In vitro evaluation of bronchodilator drug delivery by jet nebulization during pediatric mechanical ventilation

Author keywords

Aerosols; Drug delivery; Infant; Jet nebulizer; Mechanical ventilation; Particle size distribution

Indexed keywords

BRONCHODILATING AGENT; SALBUTAMOL;

EID: 22144446795     PISSN: 15297535     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.PCC.0000162452.68144.27     Document Type: Article
Times cited : (12)

References (36)
  • 1
    • 0030927781 scopus 로고    scopus 로고
    • Nebuliser therapy in the intensive care unit
    • O'Doherty MJ, Thomas SHL: Nebuliser therapy in the intensive care unit. Thorax 1997; 52(Suppl 2):S56-S59
    • (1997) Thorax , vol.52 , Issue.SUPPL. 2
    • O'Doherty, M.J.1    Thomas, S.H.L.2
  • 2
    • 0031903277 scopus 로고    scopus 로고
    • Aerosolized albuterol improves airway reactivity in infants with acute respiratory failure from respiratory syncytial virus
    • Derish M, Hodge G, Dunn C, et al: Aerosolized albuterol improves airway reactivity in infants with acute respiratory failure from respiratory syncytial virus. Pediatr Pulmonol 1998; 26:12-20
    • (1998) Pediatr Pulmonol , vol.26 , pp. 12-20
    • Derish, M.1    Hodge, G.2    Dunn, C.3
  • 3
    • 0037998152 scopus 로고    scopus 로고
    • Efficiency of aerosol medication delivery from a metered-dose inhaler versus jet nebulizer in infants with bronchopulmonary dysplasia
    • Fok TF, Monkman S, Dolovich M, et al: Efficiency of aerosol medication delivery from a metered-dose inhaler versus jet nebulizer in infants with bronchopulmonary dysplasia. Pediatr Pulmonol 1996; 21:301-309
    • (1996) Pediatr Pulmonol , vol.21 , pp. 301-309
    • Fok, T.F.1    Monkman, S.2    Dolovich, M.3
  • 4
    • 4644343918 scopus 로고    scopus 로고
    • Basic techniques for aerosol delivery during mechanical ventilation
    • Dhand R: Basic techniques for aerosol delivery during mechanical ventilation. Respir Care 2004; 49:611-622
    • (2004) Respir Care , vol.49 , pp. 611-622
    • Dhand, R.1
  • 5
    • 4644332315 scopus 로고    scopus 로고
    • New frontiers in aerosol delivery during mechanical ventilation
    • Dhand R: New frontiers in aerosol delivery during mechanical ventilation. Respir Care 2004; 49:666-677
    • (2004) Respir Care , vol.49 , pp. 666-677
    • Dhand, R.1
  • 6
    • 0030982725 scopus 로고    scopus 로고
    • Current best practice for nebulizer treatment
    • British Thoracic Society Nebulizer Project Group
    • Anonymous: British Thoracic Society Nebulizer Project Group. Current best practice for nebulizer treatment. Thorax 1997; 52(Suppl 2):S1-S24
    • (1997) Thorax , vol.52 , Issue.SUPPL. 2
  • 7
    • 0027972601 scopus 로고
    • Inhaled bronchodilators during mechanical ventilation: Delivery techniques, evaluation of response, and cost-effectiveness
    • Hess D: Inhaled bronchodilators during mechanical ventilation: Delivery techniques, evaluation of response, and cost-effectiveness. Respir Care 1994; 39:105-122
    • (1994) Respir Care , vol.39 , pp. 105-122
    • Hess, D.1
  • 8
    • 0029929796 scopus 로고    scopus 로고
    • Therapeutic aerosol delivery during mechanical ventilation
    • Coleman DM, Kelly HW, McWilliams BC: Therapeutic aerosol delivery during mechanical ventilation. Ann Pharmacother 1996; 30: 644-655
    • (1996) Ann Pharmacother , vol.30 , pp. 644-655
