메뉴 건너뛰기




Volumn 28, Issue 6, 2005, Pages 573-584

Development of implantable devices for continuous ambulatory monitoring of central hemodynamic values in heart failure patients

Author keywords

Hemodynamic monitoring; Implantable monitoring; Remote monitoring

Indexed keywords

ACCURACY; AMBULATORY MONITORING; CONGESTIVE HEART FAILURE; DIASTOLIC BLOOD PRESSURE; FEMALE; FOLLOW UP; HEALTH CARE; HEART FAILURE; HEART RIGHT VENTRICLE PRESSURE; HEMODYNAMIC MONITORING; HUMAN; IMPLANT; LONG TERM CARE; MAJOR CLINICAL STUDY; MALE; MONITOR; PATIENT CARE; PULMONARY ARTERY; RELIABILITY; REVIEW;

EID: 20544477576     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2005.09558.x     Document Type: Review
Times cited : (31)

References (37)
  • 1
    • 0032741125 scopus 로고    scopus 로고
    • Relationship between exertional symptoms and functional capacity in patients with heart failure
    • Wilson JR, Hanamanthu S, Chomsky DB, et al. Relationship between exertional symptoms and functional capacity in patients with heart failure. J Am Coll Cardiol 1999; 33:1943-1947.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1943-1947
    • Wilson, J.R.1    Hanamanthu, S.2    Chomsky, D.B.3
  • 2
    • 0024497513 scopus 로고
    • The limited reliability of physical signs for estimating hemodynamics in chronic heart failure
    • Stevenson LW, Perloff JK. The limited reliability of physical signs for estimating hemodynamics in chronic heart failure. JAMA 1989; 261:884-888.
    • (1989) JAMA , vol.261 , pp. 884-888
    • Stevenson, L.W.1    Perloff, J.K.2
  • 3
    • 0033495266 scopus 로고    scopus 로고
    • Tailored therapy to hemodynamic goals for advanced heart failure
    • Stevenson LW. Tailored therapy to hemodynamic goals for advanced heart failure. Eur J Heart Fail 1999; 1:251-257.
    • (1999) Eur J Heart Fail , vol.1 , pp. 251-257
    • Stevenson, L.W.1
  • 4
    • 0030744896 scopus 로고    scopus 로고
    • Sustained hemodynamic efficacy of therapy tailored to reduce filling pressures in survivors with advanced heart failure
    • Steimle AE, Stevenson LW, Chelimsky-Fallick C, et al. Sustained hemodynamic efficacy of therapy tailored to reduce filling pressures in survivors with advanced heart failure. Circulation 1997; 96:1165-1172.
    • (1997) Circulation , vol.96 , pp. 1165-1172
    • Steimle, A.E.1    Stevenson, L.W.2    Chelimsky-Fallick, C.3
  • 5
    • 0020600281 scopus 로고
    • Ambulatory monitoring of pulmonary artery pressure. A preliminary clinical evaluation
    • Nathan AW, Perry SG, Cochrane T, et al. Ambulatory monitoring of pulmonary artery pressure. A preliminary clinical evaluation. Br Heart J 1983; 49:33-37.
    • (1983) Br Heart J , vol.49 , pp. 33-37
    • Nathan, A.W.1    Perry, S.G.2    Cochrane, T.3
  • 6
    • 0025115320 scopus 로고
    • Pulmonary artery pressure changes during exercise and daily activities in chronic heart failure
    • Gibbs JSR, Keegan J, Wright C, et al. Pulmonary artery pressure changes during exercise and daily activities in chronic heart failure. J Am Coll Cardiol 1990; 15:51-61.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 51-61
    • Gibbs, J.S.R.1    Keegan, J.2    Wright, C.3
  • 7
    • 0030054292 scopus 로고    scopus 로고
    • Initial experience with an implantable hemodynamic monitor
    • Steinhaus DM, Lemery R, Brenahan DR, et al. Initial experience with an implantable hemodynamic monitor. Circulation 1996; 93:745-752.
