메뉴 건너뛰기




Volumn 99, Issue 1, 2004, Pages 98-105

Coated wire lead(II) selective potentiometric sensor based on 4-tert-butylcalix[6]arene

Author keywords

5,11,17,23,29,35 Hexa tert butyl 37,38,39,40,41,42 hexahydroxycalix 6 arene; Coated wire ion selective electrode; Lead; Potentiometry

Indexed keywords

COATED WIRE ELECTRODES; DISTILLATION; EFFLUENTS; ELECTROPLATING; ION SELECTIVE ELECTRODES; LEAD; PH EFFECTS; POLYVINYL CHLORIDES; TITRATION;

EID: 2342576879     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2003.11.001     Document Type: Article
Times cited : (77)

References (47)
  • 1
    • 0001647570 scopus 로고
    • Lead (II) ion-selective electrodes based on crown ethers
    • Sheen S.-R., Shih J.-S. Lead (II) ion-selective electrodes based on crown ethers. Analyst. 117:1992;1691-1695.
    • (1992) Analyst , vol.117 , pp. 1691-1695
    • Sheen, S.-R.1    Shih, J.-S.2
  • 3
    • 0001168010 scopus 로고
    • Lead-selective membrane electrode using methylene bis(diisobutyl dithio carbamate) neutral carrier
    • Kamata S., Onoyama K. Lead-selective membrane electrode using methylene bis(diisobutyl dithio carbamate) neutral carrier. Anal. Chem. 63:1991;1295-1298.
    • (1991) Anal. Chem. , vol.63 , pp. 1295-1298
    • Kamata, S.1    Onoyama, K.2
  • 4
    • 0021439360 scopus 로고
    • Lead-selective neutral carrier based liquid membrane electrode
    • Lindner E., Tóth K., Pungor E. Lead-selective neutral carrier based liquid membrane electrode. Anal. Chem. 56:1984;1127-1131.
    • (1984) Anal. Chem. , vol.56 , pp. 1127-1131
    • Lindner, E.1    Tóth, K.2    Pungor, E.3
  • 5
    • 37049083988 scopus 로고
    • Determination of lead using a poly(vinyl chloride)-based crown ether membrane
    • Srivastava S.K., Gupta V.K., Jain S. Determination of lead using a poly(vinyl chloride)-based crown ether membrane. Analyst. 120:1995;495-498.
    • (1995) Analyst , vol.120 , pp. 495-498
    • Srivastava, S.K.1    Gupta, V.K.2    Jain, S.3
  • 6
    • 0000321833 scopus 로고    scopus 로고
    • Lead-selective membrane electrode based on dibenzopyrydino-18-crown-6
    • Tavakkoli N., Shamsipur M. Lead-selective membrane electrode based on dibenzopyrydino-18-crown-6. Anal. Lett. 29:1996;2269-2279.
    • (1996) Anal. Lett. , vol.29 , pp. 2269-2279
    • Tavakkoli, N.1    Shamsipur, M.2
  • 7
    • 84987532013 scopus 로고
    • Macrocyclic oxamides as ionophores for lead-selective membrane electrodes
    • Malinowska E., Jurczak J., Stankiewicz T. Macrocyclic oxamides as ionophores for lead-selective membrane electrodes. Electroanalysis. 5:1993;489-492.
    • (1993) Electroanalysis , vol.5 , pp. 489-492
    • Malinowska, E.1    Jurczak, J.2    Stankiewicz, T.3
  • 8
    • 0032502279 scopus 로고    scopus 로고
    • Lead ion-selective membrane electrodes based on some recently synthesized 9, 10-anthraquinone derivatives
    • Tavakkoli N., Khojasteh Z., Sharghi H., Shamsipur M. Lead ion-selective membrane electrodes based on some recently synthesized 9, 10-anthraquinone derivatives. Anal. Chim. Acta. 360:1998;203-208.
