메뉴 건너뛰기




Volumn 50, Issue 8, 2005, Pages 1821-1836

A numerical study of transcranial focused ultrasound beam propagation at low frequency

Author keywords

[No Author keywords available]

Indexed keywords

ABERRATIONS; ACOUSTIC WAVES; BRAIN; COMPUTER SIMULATION; NATURAL FREQUENCIES; STEERING;

EID: 22844452715     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/50/8/013     Document Type: Article
Times cited : (87)

References (37)
  • 1
    • 0030099527 scopus 로고    scopus 로고
    • Transporting therapeutics across the blood-brain barrier
    • Abbott N J and Romero I A 1996 Transporting therapeutics across the blood-brain barrier Mol. Med. Today 2 106-13
    • (1996) Mol. Med. Today , vol.2 , pp. 106-113
    • Abbott, N.J.1    Romero, I.A.2
  • 2
    • 1642279961 scopus 로고    scopus 로고
    • Ultrasound-enhanced thrombolysis for acute ischemic stroke: Phase I. Findings of the CLOTBUST trial
    • Alexandrov A V, Demchuk A M, Burgin W S, Robinson D J, Grotta J C and CLOTBUST investigators 2004 Ultrasound-enhanced thrombolysis for acute ischemic stroke: phase I. Findings of the CLOTBUST trial J. Neuroimaging 14 113-7
    • (2004) J. Neuroimaging , vol.14 , pp. 113-117
    • Alexandrov, A.V.1    Demchuk, A.M.2    Burgin, W.S.3    Robinson, D.J.4    Grotta, J.C.5
  • 3
    • 0037237319 scopus 로고    scopus 로고
    • Experimental demonstration of noninvasive transskull adaptive focusing based on prior computer tomography scans
    • Aubry J F, Tanter M, Pernot M, Thomas J-L and Fink M A 2003 Experimental demonstration of noninvasive transskull adaptive focusing based on prior computer tomography scans J. Acoust. Soc. Am. 113 84-93
    • (2003) J. Acoust. Soc. Am. , vol.113 , pp. 84-93
    • Aubry, J.F.1    Tanter, M.2    Pernot, M.3    Thomas, J.-L.4    Fink, M.A.5
  • 5
    • 0033084089 scopus 로고    scopus 로고
    • Low-frequency, low-intensity ultrasound accelerates thrombolysis through the skull
    • Behrens S, Spiegel D, Daffertshofer M and Hennerici M 1999 Low-frequency, low-intensity ultrasound accelerates thrombolysis through the skull Ultrasound Med. Biol. 25 267-73
    • (1999) Ultrasound Med. Biol. , vol.25 , pp. 267-273
    • Behrens, S.1    Spiegel, D.2    Daffertshofer, M.3    Hennerici, M.4
  • 6
    • 0034580048 scopus 로고    scopus 로고
    • Criteria for the design and characterization of large-area arrays for transskull ultrasound surgery and therapy
    • Clement G T and Hynynen K 2000 Criteria for the design and characterization of large-area arrays for transskull ultrasound surgery and therapy Prof. Ultrason. Symp. pp 1243-6
    • (2000) Prof. Ultrason. Symp. , pp. 1243-1246
    • Clement, G.T.1    Hynynen, K.2
  • 8
    • 0037149993 scopus 로고    scopus 로고
    • A non-invasive method for focusing ultrasound through the human skull
    • Clement G T and Hynynen K 2002b A non-invasive method for focusing ultrasound through the human skull Phys. Med. Biol. 47 1219-36
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1219-1236
    • Clement, G.T.1    Hynynen, K.2
  • 9
    • 0034535714 scopus 로고    scopus 로고
    • A hemisphere array for non-invasive ultrasound brain therapy and surgery
    • Clement G T, Sun J, Giesecke T and Hynynen K 2000a A hemisphere array for non-invasive ultrasound brain therapy and surgery Phys. Med. Biol. 45 3707-19
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3707-3719
    • Clement, G.T.1    Sun, J.2    Giesecke, T.3    Hynynen, K.4
  • 10
    • 0034118591 scopus 로고    scopus 로고
    • Investigation of a large-area phased array for focused ultrasound surgery through the skull