    • (1996) Circulation , vol.93 , pp. 745-752
    • Steinhaus, D.M.1    Lemery, R.2    Brenahan, D.R.3
  • 8
    • 0029801503 scopus 로고    scopus 로고
    • Long-term recording of cardiac output via an implantable haemodynamic monitoring device
    • Ohlsson A, Bennett T, Ottenhoff F, et al. Long-term recording of cardiac output via an implantable haemodynamic monitoring device. Eur Heart J 1996; 17:1902-1910.
    • (1996) Eur Heart J , vol.17 , pp. 1902-1910
    • Ohlsson, A.1    Bennett, T.2    Ottenhoff, F.3
  • 9
    • 0031937780 scopus 로고    scopus 로고
    • Continuous ambulatory haemodynamic monitoring with an implantable system. The feasibility of a new technique
    • Ohlsson A, Nordlander R, Bennett T, et al. Continuous ambulatory haemodynamic monitoring with an implantable system. The feasibility of a new technique. Eur Heart J 1998; 19:174-184.
    • (1998) Eur Heart J , vol.19 , pp. 174-184
    • Ohlsson, A.1    Nordlander, R.2    Bennett, T.3
  • 10
    • 0028929801 scopus 로고
    • Measurement of pulmonary artery diastolic pressure from the right ventricle
    • Reynolds D, Bartelt N, Taepke RT, et al. Measurement of pulmonary artery diastolic pressure from the right ventricle. J Am Coll Cardiol 1995; 25:1176-1182.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1176-1182
    • Reynolds, D.1    Bartelt, N.2    Taepke, R.T.3
  • 11
    • 0029257708 scopus 로고
    • Monitoring of pulmonary arterial diastolic pressure through a right ventricular pressure transducer
    • Ohlsson A, Bennett T, Nordlander R, et al. Monitoring of pulmonary arterial diastolic pressure through a right ventricular pressure transducer. J Cardiac Failure 1995; 1:161-168.
    • (1995) J Cardiac Failure , vol.1 , pp. 161-168
    • Ohlsson, A.1    Bennett, T.2    Nordlander, R.3
  • 12
    • 0030098381 scopus 로고    scopus 로고
    • Measurement of pulmonary artery diastolic pressure from a right ventricular pressure transducer in patients with heart failure
    • Chuang PP, Wilson RF, Homans DC, et al. Measurement of pulmonary artery diastolic pressure from a right ventricular pressure transducer in patients with heart failure. J Cardiac Failure 1996; 2:41-46.
    • (1996) J Cardiac Failure , vol.2 , pp. 41-46
    • Chuang, P.P.1    Wilson, R.F.2    Homans, D.C.3
  • 13
    • 0034930013 scopus 로고    scopus 로고
    • Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable hemodynamic monitor: Results of a 1year multicenter feasibility study
    • Ohlsson A, Kubo S, Steinhaus D, et al. Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable hemodynamic monitor: Results of a 1year multicenter feasibility study. Eur Heart J 2001; 22:942-954.
    • (2001) Eur Heart J , vol.22 , pp. 942-954
    • Ohlsson, A.1    Kubo, S.2    Steinhaus, D.3
  • 14
    • 0036097960 scopus 로고    scopus 로고
    • Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: 12-Month follow-up in a multi-center trial of chronic heart failure patients
    • Magalski A, Adamson P, Gadler F, et al. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: 12-month follow-up in a multi-center trial of chronic heart failure patients. J Card Failure 2002; 8:63-70.
    • (2002) J Card Failure , vol.8 , pp. 63-70
    • Magalski, A.1    Adamson, P.2    Gadler, F.3
  • 15
    • 0042441141 scopus 로고    scopus 로고
    • Serial exercise testing in heart failure patients with central hemodynamic recording using implantable hemodynamic monitors
    • Ohlsson A, Ryden L, Steinhaus D, et al. Serial exercise testing in heart failure patients with central hemodynamic recording using implantable hemodynamic monitors. Eur J Heart Fail 2003; 5:253-259.
