메뉴 건너뛰기




Volumn 22, Issue 3, 1998, Pages 444-449

Preoperative description of severe acetabular defects caused by failed total hip replacement

Author keywords

Acetabulum; Arthroplasty; Bones, abnormalities; Computed tomography; Hip; Modeling, three dimensional; Pelvis, defects; Surgical planning

Indexed keywords

BONE; COMPUTERIZED TOMOGRAPHY; DEFECTS; GRADING; HIP PROSTHESES; ORTHOPEDICS; RADIOGRAPHY; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 0031857971     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004728-199805000-00018     Document Type: Article
Times cited : (30)

References (17)
  • 2
    • 0025099128 scopus 로고
    • Salvage total hip reconstruction in patients with major acetabular bone deficiency using structural femoral head allograft
    • Jasty M, Harris W. Salvage total hip reconstruction in patients with major acetabular bone deficiency using structural femoral head allograft. J Bone Joint Surg [Br] 1990;72:63-7.
    • (1990) J Bone Joint Surg [Br] , vol.72 , pp. 63-67
    • Jasty, M.1    Harris, W.2
  • 3
    • 0026664833 scopus 로고
    • The fate of massive allografts in total acetabular revision
    • Pollock FH, Whiteside LA. The fate of massive allografts in total acetabular revision. J Arthroplasty 1992;7:271-6.
    • (1992) J Arthroplasty , vol.7 , pp. 271-276
    • Pollock, F.H.1    Whiteside, L.A.2
  • 4
    • 0027272895 scopus 로고
    • High failure rate of bulk femoral head allograft in total hip acetabular reconstructions at 10 years
    • Kwong LM, Jasty M, Harris WH. High failure rate of bulk femoral head allograft in total hip acetabular reconstructions at 10 years. J Arthroplasty 1993;8:341-6.
    • (1993) J Arthroplasty , vol.8 , pp. 341-346
    • Kwong, L.M.1    Jasty, M.2    Harris, W.H.3
  • 5
    • 0027313220 scopus 로고
    • Revision total hip arthroplasty: The use of solid allograft
    • Zmolek JC, Dorr LD. Revision total hip arthroplasty: the use of solid allograft. J Arthroplasty 1993;8:361-70.
    • (1993) J Arthroplasty , vol.8 , pp. 361-370
    • Zmolek, J.C.1    Dorr, L.D.2
  • 6
    • 0028274572 scopus 로고
    • Failure of structural acetabular allografts in cementless revision hip arthroplasty
    • Hooten JP, Engh C, Engh C. Failure of structural acetabular allografts in cementless revision hip arthroplasty. J Bone Joint Surg [Br] 1994;76:419-22.
    • (1994) J Bone Joint Surg [Br] , vol.76 , pp. 419-422
    • Hooten, J.P.1    Engh, C.2    Engh, C.3
  • 7
    • 84889186481 scopus 로고
    • Interobserver variability in the assessment of acetabular deficiencies with plain radiograph
    • Hauser D, Wenz J, Fishman E, Robertson D, Scott W, Brooker A. Interobserver variability in the assessment of acetabular deficiencies with plain radiograph. Radiology 1993;189:151.
    • (1993) Radiology , vol.189 , pp. 151
    • Hauser, D.1    Wenz, J.2    Fishman, E.3    Robertson, D.4    Scott, W.5    Brooker, A.6
  • 8
    • 0027236336 scopus 로고
    • Bone-grafting for acetabular deficiency during primary and revision total hip arthroplasty
    • Knight JL, Fujii K, Atwater R, Grothaus L. Bone-grafting for acetabular deficiency during primary and revision total hip arthroplasty. J Arthroplasty 1993;8:371-82.
    • (1993) J Arthroplasty , vol.8 , pp. 371-382
    • Knight, J.L.1    Fujii, K.2    Atwater, R.3    Grothaus, L.4
  • 9
    • 0029119822 scopus 로고
    • Use of acetabular models in planning complex acetabular reconstructions
    • John JF, Talbert RE, Taylor JK, Bargar WL. Use of acetabular models in planning complex acetabular reconstructions. J Arthroplasty 1995;10:661-6.
    • (1995) J Arthroplasty , vol.10 , pp. 661-666
    • John, J.F.1    Talbert, R.E.2    Taylor, J.K.3    Bargar, W.L.4
  • 10
    • 0026442215 scopus 로고
    • Measurement of acetabular component migration using two-dimensional radiography
    • Sutherland CJ, Bresina SJ. Measurement of acetabular component migration using two-dimensional radiography. J Arthroplasty 1992;7(suppl):377-9.
    • (1992) J Arthroplasty , vol.7 , Issue.SUPPL. , pp. 377-379
    • Sutherland, C.J.1    Bresina, S.J.2
  • 11
    • 0030068106 scopus 로고    scopus 로고
    • Treatment of Type III acetabular deficiencies in revision total hip arthroplasty without structural bone-graft
    • Sutherland CJ. Treatment of Type III acetabular deficiencies in revision total hip arthroplasty without structural bone-graft. J Arthroplasty 1996;11:91-8.
    • (1996) J Arthroplasty , vol.11 , pp. 91-98
    • Sutherland, C.J.1
  • 12
    • 0024368926 scopus 로고
    • Classification and management of acetabular abnormalities in total hip arthroplasty
    • D'Antonio JA, Capello WN, Borden LS, et al. Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop 1989;243:126-37.
    • (1989) Clin Orthop , vol.243 , pp. 126-137
    • D'Antonio, J.A.1    Capello, W.N.2    Borden, L.S.3
  • 13
    • 0028155886 scopus 로고
    • Acetabular defect classification and surgical reconstruction in revision arthroplasty: A 6-year follow-up evaluation
    • Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty: a 6-year follow-up evaluation. J Arthroplasty 1994;9:33-43.
    • (1994) J Arthroplasty , vol.9 , pp. 33-43
    • Paprosky, W.G.1    Perona, P.G.2    Lawrence, J.M.3
  • 15
    • 0342432871 scopus 로고
    • Fast routine for reduction of artifacts caused by metallic implants in CT images
    • Kalender WA, Hebel R. Fast routine for reduction of artifacts caused by metallic implants in CT images Radiology 1986;161: 576-7.
    • (1986) Radiology , vol.161 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2
  • 16
    • 0023866456 scopus 로고
    • Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants
    • Robertson DD, Weiss PJ, Fishman EK, Magid D, Walker PS. Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants. J Comput Assist Tomogr 1988;12: 236-41.
    • (1988) J Comput Assist Tomogr , vol.12 , pp. 236-241
    • Robertson, D.D.1    Weiss, P.J.2    Fishman, E.K.3    Magid, D.4    Walker, P.S.5
  • 17
    • 0030983762 scopus 로고    scopus 로고
    • Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction
    • Robertson DD, Yuan J, Wang G, Vannier M. Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. J Comput Assist Tomogr 1997;21:293-8.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 293-298
    • Robertson, D.D.1    Yuan, J.2    Wang, G.3    Vannier, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.