    • Coleman, D.M.1    Kelly, H.W.2    McWilliams, B.C.3
  • 9
    • 0028234112 scopus 로고
    • Evaluation of a prototype expiratory-phase aerosol controller during simulated pediatric volume-controlled ventilation
    • Keenan J, Salyer JW: Evaluation of a prototype expiratory-phase aerosol controller during simulated pediatric volume-controlled ventilation. Respir Care 1994; 39:617-622
    • (1994) Respir Care , vol.39 , pp. 617-622
    • Keenan, J.1    Salyer, J.W.2
  • 10
    • 0141591206 scopus 로고    scopus 로고
    • Clinical practice guideline: Selection of device, administration of bronchodilator, and evaluation of response to therapy in mechanically ventilated patients
    • American Association of Respiratory Care: Clinical practice guideline: Selection of device, administration of bronchodilator, and evaluation of response to therapy in mechanically ventilated patients. Respir Care 1999; 44:105-113
    • (1999) Respir Care , vol.44 , pp. 105-113
  • 11
    • 0033840918 scopus 로고    scopus 로고
    • Aerosol therapy in mechanically ventilated patients: Recent advances and new techniques
    • Fink JB, Dhand R: Aerosol therapy in mechanically ventilated patients: Recent advances and new techniques. Semin Respir Crit Care Med 2000; 21:183-201
    • (2000) Semin Respir Crit Care Med , vol.21 , pp. 183-201
    • Fink, J.B.1    Dhand, R.2
  • 12
    • 0031890269 scopus 로고    scopus 로고
    • Suboptimal use of inhaled aerosol therapy during mechanical ventilation in intensive therapy units in the UK and Ireland
    • Thomas SHL, Page CJ, Barrington SF, et al: Suboptimal use of inhaled aerosol therapy during mechanical ventilation in intensive therapy units in the UK and Ireland. Br J Anaesth 1998; 80:274
    • (1998) Br J Anaesth , vol.80 , pp. 274
    • Thomas, S.H.L.1    Page, C.J.2    Barrington, S.F.3
  • 13
    • 85010119593 scopus 로고
    • Controlled aerosol delivery during mechanical ventilation
    • Dahlbäck M, Wollmer P, Drefeldt B, et al: Controlled aerosol delivery during mechanical ventilation. J Aerosol Med 1989; 2:339-347
    • (1989) J Aerosol Med , vol.2 , pp. 339-347
    • Dahlbäck, M.1    Wollmer, P.2    Drefeldt, B.3
  • 14
    • 0025376424 scopus 로고
    • Evaluation of nebulizers for use in neonatal ventilator circuits
    • Cameron D, Clay M, Silverman M: Evaluation of nebulizers for use in neonatal ventilator circuits. Crit Care Med 1990; 18: 866-870
    • (1990) Crit Care Med , vol.18 , pp. 866-870
    • Cameron, D.1    Clay, M.2    Silverman, M.3
  • 15
    • 0025755299 scopus 로고
    • The impact of changing ventilator parameters on availability of nebulized drugs in an in vitro neonatal lung system
    • Benson JM, Gal P, Kandrotas RJ, et al: The impact of changing ventilator parameters on availability of nebulized drugs in an in vitro neonatal lung system. Ann Pharmacother 1991; 25:272-275
    • (1991) Ann Pharmacother , vol.25 , pp. 272-275
    • Benson, J.M.1    Gal, P.2    Kandrotas, R.J.3
  • 16
    • 0026747337 scopus 로고
    • Comparison of nebulizer delivery methods through a neonatal endotracheal tube: A bench study
    • Rau JL, Harwood RJ: Comparison of nebulizer delivery methods through a neonatal endotracheal tube: a bench study. Respir Care 1992; 37:1233-1240
    • (1992) Respir Care , vol.37 , pp. 1233-1240
    • Rau, J.L.1    Harwood, R.J.2
  • 17
    • 0026896251 scopus 로고