    • (2003) Eur J Heart Fail , vol.5 , pp. 253-259
    • Ohlsson, A.1    Ryden, L.2    Steinhaus, D.3
  • 16
    • 0037454083 scopus 로고    scopus 로고
    • Ongoing right ventricular hemodynamics in heart failure
    • Adamson P, Magalski A, Braunschweig F, et al. Ongoing right ventricular hemodynamics in heart failure. J Am Coll Cardiol 2003; 41: 565-571.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 565-571
    • Adamson, P.1    Magalski, A.2    Braunschweig, F.3
  • 17
    • 23644444797 scopus 로고    scopus 로고
    • Transtelephonic monitoring of continuous hemodynamic measurements in heart failure patients
    • in press
    • Kjellström B, Igel D, Abraham J, Bennett T, Bourge R. Transtelephonic monitoring of continuous hemodynamic measurements in heart failure patients. J Telemed Telecare; in press.
    • J Telemed Telecare
    • Kjellström, B.1    Igel, D.2    Abraham, J.3    Bennett, T.4    Bourge, R.5
  • 18
    • 0024598481 scopus 로고
    • Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers
    • Lau CP, Butrous GS, Ward DE, Camm AJ. Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers. Am J Cardiol 1989; 63(12):833-838.
    • (1989) Am J Cardiol , vol.63 , Issue.12 , pp. 833-838
    • Lau, C.P.1    Butrous, G.S.2    Ward, D.E.3    Camm, A.J.4
  • 20
    • 0025017224 scopus 로고
    • Right ventricular pressure during ventricular arrhythmias in humans: Potential implications for implantable antitachycardia devices
    • Sharma AD, Bennett TD, Erickson M, Klein GJ, Yee R, Guiraudon G. Right ventricular pressure during ventricular arrhythmias in humans: Potential implications for implantable antitachycardia devices. J Am Coll Cardiol 1990; 15(3):648-655.
    • (1990) J Am Coll Cardiol , vol.15 , Issue.3 , pp. 648-655
    • Sharma, A.D.1    Bennett, T.D.2    Erickson, M.3    Klein, G.J.4    Yee, R.5    Guiraudon, G.6
  • 21
    • 0026574240 scopus 로고
    • Development of a rate adaptive pacemaker based on the maximum rate-of-rise of right ventricular pressure (RV dP/dtmax)
    • Bennett T, Sharma A, Sutton R, Camm AJ, Erickson M, Beck R. Development of a rate adaptive pacemaker based on the maximum rate-of-rise of right ventricular pressure (RV dP/dtmax). Pacing Clin Electrophysiol 1992; 15(2):219-234.
    • (1992) Pacing Clin Electrophysiol , vol.15 , Issue.2 , pp. 219-234
    • Bennett, T.1    Sharma, A.2    Sutton, R.3    Camm, A.J.4    Erickson, M.5    Beck, R.6
  • 22
    • 0027092694 scopus 로고
    • Quantitation of chronotropic response: Comparison of methods for rate-modulating permanent pacemakers
    • Kay GN. Quantitation of chronotropic response: Comparison of methods for rate-modulating permanent pacemakers. J Am Coll Cardiol 1992; 20(7):1533-41.
    • (1992) J Am Coll Cardiol , vol.20 , Issue.7 , pp. 1533-1541
    • Kay, G.N.1
  • 23
    • 0027933582 scopus 로고
    • Rate modulated pacing based on right ventricular dP/dt: Quantitative analysis of chronotropic response
    • Aug
    • Kay GN, Philippon F, Bubien RS, Plumb VJ. Rate modulated pacing based on right ventricular dP/dt: Quantitative analysis of chronotropic response. Pacing Clin Electrophysiol 1994 Aug;17(8):1344-1354.