    • (1998) Anal. Chim. Acta. , vol.360 , pp. 203-208
    • Tavakkoli, N.1    Khojasteh, Z.2    Sharghi, H.3    Shamsipur, M.4
  • 9
    • 0032890236 scopus 로고    scopus 로고
    • Lead-selective electrode by using benzyl disulphide as ionophore
    • Abbaspour A., Tavakol F. Lead-selective electrode by using benzyl disulphide as ionophore. Anal. Chim. Acta. 378:1999;145-149.
    • (1999) Anal. Chim. Acta. , vol.378 , pp. 145-149
    • Abbaspour, A.1    Tavakol, F.2
  • 10
    • 0032720509 scopus 로고    scopus 로고
    • Lead-selective membrane electrode based on dibenzyl phosphate
    • Xu D., Katsu T. Lead-selective membrane electrode based on dibenzyl phosphate. Anal. Chim. Acta. 401:1999;111-115.
    • (1999) Anal. Chim. Acta. , vol.401 , pp. 111-115
    • Xu, D.1    Katsu, T.2
  • 11
    • 0009806962 scopus 로고    scopus 로고
    • Lead(II)-selective membrane electrodes based on 4,7,13,16-tetrathenoyl-1, 10-dioxa-4,7,13,16-tetraazacyclooctadecane
    • Yang X., Kumar N., Chi H., Hibbert D.B., Alexander P.W. Lead(II)-selective membrane electrodes based on 4,7,13,16-tetrathenoyl-1,10- dioxa-4,7,13,16-tetraazacyclooctadecane. Electroanalysis. 10:1998;827-831.
    • (1998) Electroanalysis , vol.10 , pp. 827-831
    • Yang, X.1    Kumar, N.2    Chi, H.3    Hibbert, D.B.4    Alexander, P.W.5
  • 12
    • 0034212179 scopus 로고    scopus 로고
    • Lead ion-selective membrane electrode based on 1,10-dibenzyl-1,10-diaza- 18-crown-6
    • Mousavi M.F., Sahari S., Alizadeh N., Shamsipur M. Lead ion-selective membrane electrode based on 1,10-dibenzyl-1,10-diaza-18-crown-6. Anal. Chim. Acta. 414:2000;189-194.
    • (2000) Anal. Chim. Acta. , vol.414 , pp. 189-194
    • Mousavi, M.F.1    Sahari, S.2    Alizadeh, N.3    Shamsipur, M.4
  • 13
    • 0034868278 scopus 로고    scopus 로고
    • Lead-selective membrane potentiometric sensor based on an 18-membered thiacrown derivative
    • Shamsipur M., Ganjali M.R., Rouhollahi A. Lead-selective membrane potentiometric sensor based on an 18-membered thiacrown derivative. Anal. Sci. 17:2001;935-938.
    • (2001) Anal. Sci. , vol.17 , pp. 935-938
    • Shamsipur, M.1    Ganjali, M.R.2    Rouhollahi, A.3
  • 14
    • 0037021777 scopus 로고    scopus 로고
    • Lead-selective poly(vinyl chloride) membrane electrode based on piroxicam as a neutral carrier
    • Sadeghi S., Dashti G.R., Shamsipur M. Lead-selective poly(vinyl chloride) membrane electrode based on piroxicam as a neutral carrier. Sens. Actuators, B, Chem. 81:2002;223-228.
    • (2002) Sens. Actuators, B, Chem. , vol.81 , pp. 223-228
    • Sadeghi, S.1    Dashti, G.R.2    Shamsipur, M.3
  • 15
    • 0033572890 scopus 로고    scopus 로고
    • Lead-selective electrodes based on calixarenes phosphine oxide derivatives
    • Cadogan F., Kane P., McKervey M.A., Diamond D. Lead-selective electrodes based on calixarenes phosphine oxide derivatives. Anal. Chem. 71:1999;5544-5550.
