메뉴 건너뛰기




Volumn 23, Issue 4, 2005, Pages 713-719

Magnetic resonance imaging in the evaluation of periprosthetic acetabular osteolysis: A cadaveric study

Author keywords

Cadaver; Hip; MRI; Osteolysis; Radiographs

Indexed keywords

ACETABULUM; ARTICLE; BONE LESION; BONE RADIOGRAPHY; CADAVER; CLINICAL PROTOCOL; CORRELATION FUNCTION; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; DIAGNOSTIC VALUE; DISEASE SIMULATION; HUMAN; HUMAN TISSUE; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOLYSIS; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RADIODIAGNOSIS; SENSITIVITY AND SPECIFICITY; STATISTICAL SIGNIFICANCE; TOTAL HIP PROSTHESIS;

EID: 21844461824     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.orthres.2005.02.007     Document Type: Article
Times cited : (60)

References (29)
  • 2
    • 0030665067 scopus 로고    scopus 로고
    • Primary cementless acetabular reconstruction in patients younger than 50 years old. 7- to 11-year results
    • R.A. Berger J.J. Jacobs L.R. Quigley A.G. Rosenberg J.O. Galante Primary cementless acetabular reconstruction in patients younger than 50 years old. 7- to 11-year results Clin Orthop 1997 216-226
    • (1997) Clin. Orthop. , pp. 216-226
    • Berger, R.A.1    Jacobs, J.J.2    Quigley, L.R.3    Rosenberg, A.G.4    Galante, J.O.5
  • 3
    • 0028197478 scopus 로고
    • Severe polyethylene wear in total hip arthroplasty. Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner
    • J.V. Bono L. Sanford J.T. Toussaint Severe polyethylene wear in total hip arthroplasty. Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner J Arthroplasty 9 1994 119-125
    • (1994) J. Arthroplasty , vol.9 , pp. 119-125
    • Bono, J.V.1    Sanford, L.2    Toussaint, J.T.3
  • 4
    • 0035143772 scopus 로고    scopus 로고
    • Reliability of acetabular bone defect classification systems in revision total hip arthroplasty
    • D.G. Campbell D.S. Garbuz B.A. Masri C.P. Duncan Reliability of acetabular bone defect classification systems in revision total hip arthroplasty J Arthroplasty 16 2001 83-86
    • (2001) J. Arthroplasty , vol.16 , pp. 83-86
    • Campbell, D.G.1    Garbuz, D.S.2    Masri, B.A.3    Duncan, C.P.4
  • 5
    • 0021248046 scopus 로고
    • Radiographic versus clinical loosening of the acetabular component in noninfected total hip arthroplasty
    • A.S. Carlsson C.F. Gentz Radiographic versus clinical loosening of the acetabular component in noninfected total hip arthroplasty Clin Orthop 1984 145-150
    • (1984) Clin Orthop , pp. 145-150
    • Carlsson, A.S.1    Gentz, C.F.2
  • 8
    • 0028798063 scopus 로고
    • The problem is osteolysis
    • W.H. Harris The problem is osteolysis Clin Orthop 1995 46-53
    • (1995) Clin. Orthop. , pp. 46-53
    • Harris, W.H.1
  • 9
    • 0029838003 scopus 로고    scopus 로고
    • Relationship between polyethylene wear, pelvic osteolysis, and clinical symptomatology in patients with cementless acetabular components. A framework for decision making
    • W.J. Hozack J.J. Mesa C. Carey R.H. Rothman Relationship between polyethylene wear, pelvic osteolysis, and clinical symptomatology in patients with cementless acetabular components. A framework for decision making J Arthroplasty 11 1996 769-772
    • (1996) J. Arthroplasty , vol.11 , pp. 769-772
    • Hozack, W.J.1    Mesa, J.J.2    Carey, C.3    Rothman, R.H.4
  • 11
    • 0031947536 scopus 로고    scopus 로고
    • Cost-effectiveness of early surgical intervention in silent osteolysis
    • C.J. Lavernia Cost-effectiveness of early surgical intervention in silent osteolysis J Arthroplasty 13 1998 277-279
    • (1998) J. Arthroplasty , vol.13 , pp. 277-279
    • Lavernia, C.J.1
  • 12
    • 18244383316 scopus 로고    scopus 로고
    • Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear
    • R.J. Looney A. Boyd S. Totterman G.S. Seo J. Tamez-Pena D. Campbell et al.Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear Arthritis Res 4 2002 59-63
    • (2002) Arthritis Res. , vol.4 , pp. 59-63
    • Looney, R.J.1    Boyd, A.2    Totterman, S.3    Seo, G.S.4    Tamez-Pena, J.5    Campbell, D.6
  • 13
    • 0037264196 scopus 로고    scopus 로고
    • Rates and outcomes of primary and revision total hip replacement in the United States medicare population
    • N.N. Mahomed J.A. Barrett J.N. Katz C.B. Phillips E. Losina R.A. Lew et al. Rates and outcomes of primary and revision total hip replacement in the United States medicare population J Bone Joint Surg Am 85-A 2003 27-32
    • (2003) J. Bone Joint Surg. Am. , vol.85 A , pp. 27-32