    • Clement G T, White J P and Hynynen K 2000b Investigation of a large-area phased array for focused ultrasound surgery through the skull Phys. Med. Biol. 45 1071-83
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1071-1083
    • Clement, G.T.1    White, J.P.2    Hynynen, K.3
  • 11
    • 0036858483 scopus 로고    scopus 로고
    • Therapeutic ultrasound in ischemic stroke treatment: Experimental evidence
    • Daffertshofer M and Fatar M 2002 Therapeutic ultrasound in ischemic stroke treatment: experimental evidence Eur. J. Ultrasound 16 121-30
    • (2002) Eur. J. Ultrasound , vol.16 , pp. 121-130
    • Daffertshofer, M.1    Fatar, M.2
  • 13
    • 0017752994 scopus 로고
    • Transskull transmission of an intensely focused ultrasonic beam
    • Fry F J 1977 Transskull transmission of an intensely focused ultrasonic beam Ultrasound Med. Biol. 3 179-84
    • (1977) Ultrasound Med. Biol. , vol.3 , pp. 179-184
    • Fry, F.J.1
  • 14
    • 0017964432 scopus 로고
    • Acoustic properties of the human skull
    • Fry F J and Barger J E 1978 Acoustic properties of the human skull J. Acoust. Soc. Am. 63 1576-90
    • (1978) J. Acoust. Soc. Am. , vol.63 , pp. 1576-1590
    • Fry, F.J.1    Barger, J.E.2
  • 15
    • 0018874098 scopus 로고
    • Further studies of the transskull transmission of an intense focused ultrasonic beam: Lesion production at 500 kHz
    • Fry F J and Goss S A 1980 Further studies of the transskull transmission of an intense focused ultrasonic beam: lesion production at 500 kHz Ultrasound Med. Biol. 6 33-8
    • (1980) Ultrasound Med. Biol. , vol.6 , pp. 33-38
    • Fry, F.J.1    Goss, S.A.2
  • 20
    • 0025810360 scopus 로고
    • Treatment of malignant brain tumors with focused ultrasound hyperthermia and radiation: Results of a phase I trial
    • Guthkelch A et al 1991b Treatment of malignant brain tumors with focused ultrasound hyperthermia and radiation: results of a phase I trial J. Neurooncol. 10 271-84
    • (1991) J. Neurooncol. , vol.10 , pp. 271-284
    • Guthkelch, A.1
  • 21
    • 0029974783 scopus 로고    scopus 로고
    • Design and optimization of an aperiodic ultrasound phased array for intracavitary prostate thermal therapies
    • Hutchinson E B, Buchanan M T and Hynynen K 1996 Design and optimization of an aperiodic ultrasound phased array for intracavitary prostate thermal therapies Med. Phys. 23 767-76
    • (1996) Med. Phys. , vol.23 , pp. 767-776
    • Hutchinson, E.B.1    Buchanan, M.T.2    Hynynen, K.3
  • 22
    • 0026090542 scopus 로고
    • The threshold for thermally significant cavitation in dog's thigh muscle in vivo
    • Hynynen K 1991 The threshold for thermally significant cavitation in dog's thigh muscle in vivo Ultrasound Med. Biol. 17 157-69
    • (1991) Ultrasound Med. Biol. , vol.17 , pp. 157-169
    • Hynynen, K.1
  • 23
    • 4644312297 scopus 로고    scopus 로고
    • 500-Element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls
    • Hynynen K, Clement G T, McDannold N, Vykhodtseva N, King R, White P J, Vitek S and Jolesz F A 2004 500-Element ultrasound phased array system for noninvasive focal surgery of the brain: a preliminary rabbit study with ex vivo human skulls Magn. Reson. Med. 52 100-107
    • (2004) Magn. Reson. Med. , vol.52 , pp. 100-107
    • Hynynen, K.1    Clement, G.T.2    McDannold, N.3    Vykhodtseva, N.4    King, R.5    White, P.J.6    Vitek, S.7    Jolesz, F.A.8
  • 24
    • 0032005450 scopus 로고    scopus 로고
    • Demonstration of potential noninvasive ultrasound brain therapy through an intact skull
    • Hynynen K and Jolesz F A 1998 Demonstration of potential noninvasive ultrasound brain therapy through an intact skull Ultrasound Med. Biol. 24 275-83