    • (1994) Pacing Clin Electrophysiol , vol.17 , Issue.8 , pp. 1344-1354
    • Kay, G.N.1    Philippon, F.2    Bubien, R.S.3    Plumb, V.J.4
  • 24
    • 0028064862 scopus 로고
    • Longterm clinical performance of a central venous oxygen saturation sensor for rate adaptive cardiac pacing
    • Faerestrand S, Ohm OJ, Stangeland L, Heynen H, Moore A. Longterm clinical performance of a central venous oxygen saturation sensor for rate adaptive cardiac pacing. Pacing Clin Electrophysiol 1994; 17(8):1355-1372.
    • (1994) Pacing Clin Electrophysiol , vol.17 , Issue.8 , pp. 1355-1372
    • Faerestrand, S.1    Ohm, O.J.2    Stangeland, L.3    Heynen, H.4    Moore, A.5
  • 25
    • 0028148531 scopus 로고
    • Quantitative comparison of rate response and oxygen uptake kinetics between different sensor modes in multisensor rate adaptive pacing
    • Leung SK, Lau CP, Wu CW, Leung WH, Tai YT, Lee I, Chow YH. Quantitative comparison of rate response and oxygen uptake kinetics between different sensor modes in multisensor rate adaptive pacing. Pacing Clin Electrophysiol 1994;17(11 Pt 2):1920-1927.
    • (1994) Pacing Clin Electrophysiol , vol.17 , Issue.11 PART 2 , pp. 1920-1927
    • Leung, S.K.1    Lau, C.P.2    Wu, C.W.3    Leung, W.H.4    Tai, Y.T.5    Lee, I.6    Chow, Y.H.7
  • 26
    • 0028595961 scopus 로고
    • Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: Quantification of chronotropic behavior during daily activities and maximal exercise
    • Lau CP, Tai YT, Leung WH, Leung SK, Li JP, Wong CK, Lee IS, Yerich C, Erickson M. Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: Quantification of chronotropic behavior during daily activities and maximal exercise. Pacing Clin Electrophysiol 1994;17(12 Pt 1):2236-2246.
    • (1994) Pacing Clin Electrophysiol , vol.17 , Issue.12 PART 1 , pp. 2236-2246
    • Lau, C.P.1    Tai, Y.T.2    Leung, W.H.3    Leung, S.K.4    Li, J.P.5    Wong, C.K.6    Lee, I.S.7    Yerich, C.8    Erickson, M.9
  • 27
    • 0028967071 scopus 로고
    • Utility of an irnplantable right ventricular oxygen saturation-sensing pacemaker for ambulatory cardiopulmonary monitoring
    • Lau CP, Tai YT, Lee IS, Erickson M, Yerich C. Utility of an irnplantable right ventricular oxygen saturation-sensing pacemaker for ambulatory cardiopulmonary monitoring. Chest 1995;107(4)1089-1094.
    • (1995) Chest , vol.107 , Issue.4 , pp. 1089-1094
    • Lau, C.P.1    Tai, Y.T.2    Lee, I.S.3    Erickson, M.4    Yerich, C.5
  • 28
    • 0029127009 scopus 로고
    • Relationship between heart rate and oxygen kinetics during constant workload exercise
    • Kay GN, Ashar MS, Bubien RS, Dailey SM. Relationship between heart rate and oxygen kinetics during constant workload exercise. Pacing Clin Electrophysiol 1995;18(10):1853-1860.
    • (1995) Pacing Clin Electrophysiol , vol.18 , Issue.10 , pp. 1853-1860
    • Kay, G.N.1    Ashar, M.S.2    Bubien, R.S.3    Dailey, S.M.4
  • 29
    • 0031878561 scopus 로고    scopus 로고
    • Two-year experience with rate-modulated pacing controlled by mixed venous oxygen saturation
    • Windecker S, Bubien RS, Halperin L, Moore A, Kay GN. Two-year experience with rate-modulated pacing controlled by mixed venous oxygen saturation. Pacing Clin Electrophysiol 1998;21(7):1396-1404.