    • Delivery of micronized budesonide suspension by metered dose inhaler and jet nebulizer in a neonatal ventilator circuit
    • Arnon S, Grigg J, Nikander K, et al: Delivery of micronized budesonide suspension by metered dose inhaler and jet nebulizer in a neonatal ventilator circuit. Pediatr Pulmonol 1992; 13:172-175
    • (1992) Pediatr Pulmonol , vol.13 , pp. 172-175
    • Arnon, S.1    Grigg, J.2    Nikander, K.3
  • 18
    • 0030011457 scopus 로고    scopus 로고
    • Determinants of aerosolized albuterol delivery to mechanically ventilated infants
    • Coleman DM, Kelly HW, McWilliams BC: Determinants of aerosolized albuterol delivery to mechanically ventilated infants. Chest 1996; 109:1607-1613
    • (1996) Chest , vol.109 , pp. 1607-1613
    • Coleman, D.M.1    Kelly, H.W.2    McWilliams, B.C.3
  • 19
    • 0032980469 scopus 로고    scopus 로고
    • Evaluating the delivery of nebulized and metered-dose inhalers in an in vitro infant ventilator lung model
    • Avent ML, Gal P, Ransom JL, et al: Evaluating the delivery of nebulized and metered-dose inhalers in an in vitro infant ventilator lung model. Ann Pharmacother 1999; 33: 144-148
    • (1999) Ann Pharmacother , vol.33 , pp. 144-148
    • Avent, M.L.1    Gal, P.2    Ransom, J.L.3
  • 20
    • 0022611208 scopus 로고
    • Aerosol delivery to the rabbit lung with an infant ventilator
    • Flavin M, MacDonald M, Dolovich M, et al: Aerosol delivery to the rabbit lung with an infant ventilator. Pediatr Pulmonol 1986; 2:35-39
    • (1986) Pediatr Pulmonol , vol.2 , pp. 35-39
    • Flavin, M.1    MacDonald, M.2    Dolovich, M.3
  • 21
    • 0026057654 scopus 로고
    • Aerosol delivery in neonatal ventilator circuits: A rabbit lung model
    • Cameron D, Arnot R, Clay M, et al: Aerosol delivery in neonatal ventilator circuits: A rabbit lung model. Pediatr Pulmonol 1991; 10:208-213
    • (1991) Pediatr Pulmonol , vol.10 , pp. 208-213
    • Cameron, D.1    Arnot, R.2    Clay, M.3
  • 22
    • 32744473313 scopus 로고    scopus 로고
    • Physicochemical aspects of nebulization: Comparison of five models of jet nebulizers
    • Di Paolo ER, Cotting J, Pannatier A: Physicochemical aspects of nebulization: Comparison of five models of jet nebulizers. Eur Hosp Pharm 2000; 6:83-87
    • (2000) Eur Hosp Pharm , vol.6 , pp. 83-87
    • Di Paolo, E.R.1    Cotting, J.2    Pannatier, A.3
  • 23
    • 0030916624 scopus 로고    scopus 로고
    • The science of nebulised drug delivery
    • O'Callaghan C, Barry PW: The science of nebulised drug delivery. Thorax 1997; 52(Suppl 2):S31-S44
    • (1997) Thorax , vol.52 , Issue.SUPPL. 2
    • O'Callaghan, C.1    Barry, P.W.2
  • 24
    • 0027328528 scopus 로고
    • Choice of mechanical ventilator: Influence on nebulizer performance
    • McPeck M, O'Riordan TG, Smaldone GC: Choice of mechanical ventilator: Influence on nebulizer performance. Respir Care 1993; 38:887-895
    • (1993) Respir Care , vol.38 , pp. 887-895
    • McPeck, M.1    O'Riordan, T.G.2    Smaldone, G.C.3
  • 25
    • 85030801193 scopus 로고    scopus 로고
    • Acutronic Medical System, Hirzel, Switzerland
    • Florian Reference Manual, Acutronic Medical System, Hirzel, Switzerland
    • Florian Reference Manual
  • 26
    • 0034780524 scopus 로고    scopus 로고
    • Reliable tidal volume estimates at the airway opening with an infant monitor during high-frequency oscillatory ventilation
