메뉴 건너뛰기




Volumn 10, Issue 1, 1998, Pages 2-6

Frequency content of prosthetic and onthotic shapes: A requirement for CAD/CAM digitizer performance

Author keywords

Artificial Limb; Computer Aided Design; Frequency Analysis; Orthosis; Prosthesis

Indexed keywords


EID: 0032338223     PISSN: 10408800     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (13)
  • 1
    • 0029028851 scopus 로고
    • Validation of spiral CT and optical surface scanning for lower limb stump volumetry
    • Smith KE, Commean PK, Bhatia G, Vannier MW. Validation of spiral CT and optical surface scanning for lower limb stump volumetry. Pros Orth Int 1995;19:97-107.
    • (1995) Pros Orth Int , vol.19 , pp. 97-107
    • Smith, K.E.1    Commean, P.K.2    Bhatia, G.3    Vannier, M.W.4
  • 3
    • 0029043206 scopus 로고
    • Volumetric determinations with CAD/CAM in prosthetics and orthotics: Errors in measurement
    • Lilja M, Oberg T. Volumetric determinations with CAD/CAM in prosthetics and orthotics: Errors in measurement. J Rehab R&D 1995;32:141-8.
    • (1995) J Rehab R&D , vol.32 , pp. 141-148
    • Lilja, M.1    Oberg, T.2
  • 4
    • 0030199723 scopus 로고    scopus 로고
    • Clinical analysis of a CAD/CAM system for custom seating: A comparison with hand-sculpting methods
    • Lemaire ED, Upton D, Paialunga J, Martel G, Boucher J. Clinical analysis of a CAD/CAM system for custom seating: A comparison with hand-sculpting methods. J Rehab R&D 1996;33:311-20.
    • (1996) J Rehab R&D , vol.33 , pp. 311-320
    • Lemaire, E.D.1    Upton, D.2    Paialunga, J.3    Martel, G.4    Boucher, J.5
  • 7
    • 3643071059 scopus 로고
    • Development and clinical trial of the UCL computer-aided socket design system
    • University College, London
    • Dewar M, Jarman P, Reynolds D, Jones K. Development and clinical trial of the UCL computer-aided socket design system. Bioengineering Centre Report 1986, University College, London, 11-16.
    • (1986) Bioengineering Centre Report , pp. 11-16
    • Dewar, M.1    Jarman, P.2    Reynolds, D.3    Jones, K.4
  • 12
    • 0342645239 scopus 로고
    • Reflections on CAD/ CAM in prosthetics and orthotics
    • Michael JW. Reflections on CAD/ CAM in prosthetics and orthotics. JPO 1989;1:116-21.
    • (1989) JPO , vol.1 , pp. 116-121
    • Michael, J.W.1
  • 13
    • 0026924741 scopus 로고
    • Automated fabrication of mobility aids: Below-knee CASM/CAM testing and evaluation program results
    • Houston VL Automated fabrication of mobility aids: Below-knee CASM/CAM testing and evaluation program results. J Rehab R&D 1992;29:78-124.
    • (1992) J Rehab R&D , vol.29 , pp. 78-124
    • Houston, V.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.