메뉴 건너뛰기




Volumn 21, Issue 8, 2005, Pages 761-772

Effect of water storage, thermocycling, the incorporation and site of placement of glass-fibers on the flexural strength of veneering composite

Author keywords

Dental materials composite resin; Fine hybrid; Flexural strength; Glass fiber re enforcement; Microfilled; Water storage

Indexed keywords

BENDING STRENGTH; FILLERS; GLASS FIBERS; RESINS; TENSILE TESTING; THERMAL CYCLING;

EID: 22344432546     PISSN: 01095641     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dental.2005.01.013     Document Type: Article
Times cited : (47)

References (26)
  • 1
    • 85047675946 scopus 로고    scopus 로고
    • Resin-bonded, glass-fiber reinforced composite fixed partial dentures: A clinical study
    • P.K. Vallittu, and C. Sevelius Resin-bonded, glass-fiber reinforced composite fixed partial dentures: a clinical study J Prosthet Dent 84 2000 413 418
    • (2000) J Prosthet Dent , vol.84 , pp. 413-418
    • Vallittu, P.K.1    Sevelius, C.2
  • 3
    • 0036463393 scopus 로고    scopus 로고
    • Two-year clinical and SEM evaluation of glass-fiber-reinforced inlay fixed partial dentures
    • T.N. Göhring, P.R. Schmidlin, and F. Lutz Two-year clinical and SEM evaluation of glass-fiber-reinforced inlay fixed partial dentures Am J Dent 15 2002 35 40
    • (2002) Am J Dent , vol.15 , pp. 35-40
    • Göhring, T.N.1    Schmidlin, P.R.2    Lutz, F.3
  • 4
    • 0141498418 scopus 로고    scopus 로고
    • Fiber-reinforced composite crowns and FPDs: A clinical report
    • M. Behr, M. Rosentritt, and G. Handel Fiber-reinforced composite crowns and FPDs: a clinical report Int J Prosthodont 16 2003 239 243
    • (2003) Int J Prosthodont , vol.16 , pp. 239-243
    • Behr, M.1    Rosentritt, M.2    Handel, G.3
  • 5
    • 0020842592 scopus 로고
    • A classification and evaluation of composite Resin systems
    • F. Lutz, and R.W. Phillips A classification and evaluation of composite Resin systems J Prosthet Dent 50 1983 480 488
    • (1983) J Prosthet Dent , vol.50 , pp. 480-488
    • Lutz, F.1    Phillips, R.W.2
  • 6
    • 0031598448 scopus 로고    scopus 로고
    • Influence of UEDMA, BisGMA and TEGDMA on selected mechanical properties of experimental resin composites
    • E. Asmussen, and A. Peutzfeldt Influence of UEDMA, BisGMA and TEGDMA on selected mechanical properties of experimental resin composites Dent Mater 14 1998 51 56
    • (1998) Dent Mater , vol.14 , pp. 51-56
    • Asmussen, E.1    Peutzfeldt, A.2
  • 7
  • 8
    • 0034242970 scopus 로고    scopus 로고
    • The effect of postcuring on quantity of remaining double bonds, mechanical properties, and in vitro wear of two resins composites
    • A. Peutzfeldt, and E. Asmussen The effect of postcuring on quantity of remaining double bonds, mechanical properties, and in vitro wear of two resins composites J Dent 28 2000 447 452
    • (2000) J Dent , vol.28 , pp. 447-452
    • Peutzfeldt, A.1    Asmussen, E.2
  • 9
    • 22344442509 scopus 로고
    • The clinical evaluation of heat-treated composites
    • S.L. Wendt, and K.F. Leinfelder The clinical evaluation of heat-treated composites J Am Dent Assoc 71 1990 13 19
    • (1990) J Am Dent Assoc , vol.71 , pp. 13-19
    • Wendt, S.L.1    Leinfelder, K.F.2
  • 10
    • 0031308176 scopus 로고    scopus 로고
    • Second generation laboratory composite resins for indirect restorations
    • B. Touati, and N. Aidan Second generation laboratory composite resins for indirect restorations J Esthet Dent 9 1997 108 118
    • (1997) J Esthet Dent , vol.9 , pp. 108-118
    • Touati, B.1    Aidan, N.2
  • 11
    • 0032192964 scopus 로고    scopus 로고
    • Treatment considerations for posterior laboratory-fabricated composite resin restorations
    • P.R. Chalifoux Treatment considerations for posterior laboratory-fabricated composite resin restorations Pract Periodontics Aesthet Dent 10 1998 969 978
    • (1998) Pract Periodontics Aesthet Dent , vol.10 , pp. 969-978
    • Chalifoux, P.R.1
  • 12
    • 0025469412 scopus 로고
    • Fatigue and wear of dental material
    • C.N. Reid, J. Fisher, and P.H. Jacobsen Fatigue and wear of dental material J Dent 18 1990 209 215
    • (1990) J Dent , vol.18 , pp. 209-215
    • Reid, C.N.1    Fisher, J.2    Jacobsen, P.H.3
  • 13
    • 0028418045 scopus 로고
    • Clinical relevance of laboratory fatigue studies
    • M. Braem, P. Lambrechts, and G. Vanherle Clinical relevance of laboratory fatigue studies J Dent 22 1994 97 102
    • (1994) J Dent , vol.22 , pp. 97-102
    • Braem, M.1    Lambrechts, P.2    Vanherle, G.3
  • 15
    • 0037763332 scopus 로고