    • (1998) Ultrasound Med. Biol. , vol.24 , pp. 275-283
    • Hynynen, K.1    Jolesz, F.A.2
  • 25
    • 0037361542 scopus 로고    scopus 로고
    • The threshold for brain damage in rabbits induced by bursts of ultrasound in the presence of an ultrasound contrast agent (Optison)
    • Hynynen K, McDannold N, Martin H, Jolesz F A and Vykhodtseva N 2003 The threshold for brain damage in rabbits induced by bursts of ultrasound in the presence of an ultrasound contrast agent (Optison) Ultrasound Med. Biol. 29 473-81
    • (2003) Ultrasound Med. Biol. , vol.29 , pp. 473-481
    • Hynynen, K.1    McDannold, N.2    Martin, H.3    Jolesz, F.A.4    Vykhodtseva, N.5
  • 26
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen K, McDannold N, Vykhodtseva N and Jolesz F A 2001 Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits Radiology 220 640-46
    • (2001) Radiology , vol.220 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 27
    • 0000933610 scopus 로고    scopus 로고
    • Trans-skull ultrasound therapy: The feasibility of using image-derived skull thickness information to correct the phase distortion
    • Hynynen K and Sun J 1999 Trans-skull ultrasound therapy: the feasibility of using image-derived skull thickness information to correct the phase distortion IEEE Trans. Ultrason. Ferroelectr. Freq. Control 46 752
    • (1999) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.46 , pp. 752
    • Hynynen, K.1    Sun, J.2
  • 29
    • 33845416619 scopus 로고
    • A new method for the generation and use of focused ultrasound in experimental biology
    • Lynn J G, Zwemer R L, Chick A J and Miller A E 1942 A new method for the generation and use of focused ultrasound in experimental biology J. Gen. Physiol. 26 179-93
    • (1942) J. Gen. Physiol. , vol.26 , pp. 179-193
    • Lynn, J.G.1    Zwemer, R.L.2    Chick, A.J.3    Miller, A.E.4
  • 32
    • 0031694165 scopus 로고    scopus 로고
    • Focusing of therapeutic ultrasound through a human skull: A numerical study
    • Sun J and Hynynen K 1998 Focusing of therapeutic ultrasound through a human skull: a numerical study J. Acoust. Soc. Am. 104 1705-15
    • (1998) J. Acoust. Soc. Am. , vol.104 , pp. 1705-1715
    • Sun, J.1    Hynynen, K.2
  • 33
    • 0033044247 scopus 로고    scopus 로고
    • The potential of transskull ultrasound therapy and surgery using the maximum available skull surface area
    • Sun J and Hynynen K 1999 The potential of transskull ultrasound therapy and surgery using the maximum available skull surface area J. Acoust. Soc. Am. 105 2519-27
    • (1999) J. Acoust. Soc. Am. , vol.105 , pp. 2519-2527
    • Sun, J.1    Hynynen, K.2
  • 34
    • 0030289227 scopus 로고    scopus 로고
    • Ultrasonic beam focusing through tissue inhomogeneities with a time reversal mirror: Application to transskull therapy
    • Thomas J-L and Fink M A 1996 Ultrasonic beam focusing through tissue inhomogeneities with a time reversal mirror: application to transskull therapy IEEE Trans. Ultrason. Ferroelectr. Freq. Control 43 1122-9
    • (1996) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.43 , pp. 1122-1129
    • Thomas, J.-L.1    Fink, M.A.2
  • 35
    • 0029148503 scopus 로고
    • Histologic effects of high intensity pulsed ultrasound exposure with subharmonic emission in rabbit brain in vivo
    • Vykhodtseva N, Hynynen K and Damianou C 1995 Histologic effects of high intensity pulsed ultrasound exposure with subharmonic emission in rabbit brain in vivo Ultrasound Med. Biol. 21 969-79
    • (1995) Ultrasound Med. Biol. , vol.21 , pp. 969-979
    • Vykhodtseva, N.1    Hynynen, K.2    Damianou, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.