnetic resonance imaging of intervertebral disk disease. Clinical and pulse sequence considerations. Radiology 1984; 152: 103-111
-
(1984)
Radiology
, vol.152
, pp. 103-111
-
-
Modic, M.T.1
Pavlicek, W.2
Weinstein, M.A.3
Boumphrey, F.4
Ngo, F.5
Hardy, R.6
Duchesneau, P.M.7
-
21
-
-
0020565719
-
Terminology and measurement of spondylolisthesis
-
Wiltse IL, Winter RB. Terminology and measurement of spondylolisthesis. J Bone Joint Surg [Am] 1983; 65: 768-772
-
(1983)
J Bone Joint Surg [Am]
, vol.65
, pp. 768-772
-
-
Wiltse, I.L.1
Winter, R.B.2
-
22
-
-
2342495081
-
Stenosis of the bony lumbar vertebral canal
-
Wackenheim A (ed). Berlin; Springer
-
Verbiest H. Stenosis of the bony lumbar vertebral canal. In: Wackenheim A (ed). The Narrow Lumbar Canal. Berlin; Springer 1977; 115-145
-
(1977)
The Narrow Lumbar Canal
, pp. 115-145
-
-
Verbiest, H.1
-
23
-
-
0037111881
-
General principles of diagnostic testing as related to painful lumbar spine disorders: A critical appraisal of current diagnostic techniques
-
Saal JS. General principles of diagnostic testing as related to painful lumbar spine disorders: a critical appraisal of current diagnostic techniques. Spine 2002; 27: 2538-2545; discussion 2546
-
(2002)
Spine
, vol.27
, pp. 2538-2545
-
-
Saal, J.S.1
-
24
-
-
0036704832
-
Health-related quality of life in patients with chronic pain
-
Gerbershagen HU, Lindena G, Korb J, Kramer S. Health-related quality of life in patients with chronic pain. Schmerz 2002; 16: 271-284
-
(2002)
Schmerz
, vol.16
, pp. 271-284
-
-
Gerbershagen, H.U.1
Lindena, G.2
Korb, J.3
Kramer, S.4
-
26
-
-
0035499619
-
Visual analog scales for interpretation of back and leg pain intensity in patients operated for degenerative lumbar spine disorders
-
Zanoli G, Stromqvist B, Jonsson B. Visual analog scales for interpretation of back and leg pain intensity in patients operated for degenerative lumbar spine disorders. Spine 2001; 26: 2375-2380
-
(2001)
Spine
, vol.26
, pp. 2375-2380
-
-
Zanoli, G.1
Stromqvist, B.2
Jonsson, B.3
-
27
-
-
0028036716
-
A historical cohort study of pedicle screw fixation in thoracic, lumbar and sacral spinal fusions
-
Yuan HA, Garfin SR, Curtis AD, Mardjetko SM. A historical cohort study of pedicle screw fixation in thoracic, lumbar and sacral spinal fusions. Spine 1994; 19 (Suppl): 2279-2296
-
(1994)
Spine
, vol.19
, Issue.SUPPL.