    • (1999) Anal. Chem. , vol.71 , pp. 5544-5550
    • Cadogan, F.1    Kane, P.2    Mckervey, M.A.3    Diamond, D.4
  • 16
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    • Bühlmann P., Pretsch E., Bakker E. Carrier-based ion-selective electrodes and bulk optodes. 2. ionophores for potentiometric and optical sensors. Chem. Rev. 98:1998;1593-1687.
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Bühlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 17
    • 0034583224 scopus 로고    scopus 로고
    • Potentiometric selectivity coefficients of ion-selective electrodes. Part I. Inorganic cations
    • Umezawa Y., Bühlmann P., Umezawa K., Tohda K., Amemiya S. Potentiometric selectivity coefficients of ion-selective electrodes. Part I. Inorganic cations. Pure Appl. Chem. 72:2000;1851-2082.
    • (2000) Pure Appl. Chem. , vol.72 , pp. 1851-2082
    • Umezawa, Y.1    Bühlmann, P.2    Umezawa, K.3    Tohda, K.4    Amemiya, S.5
  • 19
    • 0036329673 scopus 로고    scopus 로고
    • Potentiometric selectivity coefficients of ion-selective electrodes. Part III. Organic ions
    • Umezawa Y., Bühlmann P., Umezawa K., Hamada N. Potentiometric selectivity coefficients of ion-selective electrodes. Part III. Organic ions. Pure Appl. Chem. 74:2002;995-1099.
    • (2002) Pure Appl. Chem. , vol.74 , pp. 995-1099
    • Umezawa, Y.1    Bühlmann, P.2    Umezawa, K.3    Hamada, N.4
  • 20
    • 0004146786 scopus 로고
    • The Royal Society of Chemistry, Cambridge
    • C.D. Gutsche, Calixarenes, The Royal Society of Chemistry, Cambridge, 1989.
    • (1989) Calixarenes
    • Gutsche, C.D.1
  • 22
    • 0035159249 scopus 로고    scopus 로고
    • Calixarenes: Designer ligands for chemical sensors
    • Diamond D., Nolan K. Calixarenes: designer ligands for chemical sensors. Anal. Chem. 73:2001;22A-29A.
    • (2001) Anal. Chem. , vol.73
    • Diamond, D.1    Nolan, K.2
  • 23
    • 0000828975 scopus 로고    scopus 로고
    • Calixarene derivatized with sulfur-containing functionalities as selective extractants for heavy and precious metal ions
    • Yordanov A.T., Whittlesey B.R., Roundhill D.M. Calixarene derivatized with sulfur-containing functionalities as selective extractants for heavy and precious metal ions. Inorg. Chem. 37:1998;3526-3531.
    • (1998) Inorg. Chem. , vol.37 , pp. 3526-3531
    • Yordanov, A.T.1    Whittlesey, B.R.2    Roundhill, D.M.3
  • 25
    • 0035838484 scopus 로고    scopus 로고
    • Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry
    • Honeychurch K.C., Hart J.P., Cowell D.C., Arrigan D.W.M. Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry. Sens. Actuators, B, Chem. 77:2001;642-652.
    • (2001) Sens. Actuators, B, Chem. , vol.77 , pp. 642-652
    • Honeychurch, K.C.1    Hart, J.P.2    Cowell, D.C.3    Arrigan, D.W.M.4
  • 26
    • 2342572028 scopus 로고    scopus 로고
    • Lead ion-selective electrode based on upper-rim calix[4]crown ionophore
    • Namgung M., Ihm H., Paek K., Yun Y. Lead ion-selective electrode based on upper-rim calix[4]crown ionophore. J. Korean Chem. Soc. 44:2000;115-119.
    • (2000) J. Korean Chem. Soc. , vol.44 , pp. 115-119
    • Namgung, M.1    Ihm, H.2    Paek, K.3    Yun, Y.4
  • 27
    • 0000294193 scopus 로고    scopus 로고
    • Lead vs. cadmium selectivity of ion selective electrodes based on thiophosphorylated calix[6]arene ionophores
    • Wroblewski W., Brzozka Z., Janssen R.G., Verboom W., Reinhoudt D.N. Lead vs. cadmium selectivity of ion selective electrodes based on thiophosphorylated calix[6]arene ionophores. New J. Chem. 20:1996;419-426.