    • (1998) Pacing Clin Electrophysiol , vol.21 , Issue.7 , pp. 1396-1404
    • Windecker, S.1    Bubien, R.S.2    Halperin, L.3    Moore, A.4    Kay, G.N.5
  • 31
    • 0036401347 scopus 로고    scopus 로고
    • Continuous hemodynamic monitoring during withdrawal of diuretics in patients with congestive heart failure
    • Braunschweig F, Linde C, Eriksson MJ, Hofman-Bang C, Ryden L. Continuous hemodynamic monitoring during withdrawal of diuretics in patients with congestive heart failure. Eur Heart J 2002; 23(1): 59-69.
    • (2002) Eur Heart J , vol.23 , Issue.1 , pp. 59-69
    • Braunschweig, F.1    Linde, C.2    Eriksson, M.J.3    Hofman-Bang, C.4    Ryden, L.5
  • 32
    • 0036155098 scopus 로고    scopus 로고
    • Continuous hemodynamic monitoring in heart failure
    • Braunschweig F, Linde C. Continuous hemodynamic monitoring in heart failure. J Cardiovasc Electrophysiol 2002;13(Suppl.):68-72.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , Issue.SUPPL. , pp. 68-72
    • Braunschweig, F.1    Linde, C.2
  • 33
    • 0742307379 scopus 로고    scopus 로고
    • The potential of continuous hemodynamic monitoring for the optimization of pacemaker algorithms in patients with heart failure. A case report
    • Braunschweig F, Kjellström B, Gadler F, Linde C. The potential of continuous hemodynamic monitoring for the optimization of pacemaker algorithms in patients with heart failure. A case report. J Cardiovasc Electrophysiol 2004; 15:94-96
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 94-96
    • Braunschweig, F.1    Kjellström, B.2    Gadler, F.3    Linde, C.4
  • 34
    • 0038826796 scopus 로고    scopus 로고
    • Continuous haemodynamic monitoring in pulmonary hypertensive patients treated with inhaled iloprost
    • Fruhwald F, Kjellström B, Perthold W, Watzinger N, Maier R, Grandjean P, Klein W. Continuous haemodynamic monitoring in pulmonary hypertensive patients treated with inhaled iloprost. Chest 2003; 124:351-359.
    • (2003) Chest , vol.124 , pp. 351-359
    • Fruhwald, F.1    Kjellström, B.2    Perthold, W.3    Watzinger, N.4    Maier, R.5    Grandjean, P.6    Klein, W.7
  • 35
    • 18844372029 scopus 로고    scopus 로고
    • Hemodynamic observations in two pulmonary hypertensive patients changing treatment from inhaled iloprost to oral endothelin-antagonist Bosentan
    • in press
    • Fruhwald F, Kjellström B, Perthold W, Wonisch M, Maier R, Grandjean P, Klein W. Hemodynamic observations in two pulmonary hypertensive patients changing treatment from inhaled iloprost to oral endothelin-antagonist Bosentan. J Heart Lung Transplant (in press).
    • J Heart Lung Transplant
    • Fruhwald, F.1    Kjellström, B.2    Perthold, W.3    Wonisch, M.4    Maier, R.5    Grandjean, P.6    Klein, W.7
  • 36
    • 0032887194 scopus 로고    scopus 로고
    • Use of tele-monitoring to decrease the rate of hospitalization in patients with severe congestive heart failure
    • Cordisco ME, Beniaminovitz A, Hammond K, et al. Use of tele-monitoring to decrease the rate of hospitalization in patients with severe congestive heart failure. Am J Card 1999; 84:860-862.
    • (1999) Am J Card , vol.84 , pp. 860-862
    • Cordisco, M.E.1    Beniaminovitz, A.2    Hammond, K.3
  • 37
    • 0347361323 scopus 로고    scopus 로고
    • A systematic review of tele-monitoring for the management of heart failure
    • Louis A, Turner T, Gretton M, Baksh A, Cleland J. A systematic review of tele-monitoring for the management of heart failure. Eur J Heart Fail 2003; 5:586-590.
    • (2003) Eur J Heart Fail , vol.5 , pp. 586-590
    • Louis, A.1    Turner, T.2    Gretton, M.3    Baksh, A.4    Cleland, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.