메뉴 건너뛰기




Volumn 28, Issue 10, 2004, Pages 940-944

Development of an implantable undulation type ventricular assist device for control of organ circulation

Author keywords

Laser doppler flowmeter; Multiple organ failure; Organ circulation; Undulation pump; Ventricular assist device

Indexed keywords

BLOOD; BLOOD PRESSURE; FIBER OPTIC SENSORS; HEMODYNAMICS; LEFT VENTRICULAR ASSIST DEVICES; PUMPING (LASER);

EID: 20144376606     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2004.07382.x     Document Type: Conference Paper
Times cited : (6)

References (20)
  • 1
    • 0030036571 scopus 로고    scopus 로고
    • Can we develop a nonpulsatile permanent rotary blood pump? Yes, we can
    • Nosé Y, Kawahito K, Nakazawa T. Can we develop a nonpulsatile permanent rotary blood pump? Yes, we can. Artif Organs 1996;20:467-74.
    • (1996) Artif Organs , vol.20 , pp. 467-474
    • Nosé, Y.1    Kawahito, K.2    Nakazawa, T.3
  • 2
    • 0028353650 scopus 로고
    • Technical requirements and limitations of miniaturized axial flow pumps for circulatory support
    • Reul H. Technical requirements and limitations of miniaturized axial flow pumps for circulatory support. Cardiology 1994;84:187-93.
    • (1994) Cardiology , vol.84 , pp. 187-193
    • Reul, H.1
  • 4
    • 0025458341 scopus 로고
    • Another way of pumping blood with a rotary but noncentrifugal pump for an artificial heart
    • Monties JR, Mesana T, Havlik P, Trinkl J, Demunck JL, Candelon B. Another way of pumping blood with a rotary but noncentrifugal pump for an artificial heart. ASAIO J 1990;36:M258-60.
    • (1990) ASAIO J , vol.36
    • Monties, J.R.1    Mesana, T.2    Havlik, P.3    Trinkl, J.4    Demunck, J.L.5    Candelon, B.6
  • 5
    • 0036798185 scopus 로고    scopus 로고
    • End-organ function during chronic nonpulsatile circulation
    • Saito S, Westaby S, Piggot D, et al. End-organ function during chronic nonpulsatile circulation. Ann Thorac Surg 2002; 74:1080-5.
    • (2002) Ann Thorac Surg , vol.74 , pp. 1080-1085
    • Saito, S.1    Westaby, S.2    Piggot, D.3
  • 6
    • 0033839775 scopus 로고    scopus 로고
    • Continuously maintaining positive flow avoids endocardial suction of a rotary blood pump with left ventricular bypass
    • Akimoto T, Yamazaki K, Litwak P, et al. Continuously maintaining positive flow avoids endocardial suction of a rotary blood pump with left ventricular bypass. Artif Organs 2000; 24:606-10.
    • (2000) Artif Organs , vol.24 , pp. 606-610
    • Akimoto, T.1    Yamazaki, K.2    Litwak, P.3
  • 7
    • 0031238971 scopus 로고    scopus 로고
    • The cool seal system: A practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps
    • Yamazaki K, Mori T, Tomioka J, et al. The cool seal system: a practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps. ASAIO J 1997;43:M567-71.
    • (1997) ASAIO J , vol.43
    • Yamazaki, K.1    Mori, T.2    Tomioka, J.3
  • 8
    • 0031943306 scopus 로고    scopus 로고
    • Study of left ventricular bypass using Wankel type semipulsatile blood pump
    • Mitsui N, Fukunaga S, Sueda T, et al. Study of left ventricular bypass using Wankel type semipulsatile blood pump. Artif Organs 1998;22:419-25.
    • (1998) Artif Organs , vol.22 , pp. 419-425
    • Mitsui, N.1    Fukunaga, S.2    Sueda, T.3
  • 10
    • 0037542599 scopus 로고    scopus 로고
    • Advance in animal experiments with the undulation pump total artificial heart: 50 and 54 day survival periods with 1/R control
    • Abe Y, Chinzei T, Isoyama T, et al. Advance in animal experiments with the undulation pump total artificial heart: 50 and 54 day survival periods with 1/R control. ASAIO J 2003;49: 325-32.
    • (2003) ASAIO J , vol.49 , pp. 325-332
    • Abe, Y.1    Chinzei, T.2    Isoyama, T.3
  • 11
    • 0036865567 scopus 로고    scopus 로고
    • Non-linear dynamic analysis of hemodynamic parameters in an undulation type artificial heart system