, pp. 2279-2296
-
-
Yuan, H.A.1
Garfin, S.R.2
Curtis, A.D.3
Mardjetko, S.M.4
-
28
-
-
0035868784
-
Disc Height and Signal Intensity of the Nucleus Pulposus on Magnetic Resonance Imaging as Indicators of Lumbar Disc Degeneration
-
Luoma K, Vehmas T, Riihimäki H, Raininko R. Disc Height and Signal Intensity of the Nucleus Pulposus on Magnetic Resonance Imaging as Indicators of Lumbar Disc Degeneration. Spine 2001; 26: 680-686
-
(2001)
Spine
, vol.26
, pp. 680-686
-
-
Luoma, K.1
Vehmas, T.2
Riihimäki, H.3
Raininko, R.4
-
29
-
-
0038350852
-
Comparison of dynamic posteroanterior spinal stiffness to plain film radiographic images of lumbar disk height
-
Colloca CJ, Keller TS, Peterson TK, Seltzer DE. Comparison of dynamic posteroanterior spinal stiffness to plain film radiographic images of lumbar disk height. J Manipulative Physiol Ther 2003; 26: 233-241
-
(2003)
J Manipulative Physiol Ther
, vol.26
, pp. 233-241
-
-
Colloca, C.J.1
Keller, T.S.2
Peterson, T.K.3
Seltzer, D.E.4
-
30
-
-
0028305285
-
Disc degeneration affects the multidirectional flexibility of the lumbar spine
-
Mimura M, Panjabi MM, Oxland TR, Crisco JJ, Yamamoto I, Vasavada A. Disc degeneration affects the multidirectional flexibility of the lumbar spine. Spine 1994; 19: 1371-1380
-
(1994)
Spine
, vol.19
, pp. 1371-1380
-
-
Mimura, M.1
Panjabi, M.M.2
Oxland, T.R.3
Crisco, J.J.4
Yamamoto, I.5
Vasavada, A.6
-
31
-
-
0031792445
-
Vertebral endplate (Modic) changes on lumbar spine MRI: Correlation with pain reproduction at lumbar discography
-
Braithwaite I, White J, Saifuddin A, Renton P, Taylor BA. Vertebral endplate (Modic) changes on lumbar spine MRI: correlation with pain reproduction at lumbar discography. Eur Spine J 1998; 7: 363-368
-
(1998)
Eur Spine J
, vol.7
, pp. 363-368
-
-
Braithwaite, I.1
White, J.2
Saifuddin, A.3
Renton, P.4
Taylor, B.A.5
-
32
-
-
0031776995
-
Differentialdiagnose der erosiven Osteochondrose und bakteriellen Spondylitis in der Magnetresonanztomographie (MRT)
-
Stäbler A, Baur A, Krüger A, Weiss M, Helmberger T, Reiser M. Differentialdiagnose der erosiven Osteochondrose und bakteriellen Spondylitis in der Magnetresonanztomographie (MRT). Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 1998; 168: 421-428
-
(1998)
Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr
, vol.168
, pp. 421-428
-
-
Stäbler, A.1
Baur, A.2
Krüger, A.3
Weiss, M.4
Helmberger, T.5
Reiser, M.6
-
33
-
-
0025195693
-
Lumbar spinal fusion. Assessment of functional stability with magnetic resonance imaging
-
Lang P, Chafetz N, Genant HK, Morris JM. Lumbar spinal fusion. Assessment of functional stability with magnetic resonance imaging. Spine 1990; 15: 581-588
-
(1990)
Spine
, vol.15
, pp. 581-588
-
-
Lang, P.1
Chafetz, N.2
Genant, H.K.3
Morris, J.M.4
-
34
-
-
0035478558
-
The effect of nucleotomy on lumbar spine mechanics in compression and shear loading
-
Frei H, Oxland TR, Rathonyi GC, Nolte LP. The effect of nucleotomy on lumbar spine mechanics in compression and shear loading. Spine 2001; 26: 2080-2089
-
(2001)
Spine
, vol.26
, pp. 2080-2089
-
-
Frei, H.1
Oxland, T.R.2
Rathonyi, G.C.3
Nolte, L.P.4
-
35
-
-
0027739973
-
Clinical instability of the lumbar spine after microdiscectomy
-
Wien
-
Kotilainen E, Valtonen S. Clinical instability of the lumbar spine after microdiscectomy. Acta Neurochir (Wien) 1993; 125: 120-126
-
(1993)
Acta Neurochir
, vol.125
, pp. 120-126
-
-
Kotilainen, E.1
Valtonen, S.2
-
36
-
-
0032526329
-
Biomechanical evaluation of translaminar facet joint fixation. A comparative study of poly-L-lactide pins, screws, and pedicle fixation
-
Deguchi M, Cheng BC, Sato K, Matsuyama Y, Zdeblick TA. Biomechanical evaluation of translaminar facet joint fixation. A comparative study of poly-L-lactide pins, screws, and pedicle fixation. Spine 1998; 23: 1307-1312
-
(1998)
Spine
, vol.23
, pp. 1307-1312
-
-
Deguchi, M.1
Cheng, B.C.2
Sato, K.3
Matsuyama, Y.4
Zdeblick, T.A.5
-
37
-
-
0036034888
-
Indications for full prosthetic disc arthroplasty: A correlation of clinical outcome against a variety of indications
-
Bertagnoli R, Kumar S. Indications for full prosthetic disc arthroplasty: a correlation of clinical outcome against a variety of indications. Eur Spine J 2002; 11 (Suppl 2): 131-136
-
(2002)
Eur Spine J
, vol.11
, Issue.2 SUPPL.