    • (1996) New J. Chem. , vol.20 , pp. 419-426
    • Wroblewski, W.1    Brzozka, Z.2    Janssen, R.G.3    Verboom, W.4    Reinhoudt, D.N.5
  • 28
    • 0000000504 scopus 로고    scopus 로고
    • Determination of uranyl ions using poly (vinyl chloride) based 4-tert-butylcalix[6]arene membrane sensor
    • Gupta V.K., Mangla R., Khurana U., Kumar P. Determination of uranyl ions using poly (vinyl chloride) based 4-tert-butylcalix[6]arene membrane sensor. Electroanalysis. 11:1999;573-576.
    • (1999) Electroanalysis , vol.11 , pp. 573-576
    • Gupta, V.K.1    Mangla, R.2    Khurana, U.3    Kumar, P.4
  • 29
    • 0037809198 scopus 로고    scopus 로고
    • Comparative study of the response of membrane electrodes based on calix[6]arene and calix[8]arene derivatives to organic ammonium ions
    • Katsu T., Okaki N., Watanabe K., Takaishi K., Yokosu H. Comparative study of the response of membrane electrodes based on calix[6]arene and calix[8]arene derivatives to organic ammonium ions. Anal. Sci. 19:2003;771-774.
    • (2003) Anal. Sci. , vol.19 , pp. 771-774
    • Katsu, T.1    Okaki, N.2    Watanabe, K.3    Takaishi, K.4    Yokosu, H.5
  • 31
    • 0001486758 scopus 로고
    • Coated wire ion selective electrodes
    • James H., Carmack G., Freiser H. Coated wire ion selective electrodes. Anal. Chem. 44:1972;856-857.
    • (1972) Anal. Chem. , vol.44 , pp. 856-857
    • James, H.1    Carmack, G.2    Freiser, H.3
  • 32
    • 0002011127 scopus 로고
    • Coated-wire ion-selective electrodes
    • Cunningham L., Freiser H. Coated-wire ion-selective electrodes. Anal. Chim. Acta. 180:1986;271-279.
    • (1986) Anal. Chim. Acta , vol.180 , pp. 271-279
    • Cunningham, L.1    Freiser, H.2
  • 33
    • 37049091002 scopus 로고
    • Coated wire ion-selective electrodes
    • Freiser H. Coated wire ion-selective electrodes. J. Chem. Soc., Faraday Trans. l. 82:1986;1217-1221.
    • (1986) J. Chem. Soc., Faraday Trans. l , vol.82 , pp. 1217-1221
    • Freiser, H.1
  • 34
    • 0032164733 scopus 로고    scopus 로고
    • Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes
    • Schnierie P., Kappes T., Hauser P.C. Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes. Anal. Chem. 70:1998;3585-3589.
    • (1998) Anal. Chem. , vol.70 , pp. 3585-3589
    • Schnierie, P.1    Kappes, T.2    Hauser, P.C.3
  • 36
    • 33749015900 scopus 로고
    • Calixarenes. 4. The synthesis, characterization, and properties of the calixarenes from p-tert-butylphenol
    • Gutsche C.D., Dhawan B., No K.H., Muthukrishnan R. Calixarenes. 4. The synthesis, characterization, and properties of the calixarenes from p-tert-butylphenol. J. Am. Chem. Soc. 103:1981;3782-3792.
    • (1981) J. Am. Chem. Soc. , vol.103 , pp. 3782-3792
    • Gutsche, C.D.1    Dhawan, B.2    No, K.H.3    Muthukrishnan, R.4
  • 38
    • 4544366331 scopus 로고    scopus 로고
    • Carrier-based ion selective electrodes and bulk optodes. Part 1. General characteristics
    • Bakker E., Bühlmann P., Pretsch E. Carrier-based ion selective electrodes and bulk optodes. Part 1. General characteristics. Chem. Rev. 97:1997;3083-3132.
