메뉴 건너뛰기




Volumn 13, Issue 1, 2005, Pages 59-69

Comparison between a 7 French 6 MM tip cryothermal catheter and a 9 French 8 MM tip cryothermal catheter for cryoablation treatment of common atrial flutter

Author keywords

Ablation; Arrhythmia; Atrial flutter; Catheter; Cryo; Recurrence

Indexed keywords

ADULT; AGED; ARTICLE; CATHETER ABLATION; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CRYOTHERAPY; FLUOROSCOPY; FOLLOW UP; HEART ATRIUM FLUTTER; HEART CONDUCTION; HEART ELECTROPHYSIOLOGY; HUMAN; INTERMETHOD COMPARISON; LOW TEMPERATURE; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; SURGICAL TECHNIQUE; SYMPTOM; TREATMENT OUTCOME;

EID: 20844432377     PISSN: 1383875X     EISSN: 15728595     Source Type: Journal    
DOI: 10.1007/s10840-005-0353-7     Document Type: Article
Times cited : (26)

References (18)
  • 1
    • 0025095887 scopus 로고
    • Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo
    • Langberg JJ, Lee MA, Chin MC, Rosenqvist M. Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo. Pacing Clin Electrophysiol 1990;13(10):1242-1248.
    • (1990) Pacing Clin Electrophysiol , vol.13 , Issue.10 , pp. 1242-1248
    • Langberg, J.J.1    Lee, M.A.2    Chin, M.C.3    Rosenqvist, M.4
  • 2
    • 0036162048 scopus 로고    scopus 로고
    • The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium
    • Chan RC, Johnson SB, Seward JB, Packer DL. The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium. Pacing Clin Electrophysiol 2002;25(1):4-13.
    • (2002) Pacing Clin Electrophysiol , vol.25 , Issue.1 , pp. 4-13
    • Chan, R.C.1    Johnson, S.B.2    Seward, J.B.3    Packer, D.L.4
  • 3
    • 1942516919 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- Or 10-mm electrode catheters and a high-output radiofrequency energy generator: Results of a multicenter safety and efficacy study
    • Feld G, Wharton M, Plumb V, Daoud E, Friehling T, Epstein L. Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- or 10-mm electrode catheters and a high-output radiofrequency energy generator: Results of a multicenter safety and efficacy study. J Am Coll Cardiol 2004;43(8):1466-1472.
    • (2004) J Am Coll Cardiol , vol.43 , Issue.8 , pp. 1466-1472
    • Feld, G.1    Wharton, M.2    Plumb, V.3    Daoud, E.4    Friehling, T.5    Epstein, L.6
  • 6
    • 13544253313 scopus 로고    scopus 로고
    • Safety and efficacy of catheter cryoablation for the treatment of atrial flutter: Acute and long term results
    • Montenero AS, Bruno N, Antonelli A, et al. Safety and efficacy of catheter cryoablation for the treatment of atrial flutter: Acute and long term results. Ital Heart J 2004;5(Suppl. 1):131S-137S.
    • (2004) Ital Heart J , vol.5 , Issue.1 SUPPL.
    • Montenero, A.S.1    Bruno, N.2    Antonelli, A.3
  • 10
    • 0034610437 scopus 로고    scopus 로고
    • Cryothermal ablation of the slow pathway for the elimination of atrioventricular nodal reentrant tachycardia
    • Skanes AC, Dubuc M, Klein GJ, Thibault B, Krahn AD, Yee R, Roy D, Guerra P, Talajic M. Cryothermal ablation of the slow pathway for the elimination of atrioventricular nodal reentrant tachycardia. Circulation 2000;102(23):2856- 2860.
    • (2000) Circulation , vol.102 , Issue.23 , pp. 2856-2860
