-
1
-
-
0022238278
-
Barium-selective electrodes based on neutral carriers and their use in the titration of sulphate in combustion products
-
Laeubli M.W., Dinten O., Pretsch E., Simon W. Barium-selective electrodes based on neutral carriers and their use in the titration of sulphate in combustion products. Anal. Chem. 57:1985;2756-2758.
-
(1985)
Anal. Chem.
, vol.57
, pp. 2756-2758
-
-
Laeubli, M.W.1
Dinten, O.2
Pretsch, E.3
Simon, W.4
-
2
-
-
0023123968
-
Barium ion-selective electrode based on the neutral carboxylic polyether antibiotic salinomycin
-
Suzuki K., Tohda K., Sasaliura H., Shirai T. Barium ion-selective electrode based on the neutral carboxylic polyether antibiotic salinomycin. Anal. Lett. 20:1987;39-45.
-
(1987)
Anal. Lett.
, vol.20
, pp. 39-45
-
-
Suzuki, K.1
Tohda, K.2
Sasaliura, H.3
Shirai, T.4
-
3
-
-
0000159076
-
Hetrogeneous ion selective electrodes based on electroneutral ion-carriers: Barium (II) and nickel (II) electrodes
-
Lal U.S., Chattopadhyaya M.C., Dey A.K. Hetrogeneous ion selective electrodes based on electroneutral ion-carriers: barium (II) and nickel (II) electrodes. J. Ind. Chem. Soc. 59:1983;493-496.
-
(1983)
J. Ind. Chem. Soc.
, vol.59
, pp. 493-496
-
-
Lal, U.S.1
Chattopadhyaya, M.C.2
Dey, A.K.3
-
4
-
-
0000836752
-
Characterization of poly(vinyl chloride) barium ion-selective electrodes without and internal reference solution
-
Moody G.J., Thomas J.D.R., Lima J.L.F.C., Machado A.A.S.C. Characterization of poly(vinyl chloride) barium ion-selective electrodes without and internal reference solution. Analyst. 113:1988;1023-1027.
-
(1988)
Analyst
, vol.113
, pp. 1023-1027
-
-
Moody, G.J.1
Thomas, J.D.R.2
Lima, J.L.F.C.3
Machado, A.A.S.C.4
-
5
-
-
0027450120
-
Barium-ion-selective electrode based on a new neutral carrier complex
-
Bouklouze A.A., Vire J.C., Cool V. Barium-ion-selective electrode based on a new neutral carrier complex. Anal. Chim. Acta. 273:1993;153-163.
-
(1993)
Anal. Chim. Acta
, vol.273
, pp. 153-163
-
-
Bouklouze, A.A.1
Vire, J.C.2
Cool, V.3
-
6
-
-
0030260373
-
A barium-selective ferrocene ionophore exhibiting remarkable electrochemical recognition behaviour
-
Moutet J.C., Saint-Aman E., Jon I. A barium-selective ferrocene ionophore exhibiting remarkable electrochemical recognition behaviour. J. Electro. Anal. Chem. 415:1996;187-189.
-
(1996)
J. Electro. Anal. Chem.
, vol.415
, pp. 187-189
-
-
Moutet, J.C.1
Saint-Aman, E.2
Jon, I.3
-
7
-
-
33847802635
-
Preparation and properties of strontium selective electrode
-
Baumann E.W. Preparation and properties of strontium selective electrode. Anal. Chem. 47:1975;959-961.
-
(1975)
Anal. Chem.
, vol.47
, pp. 959-961
-
-
Baumann, E.W.1
-
9
-
-
85008023488
-
A solid membrane electrode for strontium ions
-
Srivastava S.K., Jain C.K. A solid membrane electrode for strontium ions. Bunseki Kagaku. 33:1984;E525-530.
-
(1984)
Bunseki Kagaku
, vol.33
, pp. 525-530
-
-
Srivastava, S.K.1
Jain, C.K.2
-
10
-
-
0001594524
-
Strontium ion selective electrode based on a conducting poly(dibenzo-18-crown-6) film
-
Akmal N., Zimmer H., Mark H.B. Strontium ion selective electrode based on a conducting poly(dibenzo-18-crown-6) film. Anal. Lett. 24:1991;1431-1443.
-
(1991)
Anal. Lett.