    • (1997) Chem. Rev. , vol.97 , pp. 3083-3132
    • Bakker, E.1    Bühlmann, P.2    Pretsch, E.3
  • 39
    • 2342558345 scopus 로고    scopus 로고
    • V.S. Bhat, A.K. Srivastava (in preparation)
    • V.S. Bhat, A.K. Srivastava (in preparation).
  • 40
    • 84987539052 scopus 로고
    • Catalysis of ion transfer by tetraphenylborates in neutral carrier based ISEs
    • Gehrig P.M., Morf W.E., Welti M., Pretsch E., Simon W. Catalysis of ion transfer by tetraphenylborates in neutral carrier based ISEs. Helv. Chim. Acta. 73:1990;203-212.
    • (1990) Helv. Chim. Acta. , vol.73 , pp. 203-212
    • Gehrig, P.M.1    Morf, W.E.2    Welti, M.3    Pretsch, E.4    Simon, W.5
  • 41
    • 0036744107 scopus 로고    scopus 로고
    • Lead(II)-selective electrode based on phenyl disulfide
    • Abbaspour A., Khajeh B. Lead(II)-selective electrode based on phenyl disulfide. Anal. Sci. 18:2002;987-991.
    • (2002) Anal. Sci. , vol.18 , pp. 987-991
    • Abbaspour, A.1    Khajeh, B.2
  • 42
    • 2342545194 scopus 로고    scopus 로고
    • Coated wire lead(II) ion-selective electrodes based on crown ethers
    • Jang M.K., Ha K.S., Seo M.L. Coated wire lead(II) ion-selective electrodes based on crown ethers. J. Korean Chem. Soc. 41:1997;337-342.
    • (1997) J. Korean Chem. Soc. , vol.41 , pp. 337-342
    • Jang, M.K.1    Ha, K.S.2    Seo, M.L.3
  • 44
    • 0019008094 scopus 로고
    • Life time of neutral carrier based ion-selective liquid-membrane electrodes
    • Oesch U., Simon W. Life time of neutral carrier based ion-selective liquid-membrane electrodes. Anal. Chem. 52:1980;692-700.
    • (1980) Anal. Chem. , vol.52 , pp. 692-700
    • Oesch, U.1    Simon, W.2
  • 45
    • 0032913492 scopus 로고    scopus 로고
    • Cadmium(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix
    • Gupta V.K., Kumar P. Cadmium(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix. Anal. Chim. Acta. 389:1999;205-212.
    • (1999) Anal. Chim. Acta , vol.389 , pp. 205-212
    • Gupta, V.K.1    Kumar, P.2
  • 46
    • 0030129986 scopus 로고    scopus 로고
    • PVC-based 2,2,2-cryptand sensor for zinc(II) ions
    • Srivastava S.K., Gupta V.K., Jain S. PVC-based 2,2,2-cryptand sensor for zinc(II) ions. Anal. Chem. 68:1996;1272-1275.
    • (1996) Anal. Chem. , vol.68 , pp. 1272-1275
    • Srivastava, S.K.1    Gupta, V.K.2    Jain, S.3
  • 47
    • 0036749313 scopus 로고    scopus 로고
    • Coated wire copper(ii) ion selective electrode based on 5,6,14,15-dibenzo-1,4-dioxa-8,12-diazacyclopentadeca-5,14-diene
    • Sil A., Ijeri V.S., Srivastava A.K. Coated wire copper(ii) ion selective electrode based on 5,6,14,15-dibenzo-1,4-dioxa-8,12-diazacyclopentadeca-5,14- diene. Electroanalysis. 14:2002;1215-1217.
    • (2002) Electroanalysis , vol.14 , pp. 1215-1217
    • Sil, A.1    Ijeri, V.S.2    Srivastava, A.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.