    • Scalfaro P, Pillow JJ, Sly PD, et al: Reliable tidal volume estimates at the airway opening with an infant monitor during high-frequency oscillatory ventilation. Crit Care Med 2001; 29:1925-1930
    • (2001) Crit Care Med , vol.29 , pp. 1925-1930
    • Scalfaro, P.1    Pillow, J.J.2    Sly, P.D.3
  • 29
    • 0035008993 scopus 로고    scopus 로고
    • Validation of laser diffraction method as a substitute for cascade impaction in the European project for a nebulizer standard
    • Vecellio None L, Grimbert D, Becquemin MH, et al: Validation of laser diffraction method as a substitute for cascade impaction in the European project for a nebulizer standard. J Aerosol Med 2001; 14:107-114
    • (2001) J Aerosol Med , vol.14 , pp. 107-114
    • Vecellio None, L.1    Grimbert, D.2    Becquemin, M.H.3
  • 30
    • 32744457493 scopus 로고
    • Respiratory therapy equipment - Jet nebulizers and jet nebulizer air pump
    • Australian/New Zealand Standard. Respiratory therapy equipment-Jet nebulizers and jet nebulizer air pump. AS/NZS 1994; 4236
    • (1994) AS/NZS , pp. 4236
  • 32
    • 0029775579 scopus 로고    scopus 로고
    • Aerosol delivery from a metered-dose inhaler during mechanical ventilation: An in vitro model
    • Fink JB, Dhand R, Duarte AG, et al: Aerosol delivery from a metered-dose inhaler during mechanical ventilation: An in vitro model. Am J Respir Crit Care Med 1996; 154: 382-387
    • (1996) Am J Respir Crit Care Med , vol.154 , pp. 382-387
    • Fink, J.B.1    Dhand, R.2    Duarte, A.G.3
  • 33
    • 0031983971 scopus 로고    scopus 로고
    • Salbutamol delivery from a hydrofuoroalkane pressurized metered-dose inhaler in pediatric ventilator circuits, an in vitro study
    • Wildhaber JH, Hayden MJ, Dore ND, et al: Salbutamol delivery from a hydrofuoroalkane pressurized metered-dose inhaler in pediatric ventilator circuits, an in vitro study. Chest 1998; 113:186-191
    • (1998) Chest , vol.113 , pp. 186-191
    • Wildhaber, J.H.1    Hayden, M.J.2    Dore, N.D.3
  • 34
    • 0028630804 scopus 로고
    • Why do medical nebulizers differ in their output and particle size characteristics?
    • Nerbrinck O, Dahlbäck M, Hansson HC: Why do medical nebulizers differ in their output and particle size characteristics? J Aerosol Med 1994; 7:259-276
    • (1994) J Aerosol Med , vol.7 , pp. 259-276
    • Nerbrinck, O.1    Dahlbäck, M.2    Hansson, H.C.3
  • 35
    • 0026728835 scopus 로고
    • Delivery of a nebulized aerosol to a lung model during mechanical ventilation: Effect of ventilator settings and nebulizer type, position, and volume of fill
    • O'Doherty, Thomas SHL, Page CJ, et al: Delivery of a nebulized aerosol to a lung model during mechanical ventilation: Effect of ventilator settings and nebulizer type, position, and volume of fill. Am Rev Respir Dis 1992; 146:383-388
    • (1992) Am Rev Respir Dis , vol.146 , pp. 383-388
    • O'Doherty1    Thomas, S.H.L.2    Page, C.J.3
  • 36
    • 0032900977 scopus 로고    scopus 로고
    • Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors
    • Fink JB, Dhand R, Grychowsky J, et al: Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors. Am J Respir Crit Care Med 1999; 159:63-68
    • (1999) Am J Respir Crit Care Med , vol.159 , pp. 63-68
    • Fink, J.B.1    Dhand, R.2    Grychowsky, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.