메뉴 건너뛰기




Volumn 1, Issue , 2004, Pages 37-44

Frost temperature relations for defrosting sensing system

Author keywords

[No Author keywords available]

Indexed keywords

ATMOSPHERIC HUMIDITY; CONCENTRATION (PROCESS); CONTROL SYSTEMS; HEAT FLUX; HOLOGRAPHIC INTERFEROMETRY; MELTING; REFRIGERATION; REYNOLDS NUMBER; SIGNAL PROCESSING; THERMOMETERS;

EID: 21544465061     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1115/ht-fed2004-56074     Document Type: Conference Paper
Times cited : (4)

References (9)
  • 3
    • 0034462576 scopus 로고    scopus 로고
    • Modeling frost characteristics on heat exchanger fins: Part I. Numerical model
    • PA, 2000, 2000 Annual Meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineering, INC, Jun 25-Jun 28 2000, Minneapolis, MM, USA
    • Chen Hong, Thomas Leena, Besant Robert W., 2000, Modeling frost characteristics on heat exchanger fins: Part I. Numerical model, ASHRAE Transactions, v106 (PA, 2000, 2000 Annual Meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineering, INC, Jun 25-Jun 28 2000, Minneapolis, MM, USA, p 357-367
    • (2000) ASHRAE Transactions , vol.106 , pp. 357-367
    • Hong, C.1    Thomas, L.2    Besant Robert, W.3
  • 4
    • 0034460834 scopus 로고    scopus 로고
    • Modeling frost characteristics on heat exchanger fins: Part II. Model validation and limitations
    • PA, 2000, 2000 Annual Meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineering, INC, Jun 25-Jun 28 2000, Minneapolis, MN, USA
    • Chen Hong, Thomas Leena, and Besant Robert W, 2000, Modeling frost characteristics on heat exchanger fins: Part II. Model validation and limitations, ASHRAE Transactions, v106 (PA, 2000, 2000 Annual Meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineering, INC, Jun 25-Jun 28 2000, Minneapolis, MN, USA, p 368-376
    • (2000) ASHRAE Transactions , vol.106 , pp. 368-376
    • Hong, C.1    Thomas, L.2    Besant Robert, W.3
  • 5
    • 0032650794 scopus 로고    scopus 로고
    • Effects of evaporator frosting on the performance of a air-to-air heat pump
    • March 1999
    • Martinez-Frias J., Aceves S.M., 1999, Effects of evaporator frosting on the performance of a air-to-air heat pump, ASME Transactions, v121, March 1999, p 60-65
    • (1999) ASME Transactions , vol.121 , pp. 60-65
    • Martinez-Frias, J.1    Aceves, S.M.2
  • 6
    • 18744380333 scopus 로고    scopus 로고
    • Fan supplied heat exchanger fin performance under frosting conditions
    • Chen Hong, Thomas Leena, Besant Robert W., 2002, Fan supplied heat exchanger fin performance under frosting conditions, Int. Journal of Refrigeration, v26, p 140-149
    • (2002) Int. Journal of Refrigeration , vol.26 , pp. 140-149
    • Hong, C.1    Thomas, L.2    Besant Robert, W.3
  • 7
    • 0036459601 scopus 로고    scopus 로고
    • Frost deposition and refrigerant distribution in microchannel heat exchangers
    • June 2002
    • Song S., Bullard C.W., Hmjak P.S., 2002, Frost deposition and refrigerant distribution in microchannel heat exchangers, ASHRAE Transactions, v108 PART 2, June 2002, p 944-953
    • (2002) ASHRAE Transactions , vol.108 , Issue.2 PART , pp. 944-953
    • Song, S.1    Bullard, C.W.2    Hmjak, P.S.3
  • 8
    • 0036455361 scopus 로고    scopus 로고
    • Frost performance of a three-row fin staged heat pump evaporator, 2002
    • June
    • Watters R.J., O'Neal D.L., Yang J., Frost performance of a three-row fin staged heat pump evaporator, 2002, ASHRAE Transactions, v108 PART 2, June 2002, p 318-329
    • (2002) ASHRAE Transactions , vol.108 , Issue.2 PART , pp. 318-329
    • Watters, R.J.1    O'Neal, D.L.2    Yang, J.3
  • 9
    • 0025796005 scopus 로고
    • Fiber-optic ice sensors fro refrigerators
    • Paone N., Rossi G., Fiber-optic ice sensors fro refrigerators, SPIE proceedings, 1991, p 129-139
    • (1991) SPIE Proceedings , pp. 129-139
    • Paone, N.1    Rossi, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.