메뉴 건너뛰기




Volumn 3, Issue , 2004, Pages 1976-1979

NSPUDT structures with inclined reflectors on langasite

Author keywords

Langasite; NSPUDT; Reflection; SAW

Indexed keywords

LANGASITE; NATURAL SINGLE PHASE UNIDIRECTIONAL TRANSDUCERS (NSPUDT); REFLECTING ARRAYS; SURFACE ACOUSTIC WAVES (SAW);

EID: 21644444791     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2004.1418220     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 1
    • 0022313948 scopus 로고
    • The natural single-phase unidirectional transducer: A new low-loss SAW transducer
    • P. V. Wright, "The Natural Single-Phase Unidirectional Transducer: A New Low-Loss SAW Transducer," Proc. IEEE Ultrason. Symp., 1985. pp. 58-63.
    • (1985) Proc. IEEE Ultrason. Symp. , pp. 58-63
    • Wright, P.V.1
  • 2
    • 0027744861 scopus 로고
    • A low-loss SAW filter using two finger per wavelength electrodes on the NSPUDT orientation of quartz
    • C. S. Lam and D. Gunes, "A Low-Loss SAW Filter Using Two Finger Per Wavelength Electrodes on the NSPUDT Orientation of Quartz," Proc. IEEE Ultrason. Symp., 1993, pp. 185-188.
    • (1993) Proc. IEEE Ultrason. Symp. , pp. 185-188
    • Lam, C.S.1    Gunes, D.2
  • 3
    • 0029515655 scopus 로고
    • Low-loss SAW filter using thickness difference type of IDT on the NSPUDT orientation substrate
    • K. Yamanouchi, M. Takeuchi, H. Odagawa, and M. Tanaka, "Low-Loss SAW Filter Using Thickness Difference Type of IDT on the NSPUDT Orientation Substrate," Proc. IEEE Frequency Control Symp., 1995, pp. 537-541.
    • (1995) Proc. IEEE Frequency Control Symp. , pp. 537-541
    • Yamanouchi, K.1    Takeuchi, M.2    Odagawa, H.3    Tanaka, M.4
  • 4
    • 0029463435 scopus 로고
    • SAW transducer configurations for reversing the directivity of NSPUDT substrates
    • M. Takeuchi, H. Odagawa, M. Tanaka, and K.Yamanouchi, "SAW Transducer Configurations for Reversing the Directivity of NSPUDT Substrates," Proc. IEEE Ultrason. Symp., 1995, pp. 17-22.
    • (1995) Proc. IEEE Ultrason. Symp. , pp. 17-22
    • Takeuchi, M.1    Odagawa, H.2    Tanaka, M.3    Yamanouchi, K.4
  • 6
    • 0033295205 scopus 로고    scopus 로고
    • Optimal cut of langasite for high performance SAW devices
    • N. F. Naumenko and L. P. Solie, "Optimal Cut of Langasite for High Performance SAW Devices," Proc. IEEE Ultrason. Symp., 1999, pp. 243-248.
    • (1999) Proc. IEEE Ultrason. Symp. , pp. 243-248
    • Naumenko, N.F.1    Solie, L.P.2
  • 8
    • 0036995311 scopus 로고    scopus 로고
    • Nondestructive investigation of 4-inch langasite wafer acoustic homogeneity
    • S. A. Sakharov et al., "Nondestructive Investigation of 4-inch Langasite Wafer Acoustic Homogeneity." Proc. IEEE Ultrason. Symp., 2002, pp. 218-221.
    • (2002) Proc. IEEE Ultrason. Symp. , pp. 218-221
    • Sakharov, S.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.