메뉴 건너뛰기




Volumn 23, Issue 7, 1998, Pages 782-788

Multicycle mechanical performance of titanium and stainless steel transpedicular spine implants

Author keywords

Corpectomy model; Fatigue life; Flexure stiffness; Spine implants; Stainless steel; Titanium alloy; Transpedicular

Indexed keywords

POLYETHYLENE; STAINLESS STEEL; TITANIUM;

EID: 0032055996     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-199804010-00008     Document Type: Article
Times cited : (36)

References (25)
  • 1
    • 0023837451 scopus 로고
    • Mechanical testing of spine instrumentation
    • Ashman RB, Birch JG, Bone LB, et al. Mechanical testing of spine instrumentation. Clin Orthop 1988;227:113-25.
    • (1988) Clin Orthop , vol.227 , pp. 113-125
    • Ashman, R.B.1    Birch, J.G.2    Bone, L.B.3
  • 2
    • 0010063965 scopus 로고
    • Metals Park, Ohio: American Society for Metals
    • ASM Metals Reference Book. Metals Park, Ohio: American Society for Metals, 1981;296.
    • (1981) ASM Metals Reference Book , pp. 296
  • 6
    • 0027304350 scopus 로고
    • Static and cyclical biomechanical analysis of pedicle screw spine constructs
    • Cunningham BW, Sefter JC, Shono Y, McAfee PC. Static and cyclical biomechanical analysis of pedicle screw spine constructs. Spine 1993;18:1677-88.
    • (1993) Spine , vol.18 , pp. 1677-1688
    • Cunningham, B.W.1    Sefter, J.C.2    Shono, Y.3    McAfee, P.C.4
  • 8
    • 0026637677 scopus 로고
    • Magnetic resonance imaging after pedicular screw fixation of the spine
    • Ebraheim NA, Savolaine ER, Stitgen SH, Jackson WT. Magnetic resonance imaging after pedicular screw fixation of the spine. Clin Orthop 1992;279:133-7.
    • (1992) Clin Orthop , vol.279 , pp. 133-137
    • Ebraheim, N.A.1    Savolaine, E.R.2    Stitgen, S.H.3    Jackson, W.T.4
  • 11
    • 0024325510 scopus 로고
    • Titanium wire internal fixation for stabilization of injury of the cervical spine: Clinical results and postoperative magnetic resonance imaging of the spine cord
    • Geisler FH, Mirvis SE, Zrebeet J, Joslyn JN. Titanium wire internal fixation for stabilization of injury of the cervical spine: Clinical results and postoperative magnetic resonance imaging of the spine cord. Neurosurgery 1989;25:356-62.
    • (1989) Neurosurgery , vol.25 , pp. 356-362
    • Geisler, F.H.1    Mirvis, S.E.2    Zrebeet, J.3    Joslyn, J.N.4
  • 12
    • 0028842622 scopus 로고
    • Biomechanical testing of the spine: Load-controlled versus displacement-controlled analysis
    • Goel VK, Wilder DG, Pope MH, Edwards WT. Biomechanical testing of the spine: Load-controlled versus displacement-controlled analysis. Spine 1995;20:2354-7.
    • (1995) Spine , vol.20 , pp. 2354-2357
    • Goel, V.K.1    Wilder, D.G.2    Pope, M.H.3    Edwards, W.T.4
  • 13
    • 0028924207 scopus 로고
    • MR imaging evaluation of the spine with titanium alloy pedicular screw fixation
    • Iwasake Y, Yamaguchi Y, Ohi N, Emoto K, Kusakabe T. MR imaging evaluation of the spine with titanium alloy pedicular screw fixation. J Spine Disord 1995;8(Suppl):S15-22.
    • (1995) J Spine Disord , vol.8 , Issue.SUPPL.
    • Iwasake, Y.1    Yamaguchi, Y.2    Ohi, N.3    Emoto, K.4    Kusakabe, T.5
  • 14
    • 0028851966 scopus 로고
    • Effect of spine construct stiffness on short segment fusion mass incorporation
    • Johnston CE, Welch RD, Baker KJ, Ashman RB. Effect of spine construct stiffness on short segment fusion mass incorporation. Spine 1995;20:2400-7.