, vol.24
, pp. 1431-1443
-
-
Akmal, N.1
Zimmer, H.2
Mark, H.B.3
-
12
-
-
0004146786
-
-
The Royal Society of Chemistry, London
-
C.D. Gutsche, Calixarenes, The Royal Society of Chemistry, London, 1992.
-
(1992)
Calixarenes
-
-
Gutsche, C.D.1
-
13
-
-
0030980259
-
Macrocycle based membrane sensors for the determination of Cobalt(II) ions
-
Jain A.K., Gupta V.K., Singh L.P., Khurana U. Macrocycle based membrane sensors for the determination of Cobalt(II) ions. Analyst. 122:1997;583-586.
-
(1997)
Analyst
, vol.122
, pp. 583-586
-
-
Jain, A.K.1
Gupta, V.K.2
Singh, L.P.3
Khurana, U.4
-
14
-
-
0031131389
-
Nickel(II) selective sensors based on heterogeneous membranes of macrocyclic compounds
-
Jain A.K., Gupta V.K., Singh R.D., Khurana U., Singh L.P. Nickel(II) selective sensors based on heterogeneous membranes of macrocyclic compounds. Sensors and Actuators B. 40:1997;15-20.
-
(1997)
Sensors and Actuators B
, vol.40
, pp. 15-20
-
-
Jain, A.K.1
Gupta, V.K.2
Singh, R.D.3
Khurana, U.4
Singh, L.P.5
-
15
-
-
0347717848
-
Determination and application of ion selective electrode model parameters using flow injection and simplex optimization
-
F.J. Sa'ez de Viteri, D. Diamond, Determination and application of ion selective electrode model parameters using flow injection and simplex optimization. Analyst, 119 (1994) 749-58.
-
(1994)
Analyst
, vol.119
, pp. 749-758
-
-
Sa'ez De Viteri, F.J.1
Diamond, D.2
-
16
-
-
0001562641
-
Neutral carrier and organic resin based membranes as sensors for uranyl ions
-
Jain A.K., Gupta V.K., Singh L.P. Neutral carrier and organic resin based membranes as sensors for uranyl ions. Anal. Proc. 32:1995;263-266.
-
(1995)
Anal. Proc.
, vol.32
, pp. 263-266
-
-
Jain, A.K.1
Gupta, V.K.2
Singh, L.P.3
-
18
-
-
37049083988
-
Determination of lead using poly(vinyl chloride) based crown ether membrane
-
Srivastava S.K., Gupta V.K., Jain S. Determination of lead using poly(vinyl chloride) based crown ether membrane. Analyst. 120:1995;495-498.
-
(1995)
Analyst
, vol.120
, pp. 495-498
-
-
Srivastava, S.K.1
Gupta, V.K.2
Jain, S.3
-
19
-
-
0030668846
-
Porphyrins as carrier in PVC based membrane potentiometric sensor for nickel(II)
-
Gupta V.K., Jain A.K., Singh L.P., Khurana U. Porphyrins as carrier in PVC based membrane potentiometric sensor for nickel(II). Anal. Chim. Acta. 355:1997;33-41.
-
(1997)
Anal. Chim. Acta
, vol.355
, pp. 33-41
-
-
Gupta, V.K.1
Jain, A.K.2
Singh, L.P.3
Khurana, U.4
-
20
-
-
0023754685
-
Guanidinium ion-selective electrodes based on dibenzo-27-crown-9 and tetraphenylborate
-
Assubaie F.N., Moody G.J., Thomas J.D.R. Guanidinium ion-selective electrodes based on dibenzo-27-crown-9 and tetraphenylborate. Analyst. 113:1988;61-64.
-
(1988)
Analyst
, vol.113
, pp. 61-64
-
-
Assubaie, F.N.1
Moody, G.J.2
Thomas, J.D.R.3
-
21
-
-
37049087404
-
Ion selective electrodes in organic analysis : Primary amine selective polymeric membrane electrodes based on a Calix [6] arene ionophore
-
Chan W.H., Shiu K.K., Gu X.H. Ion selective electrodes in organic analysis : primary amine selective polymeric membrane electrodes based on a Calix [6] arene ionophore. Analyst. 118:1993;863-867.
-
(1993)
Analyst
, vol.118
, pp. 863-867
-
-
Chan, W.H.1
Shiu, K.K.2
Gu, X.H.3
|