    • International Standard Organization No. 4049 Geneva: International Organization for Standardization S.p.
    • International Standard Organization No. 4049. Dentistry - resin-based filling materials. Geneva: International Organization for Standardization; 1992. S.p.
    • (1992) Dentistry - Resin-based Filling Materials
  • 16
    • 0022764778 scopus 로고
    • A statistical approach to the mechanical testing of dental materials
    • J.F. McCabe, and T.E. Carrick A statistical approach to the mechanical testing of dental materials Dent Mater 2 1986 139 142
    • (1986) Dent Mater , vol.2 , pp. 139-142
    • McCabe, J.F.1    Carrick, T.E.2
  • 17
    • 0035433572 scopus 로고    scopus 로고
    • The influence of fibre placement and position on the efficiency of reinforcement of fibre reinforced composite bridgework
    • A.E. Ellakwa, A.C. Shortall, M.K. Shehata, and P.M. Marquis The influence of fibre placement and position on the efficiency of reinforcement of fibre reinforced composite bridgework J Oral Rehabil 28 2001 785 791
    • (2001) J Oral Rehabil , vol.28 , pp. 785-791
    • Ellakwa, A.E.1    Shortall, A.C.2    Shehata, M.K.3    Marquis, P.M.4
  • 18
    • 0036121228 scopus 로고    scopus 로고
    • The influence of short-term waterstorage on the flexural properties of unidirectional glass-fiber reinforced composites
    • L.V. Lassila, T. Nohrström, and P.K. Vallittu The influence of short-term waterstorage on the flexural properties of unidirectional glass-fiber reinforced composites Biomaterials 23 2002 2221 2229
    • (2002) Biomaterials , vol.23 , pp. 2221-2229
    • Lassila, L.V.1    Nohrström, T.2    Vallittu, P.K.3
  • 19
    • 0035431449 scopus 로고    scopus 로고
    • Influence of thermal cycles in water on flexural strength of laboratory-processed composite resin
    • F. Kawano, T. Ohguri, T. Ichikawa, and N. Matsumoto Influence of thermal cycles in water on flexural strength of laboratory-processed composite resin J Oral Rehabil 28 2001 703 707
    • (2001) J Oral Rehabil , vol.28 , pp. 703-707
    • Kawano, F.1    Ohguri, T.2    Ichikawa, T.3    Matsumoto, N.4
  • 21
    • 0038970641 scopus 로고    scopus 로고
    • Influence of shade and storage time on the flexural strength, flexural modulus, and hardness of composites used for indirect restorations
    • P.F. Cesar, W.G. Miranda Jr, and R.R. Braga Influence of shade and storage time on the flexural strength, flexural modulus, and hardness of composites used for indirect restorations J Prosthet Dent 86 2001 289 296
    • (2001) J Prosthet Dent , vol.86 , pp. 289-296
    • Cesar, P.F.1    Miranda Jr., W.G.2    Braga, R.R.3
  • 22
    • 0032488231 scopus 로고    scopus 로고
    • In vitro aging of dental composites in water - Effect of degree of conversion, filler volume, and filler/matrix coupling
    • J.L. Ferracane, H.X. Berge, and J.R. Condon In vitro aging of dental composites in water - effect of degree of conversion, filler volume, and filler/matrix coupling J Biomed Mater Res 42 1998 465 472
    • (1998) J Biomed Mater Res , vol.42 , pp. 465-472
    • Ferracane, J.L.1    Berge, H.X.2    Condon, J.R.3
  • 23
    • 0029311862 scopus 로고
    • Relationship between particle size of barium glass filler and water sorption of light polymerized composite resin
    • H. Tarumi, M. Torli, and Y. Tsuchitani Relationship between particle size of barium glass filler and water sorption of light polymerized composite resin Dent Mater J 14 1995 37 44
    • (1995) Dent Mater J , vol.14 , pp. 37-44
    • Tarumi, H.1    Torli, M.2    Tsuchitani, Y.3
  • 24
    • 0019633948 scopus 로고
    • Degradation of glass filler in experimental composites
    • K.J. Soderholm Degradation of glass filler in experimental composites J Dent Res 60 1981 1867 1875
    • (1981) J Dent Res , vol.60 , pp. 1867-1875
    • Soderholm, K.J.1
  • 25
    • 0029335996 scopus 로고
    • Fracture toughness of experimental dental composites aged in ethanol
    • J.L. Ferracane, and H.X. Berge Fracture toughness of experimental dental composites aged in ethanol J Dent Res 74 1995 1418 1423
    • (1995) J Dent Res , vol.74 , pp. 1418-1423
    • Ferracane, J.L.1    Berge, H.X.2
  • 26
    • 0034266653 scopus 로고    scopus 로고
    • Flexural properties of fiber reinforced composite using a vacuum/pressure or a manual adaptation manufacturing process
    • M. Behr, M. Rosentritt, R. Lang, and G. Handel Flexural properties of fiber reinforced composite using a vacuum/pressure or a manual adaptation manufacturing process J Dent 28 2000 509 514
    • (2000) J Dent , vol.28 , pp. 509-514
    • Behr, M.1    Rosentritt, M.2    Lang, R.3    Handel, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.