    • (1995) Spine , vol.20 , pp. 2400-2407
    • Johnston, C.E.1    Welch, R.D.2    Baker, K.J.3    Ashman, R.B.4
  • 15
    • 0025973696 scopus 로고
    • Biomechanics of thoracolumbar spine fixation
    • Krag MH. Biomechanics of thoracolumbar spine fixation. Spine 1991;16(Suppl):S84-99.
    • (1991) Spine , vol.16 , Issue.SUPPL.
    • Krag, M.H.1
  • 16
    • 0025801023 scopus 로고
    • The effect of spinal implant rigidity on vertebral bone density: A canine model
    • McAfee PC, Farey ID, Sutterlin CE, et al. The effect of spinal implant rigidity on vertebral bone density: A canine model. Spine 1991;16(Suppl):S190-7.
    • (1991) Spine , vol.16 , Issue.SUPPL.
    • McAfee, P.C.1    Farey, I.D.2    Sutterlin, C.E.3
  • 17
    • 75949155598 scopus 로고
    • In vivo measurement of intradiscal pressure
    • Nachemson A, Morris JM. In vivo measurement of intradiscal pressure. J Bone Joint Surg [Am] 1964;46:1077-82.
    • (1964) J Bone Joint Surg [Am] , vol.46 , pp. 1077-1082
    • Nachemson, A.1    Morris, J.M.2
  • 18
    • 0013888190 scopus 로고
    • The load on lumbar discs in different positions of the body
    • Nachemson A. The load on lumbar discs in different positions of the body. Clin Orthop 1966;45:107-22.
    • (1966) Clin Orthop , vol.45 , pp. 107-122
    • Nachemson, A.1
  • 21
    • 0024845945 scopus 로고
    • Anterior and posterior cervical spine fixation using titanium implants to facilitate magnetic resonance imaging evaluation
    • Savolaine ER, Ebraheim NA, Andreshak TG, Jackson WT. Anterior and posterior cervical spine fixation using titanium implants to facilitate magnetic resonance imaging evaluation. J Orthop Trauma 1989;3:295-9.
    • (1989) J Orthop Trauma , vol.3 , pp. 295-299
    • Savolaine, E.R.1    Ebraheim, N.A.2    Andreshak, T.G.3    Jackson, W.T.4
  • 22
    • 0028900149 scopus 로고
    • Magnetic resonance imaging of titanium anterior cervical spine plating systems
    • Tominaga T, Shimizu H, Koshu K, Kayama T, Yoshimoto T. Magnetic resonance imaging of titanium anterior cervical spine plating systems. Neurosurgery 1995;36:951-5.
    • (1995) Neurosurgery , vol.36 , pp. 951-955
    • Tominaga, T.1    Shimizu, H.2    Koshu, K.3    Kayama, T.4    Yoshimoto, T.5
  • 23
    • 0028881644 scopus 로고
    • The use of MRI-compatible titanium segmental spine instrumentation in pediatric patients with intraspinal tumor
    • Torpey BM, Dormans JP, Durmmond DS. The use of MRI-compatible titanium segmental spine instrumentation in pediatric patients with intraspinal tumor. J Spine Disord 1995; 8:76-81.
    • (1995) J Spine Disord , vol.8 , pp. 76-81
    • Torpey, B.M.1    Dormans, J.P.2    Durmmond, D.S.3
  • 24
    • 0027300763 scopus 로고
    • A prospective, randomized study of lumbar fusion. Preliminary results
    • Zdeblick TA. A prospective, randomized study of lumbar fusion. Preliminary results. Spine 1993;18:983-91.
    • (1993) Spine , vol.18 , pp. 983-991
    • Zdeblick, T.A.1
  • 25
    • 0022628372 scopus 로고
    • A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine
    • Zindrick MR, Wiltse LL, Widell EH, et al. A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop 1986;203:99-112.
    • (1986) Clin Orthop , vol.203 , pp. 99-112
    • Zindrick, M.R.1    Wiltse, L.L.2    Widell, E.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.