, pp. 131-136
-
-
Bertagnoli, R.1
Kumar, S.2
-
38
-
-
0036742367
-
Disc replacement with the SB Charite endoprosthesis - Experience, preliminary results and comments after 35 prospectively performed operations
-
Hopf C, Heeckt H, Beske C. Disc replacement with the SB Charite endoprosthesis - experience, preliminary results and comments after 35 prospectively performed operations. Z Orthop Ihre Grenzgeb 2002; 140: 485-491
-
(2002)
Z Orthop Ihre Grenzgeb
, vol.140
, pp. 485-491
-
-
Hopf, C.1
Heeckt, H.2
Beske, C.3
-
39
-
-
0031879695
-
Surgical results after soft system stabilization of the lumbar spine in degenerative disc disease - Long-term results
-
Wien
-
Brechbuhler D, Markwalder TM, Braun M. Surgical results after soft system stabilization of the lumbar spine in degenerative disc disease - long-term results. Acta Neurochir (Wien) 1998; 140: 521-525
-
(1998)
Acta Neurochir
, vol.140
, pp. 521-525
-
-
Brechbuhler, D.1
Markwalder, T.M.2
Braun, M.3
-
40
-
-
0032523227
-
The Graf ligamentoplasty procedure. Comparison with posterolateral fusion in the management of low back pain
-
Hadlow SV, Fagan AB, Hillier TM, Fraser RD. The Graf ligamentoplasty procedure. Comparison with posterolateral fusion in the management of low back pain. Spine 1998; 23: 1172-1179
-
(1998)
Spine
, vol.23
, pp. 1172-1179
-
-
Hadlow, S.V.1
Fagan, A.B.2
Hillier, T.M.3
Fraser, R.D.4
-
41
-
-
0029053886
-
Soft system stabilization of the lumbar spine as an alternative surgical modality to lumbar arthrodesis in the facet syndrome. Preliminary results
-
Wien
-
Markwalder TM, Dubach R, Braun M. Soft system stabilization of the lumbar spine as an alternative surgical modality to lumbar arthrodesis in the facet syndrome. Preliminary results. Acta Neurochir (Wien) 1995; 134: 1-4
-
(1995)
Acta Neurochir
, vol.134
, pp. 1-4
-
-
Markwalder, T.M.1
Dubach, R.2
Braun, M.3
-
43
-
-
0025238734
-
Discs degenerate before facets
-
Butler D, Trafimow JH, Andersson GB, McNeill TW, Huckman MS. Discs degenerate before facets. Spine 1990; 15: 111-113
-
(1990)
Spine
, vol.15
, pp. 111-113
-
-
Butler, D.1
Trafimow, J.H.2
Andersson, G.B.3
McNeill, T.W.4
Huckman, M.S.5
-
44
-
-
0032744655
-
The relationship between facet joint osteoarthritis and disc degeneration of the lumbar spine: An MRI study
-
Fujiwara A, Tamai K, Yamato M, An HS, Yoshida H, Saotome K, Kurihashi A. The relationship between facet joint osteoarthritis and disc degeneration of the lumbar spine: an MRI study. Eur Spine J 1999; 8: 396-401
-
(1999)
Eur Spine J
, vol.8
, pp. 396-401
-
-
Fujiwara, A.1
Tamai, K.2
Yamato, M.3
An, H.S.4
Yoshida, H.5
Saotome, K.6
Kurihashi, A.7
-
45
-
-
0025715628
-
Stabilization surgery of the spine
-
28120
-
Aebi M. Stabilization surgery of the spine. Schweiz Med Wochenschr 1990; 28120: 605-616
-
(1990)
Schweiz Med Wochenschr
, pp. 605-616
-
-
Aebi, M.1
-
46
-
-
0036035142
-
The dynamic neutralization system for the spine: A multi-center study of a novel non-fusion system
-
Stoll TM, Dubois G, Schwarzenbach O. The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 2002; 11 (Suppl 2): 170-178
-
(2002)
Eur Spine J
, vol.11
, Issue.2 SUPPL.
, pp. 170-178
-
-
Stoll, T.M.1
Dubois, G.2
Schwarzenbach, O.3
|