메뉴 건너뛰기




Volumn 12, Issue 2, 2000, Pages 55-59

Surface curvature-based modification as a practical CAD/CAM rectification for transtibial limbs

Author keywords

Artificial limb; Computer aided design; Mechanics; Prosthesis; Rectification; Tissue mechanics

Indexed keywords


EID: 23044523620     PISSN: 10408800     EISSN: None     Source Type: Journal    
DOI: 10.1097/00008526-200012020-00004     Document Type: Article
Times cited : (4)

References (16)
  • 3
    • 0023312048 scopus 로고
    • A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissues
    • Krouskop TA, Dougherty DR, Vinson FS. A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissues. J Rehabil Res Dev. 1987;24:1-8.
    • (1987) J Rehabil Res Dev , vol.24 , pp. 1-8
    • Krouskop, T.A.1    Dougherty, D.R.2    Vinson, F.S.3
  • 5
    • 0001918111 scopus 로고
    • Finite element prediction of pressure at the below-knee socket interface
    • New York: American Society of Mechanical Engineers
    • Steege JW, Schnur DS, Childress DS. Finite Element Prediction of Pressure at the Below-Knee Socket Interface. Biomechanics of Normal and Prosthetic Gait. New York: American Society of Mechanical Engineers; 1987.
    • (1987) Biomechanics of Normal and Prosthetic Gait
    • Steege, J.W.1    Schnur, D.S.2    Childress, D.S.3
  • 7
    • 0342645239 scopus 로고
    • Reflections on CAD/CAM in prosthetics and orthotics
    • Michael JW. Reflections on CAD/CAM in prosthetics and orthotics. J Prosthet Orthot. 1989;1:116-121.
    • (1989) J Prosthet Orthot , vol.1 , pp. 116-121
    • Michael, J.W.1
  • 8
    • 0026924741 scopus 로고
    • Automated fabrication of mobility aids (AFMA): Below-knee CASD/CAM testing and evaluation program results
    • Houston VL. Automated fabrication of mobility aids (AFMA): Below-knee CASD/CAM testing and evaluation program results. J Rehabil Res Dev. 1992;29: 78-124.
    • (1992) J Rehabil Res Dev , vol.29 , pp. 78-124
    • Houston, V.L.1
  • 10
    • 0028483697 scopus 로고
    • Biomechanical assessment of below-knee residual limb tissue
    • Mak AFT, Lui GHW, Lee SY. Biomechanical assessment of below-knee residual limb tissue. J Rehabil Res Dev. 1994;31:188-198.
    • (1994) J Rehabil Res Dev , vol.31 , pp. 188-198
    • Mak, A.F.T.1    Lui, G.H.W.2    Lee, S.Y.3
  • 12
    • 0030200568 scopus 로고    scopus 로고
    • Indentor tests and finite element modeling of bulk muscular tissue
    • Vannah WM, Childress DS. Indentor tests and finite element modeling of bulk muscular tissue. J Rehabil Res Dev. 1996;33:239-252.
    • (1996) J Rehabil Res Dev , vol.33 , pp. 239-252
    • Vannah, W.M.1    Childress, D.S.2
  • 13
    • 0033481844 scopus 로고    scopus 로고
    • Magnetic resonance imaging of residual soft tissues for computer-aided technology applications in prosthetics - A case study
    • Torres-Moreno R, Jones D, Solomonidis SE, Mackie H. Magnetic resonance imaging of residual soft tissues for computer-aided technology applications in prosthetics - A case study. J Prosthet Orthot. 1999;11:6-11.
    • (1999) J Prosthet Orthot , vol.11 , pp. 6-11
    • Torres-Moreno, R.1    Jones, D.2    Solomonidis, S.E.3    Mackie, H.4
  • 14
    • 0027751317 scopus 로고
    • Modelling the mechanics of narrowly contained soft tissues: The effect of specification of Poisson's ratio
    • Vannah WM, Childress DS. Modelling the mechanics of narrowly contained soft tissues: The effect of specification of Poisson's ratio. J Rehabil Res Dev. 1993;30:205-209.
    • (1993) J Rehabil Res Dev , vol.30 , pp. 205-209
    • Vannah, W.M.1    Childress, D.S.2
  • 15
    • 3643077386 scopus 로고
    • Sockets, linings, and interfaces
    • Murphy EF. Sockets, linings, and interfaces. Clin Prosthet Orthot. 1984;8:4-10.
    • (1984) Clin Prosthet Orthot , vol.8 , pp. 4-10
    • Murphy, E.F.1
  • 16
    • 0025346642 scopus 로고
    • Biomechanics and the shape of the above-knee socket considered in light of the ischial containment concept
    • Pritham CH. Biomechanics and the shape of the above-knee socket considered in light of the ischial containment concept. Prosthet Orthot Int. 1990;14:9-21.
    • (1990) Prosthet Orthot Int , vol.14 , pp. 9-21
    • Pritham, C.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.