    • Yambe T, Abe Y, Isoyama T, et al. Non-linear dynamic analysis of hemodynamic parameters in an undulation type artificial heart system. Biomed Pharmacother 2002;56(Suppl 2):364s-6s.
    • (2002) Biomed Pharmacother , vol.56 , Issue.2 SUPPL.
    • Yambe, T.1    Abe, Y.2    Isoyama, T.3
  • 12
    • 0345701510 scopus 로고    scopus 로고
    • Development of an implantable high-energy and compact battery system for artificial heart
    • Okamoto E, Inoue T, Watanabe K, et al. Development of an implantable high-energy and compact battery system for artificial heart. Artif Organs 2003;27:184-8.
    • (2003) Artif Organs , vol.27 , pp. 184-188
    • Okamoto, E.1    Inoue, T.2    Watanabe, K.3
  • 13
    • 0026832844 scopus 로고
    • An automatic control algorithm for the optimal driving of the ventricular-assist device
    • Yoshizawa M, Takeda H, Watanabe T, et al. An automatic control algorithm for the optimal driving of the ventricular-assist device. IEEE Trans Biomed Eng 1992;39:243-52.
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 243-252
    • Yoshizawa, M.1    Takeda, H.2    Watanabe, T.3
  • 14
    • 0033012346 scopus 로고    scopus 로고
    • Vagal nerve activity recording in the awake condition for the control of an artificial heart system
    • Yambe T, Nanka S, Kobayashi S, et al. Vagal nerve activity recording in the awake condition for the control of an artificial heart system. Artif Organs 1999;23:529-31.
    • (1999) Artif Organs , vol.23 , pp. 529-531
    • Yambe, T.1    Nanka, S.2    Kobayashi, S.3
  • 15
    • 0019749830 scopus 로고
    • Energy transmission across intact skin for powering artificial internal organs
    • Sherman C, Clay W, Dasse K, Daly B. Energy transmission across intact skin for powering artificial internal organs. Trans Am Soc Artif Intern Organs 1981;27:137-41.
    • (1981) Trans Am Soc Artif Intern Organs , vol.27 , pp. 137-141
    • Sherman, C.1    Clay, W.2    Dasse, K.3    Daly, B.4
  • 16
    • 0032816574 scopus 로고    scopus 로고
    • Peripheral vascular resistances during total left heart bypass with an oscillated blood flow
    • Yambe T, Kawano S, Nanka S, et al. Peripheral vascular resistances during total left heart bypass with an oscillated blood flow. Artif Organs 1999;23:747-50.
    • (1999) Artif Organs , vol.23 , pp. 747-750
    • Yambe, T.1    Kawano, S.2    Nanka, S.3
  • 17
    • 0042308534 scopus 로고    scopus 로고
    • Functions for detecting malposition of transcutaneous energy transmission coils
    • Ozeki T, Chinzei T, Abe Y, et al. Functions for detecting malposition of transcutaneous energy transmission coils. ASAIO J 2003;49:469-74.
    • (2003) ASAIO J , vol.49 , pp. 469-474
    • Ozeki, T.1    Chinzei, T.2    Abe, Y.3
  • 18
    • 15144339699 scopus 로고    scopus 로고
    • Left heart bypass using the oscillated blood flow with totally implantable vibrating flow pump
    • Yambe T, Owada N, Kobayashi S, et al. Left heart bypass using the oscillated blood flow with totally implantable vibrating flow pump. Artif Organs 1998;22:426-9.
    • (1998) Artif Organs , vol.22 , pp. 426-429
    • Yambe, T.1    Owada, N.2    Kobayashi, S.3
  • 19
    • 0028031761 scopus 로고
    • Totally implantable total artificial heart and ver tricular assist device with multipurpose miniature electromechanical energy system
    • Takatani S, Orime Y, Tasai K, et al. Totally implantable total artificial heart and ver tricular assist device with multipurpose miniature electromechanical energy system. Artif Organs 1994;18:80-92.
    • (1994) Artif Organs , vol.18 , pp. 80-92
    • Takatani, S.1    Orime, Y.2    Tasai, K.3
  • 20
    • 12244260746 scopus 로고    scopus 로고
    • Recent progress in artificial organ research at Tohoku University
    • Yambe T, Yoshizawa M, Tanaka A, et al. Recent progress in artificial organ research at Tohoku University. Artif Organs 2003;27:2-7.
    • (2003) Artif Organs , vol.27 , pp. 2-7
    • Yambe, T.1    Yoshizawa, M.2    Tanaka, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.