New cathodic protection criteria based on direct and alternating current densities measured using coupons and their application to modern steel pipelines

Author keywords

Alternating current corrosion; Alternating current mitigation; Cathodic protection; Coupon; Current density; Overprotection; Pipelines; Stray current corrosion; Stray direct current

Indexed keywords

CATHODIC PROTECTION; COATINGS; SOILS; STEEL;

EID: 1642382045     PISSN: 00109312     EISSN: None     Source Type: Journal    
DOI: 10.5006/1.3287735     Document Type: Article
Times cited : (46)

References (17)
  • 2
    • 8344276365 scopus 로고    scopus 로고
    • An innovative instrument for evaluating CP levels Liaison with enhanced CP maintenance database
    • paper no. 02112 (Houston, TX: NACE International)
    • Y. Hosokawa, F. Kajiyama, Y. Nakamura, "An Innovative Instrument for Evaluating CP Levels Liaison with Enhanced CP Maintenance Database," CORROSION/02, paper no. 02112 (Houston, TX: NACE International, 2002).
    • (2002) CORROSION/02
    • Hosokawa, Y.1    Kajiyama, F.2    Nakamura, Y.3
  • 5
    • 0042157498 scopus 로고
    • AC - Induced corrosion on cathodically protected pipelines
    • W. Printz, "AC-Induced Corrosion on Cathodically Protected Pipelines," UK.Corrosion'92 (1992), p. 1.
    • (1992) UK Corrosion '92 , pp. 1
    • Printz, W.1
  • 6
    • 1642386208 scopus 로고    scopus 로고
    • AC corrosion - Case histories, test procedures, and mitigation
    • paper no. 565 (Houston, TX: NACE)
    • R.G. Wakelin, R.A. Gummow, S.M. Segall, "AC Corrosion-Case Histories, Test Procedures, and Mitigation," CORROSION/98, paper no. 565 (Houston, TX: NACE,1998).
    • (1998) CORROSION/98
    • Wakelin, R.G.1    Gummow, R.A.2    Segall, S.M.3
  • 9
    • 85036611248 scopus 로고    scopus 로고
    • AC corrosion induced by V.H.V. Electrical lines on polyethylene-coated steel gas pipelines
    • paper no. 557 (Houston, TX: NACE)
    • I. Ragault, "AC Corrosion Induced by V.H.V. Electrical Lines on Polyethylene-Coated Steel Gas Pipelines" CORROSION/98, paper no. 557 (Houston, TX: NACE, 1998).
    • (1998) CORROSION/98
    • Ragault, I.1
  • 15
    • 85034052189 scopus 로고    scopus 로고
    • New CP criteria for elimination of the risks of AC corrosion and overprotection on cathodically protected pipelines
    • paper no. 02111 (Houston, TX: NACE)
    • Y. Hosokawa, F. Kajiyama, Y. Nakamura, "New CP Criteria for Elimination of the Risks of AC Corrosion and Overprotection on Cathodically Protected Pipelines," CORROSION/02, paper no. 02111 (Houston, TX: NACE, 2002).
    • (2002) CORROSION/02
    • Hosokawa, Y.1    Kajiyama, F.2    Nakamura, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.