    • Skanes, A.C.1    Dubuc, M.2    Klein, G.J.3    Thibault, B.4    Krahn, A.D.5    Yee, R.6    Roy, D.7    Guerra, P.8    Talajic, M.9
  • 11
    • 0036272811 scopus 로고    scopus 로고
    • Successful treatment of anteroseptal accessory pathways by transvenous cryomapping and cryoablation
    • Lanzotti ME, De Ponti R, Tritto M, Spadacini G, Salerno-Uriarte JA. Successful treatment of anteroseptal accessory pathways by transvenous cryomapping and cryoablation. Ital Heart J 2002;3(2):128-132.
    • (2002) Ital Heart J , vol.3 , Issue.2 , pp. 128-132
    • Lanzotti, M.E.1    De Ponti, R.2    Tritto, M.3    Spadacini, G.4    Salerno-Uriarte, J.A.5
  • 13
    • 13544276756 scopus 로고    scopus 로고
    • Safety and efficacy of a 7FR, 6 mm tip cryoablation catheter for the treatment of atrial flutter in 98 consecutive patients
    • Montenero AS, Bruno N, Zumbo F, et al. Safety and efficacy of a 7FR, 6 mm tip cryoablation catheter for the treatment of atrial flutter in 98 consecutive patients. Europace 2003;4(Suppl A):A4.
    • (2003) Europace , vol.4 , Issue.SUPPL. A
    • Montenero, A.S.1    Bruno, N.2    Zumbo, F.3
  • 14
    • 0037432308 scopus 로고    scopus 로고
    • Randomized study comparing radiofrequency ablation with cryoablation for the treatment of atrial flutter with emphasis on pain perception
    • Timmermans C, Ayers GM, Crijns HJ, Rodriguez LM. Randomized study comparing radiofrequency ablation with cryoablation for the treatment of atrial flutter with emphasis on pain perception. Circulation 2003;107(9):1250-1252.
    • (2003) Circulation , vol.107 , Issue.9 , pp. 1250-1252
    • Timmermans, C.1    Ayers, G.M.2    Crijns, H.J.3    Rodriguez, L.M.4
  • 15
    • 0036817370 scopus 로고    scopus 로고
    • Catheter-based cryoablation produces permanent bidirectional cavotricuspid isthmus conduction block in dogs
    • Timmermans C, Rodriguez LM, Van Suylen RJ, et al. Catheter-based cryoablation produces permanent bidirectional cavotricuspid isthmus conduction block in dogs. J Interv Card Electrophysiol 2002;7(2):149-155.
    • (2002) J Interv Card Electrophysiol , vol.7 , Issue.2 , pp. 149-155
    • Timmermans, C.1    Rodriguez, L.M.2    Van Suylen, R.J.3
  • 17
    • 0030045654 scopus 로고    scopus 로고
    • Electrophysiological effects of catheter ablation of inferior vena cavaricuspid annulus isthmus in common atrial flutter
    • Cauchemez B, Haissaguerre M, Fischer B, Thomas O, Clementy J, Coumel P. Electrophysiological effects of catheter ablation of inferior vena cavaricuspid annulus isthmus in common atrial flutter. Circulation 1996;93(2):284-294.
    • (1996) Circulation , vol.93 , Issue.2 , pp. 284-294
    • Cauchemez, B.1    Haissaguerre, M.2    Fischer, B.3    Thomas, O.4    Clementy, J.5    Coumel, P.6
  • 18
    • 0037250360 scopus 로고    scopus 로고
    • Catheter cryoablation of supraventricular arrhythmias: A painless alternative to radiofrequency energy
    • Lowe MD, Meara M, Mason J, Grace AA, Murgatroyd FD. Catheter cryoablation of supraventricular arrhythmias: A painless alternative to radiofrequency energy. Pacing Clin Electrophysiol 2003;26(1 Pt 2):500-503.
    • (2003) Pacing Clin Electrophysiol , vol.26 , Issue.1 PART 2 , pp. 500-503
    • Lowe, M.D.1    Meara, M.2    Mason, J.3    Grace, A.A.4    Murgatroyd, F.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.