    • Mahomed, N.N.1    Barrett, J.A.2    Katz, J.N.3    Phillips, C.B.4    Losina, E.5    Lew, R.A.6
  • 14
    • 0027786926 scopus 로고
    • Severe osteolysis of the pelvic in association with acetabular replacement without cement
    • W.J. Maloney P. Peters C.A. Engh H. Chandler Severe osteolysis of the pelvic in association with acetabular replacement without cement J Bone Joint Surg Am 75 1993 1627-1635
    • (1993) J. Bone Joint Surg. Am. , vol.75 , pp. 1627-1635
    • Maloney, W.J.1    Peters, P.2    Engh, C.A.3    Chandler, H.4
  • 17
    • 0036528661 scopus 로고    scopus 로고
    • Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty
    • L. Puri R.L. Wixson S.H. Stern J. Kohli R.W. Hendrix S.D. Stulberg Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty J Bone Joint Surg Am 84-A 2002 609-614
    • (2002) J. Bone Joint Surg. Am. , vol.84 A , pp. 609-614
    • Puri, L.1    Wixson, R.L.2    Stern, S.H.3    Kohli, J.4    Hendrix, R.W.5    Stulberg, S.D.6
  • 19
    • 0031857971 scopus 로고    scopus 로고
    • Preoperative description of severe acetabular defects caused by failed total hip replacement
    • D.D. Robertson C.J. Sutherland T. Lopes J. Yuan Preoperative description of severe acetabular defects caused by failed total hip replacement J Comput Assist Tomogr 22 1998 444-449
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 444-449
    • Robertson, D.D.1    Sutherland, C.J.2    Lopes, T.3    Yuan, J.4
  • 20
    • 0023866456 scopus 로고
    • Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants
    • D.D. Robertson P.J. Weiss E.K. Fishman D. Magid P.S. Walker Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants J Comput Assist Tomogr 12 1988 236-241
    • (1988) J Comput Assist Tomogr , vol.12 , pp. 236-241
    • Robertson, D.D.1    Weiss, P.J.2    Fishman, E.K.3    Magid, D.4    Walker, P.S.5
  • 21
    • 0034925209 scopus 로고    scopus 로고
    • Reliability and intraoperative validity of preoperative assessment of standardized plain radiographs in predicting bone loss at revision hip surgery
    • K.J. Saleh J. Holtzman A. Gafni L. Saleh A. Davis S. Resig et al. Reliability and intraoperative validity of preoperative assessment of standardized plain radiographs in predicting bone loss at revision hip surgery J Bone Joint Surg Am 83-A 2001 1040-1046
    • (2001) J. Bone Joint Surg. Am. , vol.83 A , pp. 1040-1046
    • Saleh, K.J.1    Holtzman, J.2    Gafni, A.3    Saleh, L.4    Davis, A.5    Resig, S.6
  • 22
    • 0028198810 scopus 로고
    • The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis
    • T.P. Schmalzried D. Guttmann M. Grecula H.C. Amstutz The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis J Bone Joint Surg Am 76 1994 677-688
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 677-688
    • Schmalzried, T.P.1    Guttmann, D.2    Grecula, M.3    Amstutz, H.C.4
  • 24
    • 0036396638 scopus 로고    scopus 로고
    • Monitoring pelvic osteolysis following total hip replacement surgery: An algorithm for surveillance
    • S.D. Stulberg R.L. Wixson A.D. Adams R.W. Hendrix J.B. Bernfield Monitoring pelvic osteolysis following total hip replacement surgery: An algorithm for surveillance J Bone Joint Surg Am 84-A 2 2002 116-122
    • (2002) J Bone Joint Surg Am , vol.84 A , Issue.2 , pp. 116-122
    • Stulberg, S.D.1    Wixson, R.L.2    Adams, A.D.3    Hendrix, R.W.4    Bernfield, J.B.5
  • 25
    • 0023939169 scopus 로고
    • Radiographic evaluation of acetabular bone stock in failed total hip arthroplasty
    • C.J. Sutherland Radiographic evaluation of acetabular bone stock in failed total hip arthroplasty J Arthroplasty 3 1988 73-79
    • (1988) J. Arthroplasty , vol.3 , pp. 73-79
    • Sutherland, C.J.1
  • 28
    • 0028956936 scopus 로고
    • Patterns of osteolysis around total hip components inserted with and without cement
    • B. Zicat C.A. Engh E. Gokcen Patterns of osteolysis around total hip components inserted with and without cement J Bone Joint Surg Am 77 1995 432-439
    • (1995) J. Bone Joint Surg. Am. , vol.77 , pp. 432-439
    • Zicat, B.1    Engh, C.A.2    Gokcen, E.3
  • 29
    • 0033817898 scopus 로고    scopus 로고
    • Underestimation of pelvic osteolysis: The value of the iliac oblique radiograph
    • R.H. Zimlich T.K. Fehring Underestimation of pelvic osteolysis: The value of the iliac oblique radiograph J Arthroplasty 15 2000 796-801
    • (2000) J. Arthroplasty , vol.15 , pp. 796-801
    • Zimlich, R.H.1    Fehring, T.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.