메뉴 건너뛰기




Volumn 60, Issue 4, 2004, Pages 408-413

Alternating current corrosion risk arising from alternating current-powered rail transit systems on cathodically protected buried steel pipelines and its measures

Author keywords

Alternating current density; Alternating current interference; Alternating current mitigation; Alternating current powered rail transit system; Cathodic protection; Coupon; Induced alternating current; Pipeline

Indexed keywords

CATHODIC PROTECTION; CURRENT DENSITY; ELECTRIC CURRENTS; ELECTRODES; MAGNESIUM PRINTING PLATES; PIPELINES; RISK ASSESSMENT; STEEL;

EID: 2342421314     PISSN: 00109312     EISSN: None     Source Type: Journal    
DOI: 10.5006/1.3287751     Document Type: Article
Times cited : (54)

References (12)
  • 1
    • 84940318718 scopus 로고    scopus 로고
    • AC corrosion induced by VHV electrical lines on polyethylene-coated steel gas pipelines
    • paper no. 557 (Houston, TX: NACE International,)
    • I. Ragault, "AC Corrosion Induced by VHV Electrical Lines on Polyethylene-Coated Steel Gas Pipelines." CORROSION/98. paper no. 557 (Houston, TX: NACE International, 1998).
    • (1998) CORROSION/98
    • Ragault, I.1
  • 2
    • 1642386208 scopus 로고    scopus 로고
    • AC corrosion-case histories, test procedures, and mitigation
    • paper no. 565 (Houston, TX: NACE,)
    • R.G. Wakelin, R.A. Gummow, S.M. Segall. "AC Corrosion-Case Histories, Test Procedures, and Mitigation." CORROSION/98. paper no. 565 (Houston, TX: NACE, 1998).
    • (1998) CORROSION/98
    • Wakelin, R.G.1    Gummow, R.A.2    Segall, S.M.3
  • 3
    • 0042157498 scopus 로고
    • AC-induced corrosion on cathodically protected pipelines
    • W. Printz, "AC-Induced Corrosion on Cathodically Protected Pipelines," UK Corrosion '92 (1992), p. 1.
    • (1992) UK Corrosion '92 , pp. 1
    • Printz, W.1
  • 8
    • 85034052189 scopus 로고    scopus 로고
    • New CP criteria for elimination of the risks of AC corrosion and overprotection on cathodically protected pipelines
    • paper no. 02111 (Houston, TX: NACE)
    • Y. Hosokawa, F. Kajiyama, Y. Nakamura. "New CP Criteria for Elimination of the Risks of AC Corrosion and Overprotection on Cathodically Protected Pipelines," CORROSION/02, paper no. 02111 (Houston, TX: NACE, 2002).
    • (2002) CORROSION/02
    • Hosokawa, Y.1    Kajiyama, F.2    Nakamura, Y.3
  • 10
    • 8344276365 scopus 로고    scopus 로고
    • An innovative instrument for evaluating CP levels liaison with enhanced CP maintenance database
    • paper no. 02112 (Houston, TX: NACE)
    • Y. Hosokawa, F. Kajiyama, Y. Nakamura, "An Innovative Instrument for Evaluating CP Levels Liaison with Enhanced CP Maintenance Database." CORROSION/02. paper no. 02112 (Houston, TX: NACE, 2002).
    • (2002) CORROSION/02
    • Hosokawa, Y.1    Kajiyama, F.2    Nakamura, Y.3
  • 11
    • 2342443219 scopus 로고    scopus 로고
    • Evaluation methods and instrumentation with steel probes used for cathodic protection of underground pipelines
    • F. Kajiyama, "Evaluation Methods and Instrumentation with Steel Probes Used for Cathodic Protection of Underground Pipelines," U.S. Patent no. 6,160.403 (2000).
    • (2000) U.S. Patent No. 6,160.403
    • Kajiyama, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.