메뉴 건너뛰기




Volumn 21, Issue 7, 1998, Pages 1396-1404

Two-year experience with rate-modulated pacing controlled by mixed venous oxygen saturation

Author keywords

Cardiac pacing; Mixed venous oxy hemoglobin saturation; Rate adaptive pacing; Sensors

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; BIOSENSOR; CHRONOTROPISM; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED STUDY; DEVICE; EXERCISE TEST; FEMALE; HEART RATE; HEART VENTRICLE PACING; HUMAN; MALE; OXYGEN CONSUMPTION; PATIENT MONITORING; VENOUS OXYGEN TENSION;

EID: 0031878561     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1998.tb00210.x     Document Type: Article
Times cited : (9)

References (18)
  • 1
    • 0020445149 scopus 로고
    • Central venous oxygen saturation for the control of automatic rate-responsive pacing
    • Wirtzfeld A, Goedel-Meinen L, Bock T, et al. Central venous oxygen saturation for the control of automatic rate-responsive pacing. PACE 1982; 5:829-835.
    • (1982) PACE , vol.5 , pp. 829-835
    • Wirtzfeld, A.1    Goedel-Meinen, L.2    Bock, T.3
  • 2
    • 0021712997 scopus 로고
    • Regulation of pacing rate by variations of mixed venous oxygen saturation
    • Wirtzfeld A, Heinze R, Stangl K, et al. Regulation of pacing rate by variations of mixed venous oxygen saturation. PACE 1984; 7:1257-1262.
    • (1984) PACE , vol.7 , pp. 1257-1262
    • Wirtzfeld, A.1    Heinze, R.2    Stangl, K.3
  • 4
    • 0024253713 scopus 로고
    • A new multisensor pacing system using stroke volume, respiratory rate, mixed venous oxygen saturation, temperature, right atrial pressure, right ventricular pressure, and dP/dt
    • Stangl K, Wirtzfeld A, Heinze R, et al. A new multisensor pacing system using stroke volume, respiratory rate, mixed venous oxygen saturation, temperature, right atrial pressure, right ventricular pressure, and dP/dt. PACE 1988; 11:712-723.
    • (1988) PACE , vol.11 , pp. 712-723
    • Stangl, K.1    Wirtzfeld, A.2    Heinze, R.3
  • 5
    • 0024317907 scopus 로고
    • Abrupt changes in mixed venous blood gas composition after the onset of exercise
    • Casaburi R, Daly J, Hansen JE, et al. Abrupt changes in mixed venous blood gas composition after the onset of exercise. J Appl Physiol 1989; 67:1106-1112.
    • (1989) J Appl Physiol , vol.67 , pp. 1106-1112
    • Casaburi, R.1    Daly, J.2    Hansen, J.E.3
  • 6
    • 0025670106 scopus 로고
    • Relationship between right atrial and mixed venous oxygen saturation and heart rate during exercise in normal subjects and patients with cardiac disease
    • French WJ, Casaburi R, Lewis DA, et al. Relationship between right atrial and mixed venous oxygen saturation and heart rate during exercise in normal subjects and patients with cardiac disease. PACE 1990; 13:1809-1815.
    • (1990) PACE , vol.13 , pp. 1809-1815
    • French, W.J.1    Casaburi, R.2    Lewis, D.A.3
  • 7
    • 0344164835 scopus 로고
    • Rate-modulated pacing controlled by mixed venous oxygen saturation
    • KA Ellenbogen, GN Kay, BL Wilkoff (eds.): W.B. Saunders, Philadelphia
    • Kay GN, Bornzin GA. Rate-modulated pacing controlled by mixed venous oxygen saturation. In KA Ellenbogen, GN Kay, BL Wilkoff (eds.): Clinical Cardiac Pacing, W.B. Saunders, Philadelphia, 1995, pp. 187-200.
    • (1995) Clinical Cardiac Pacing , pp. 187-200
    • Kay, G.N.1    Bornzin, G.A.2
  • 8
    • 0025784284 scopus 로고
    • Mixed venous oxygen saturation for differentiating stable from unstable tachycardias
    • Cohen TJ, Liem LB. Mixed venous oxygen saturation for differentiating stable from unstable tachycardias. Am Heart J 1991; 122:733-740.
    • (1991) Am Heart J , vol.122 , pp. 733-740
    • Cohen, T.J.1    Liem, L.B.2
  • 9
    • 0025951362 scopus 로고
    • In vivo and in vitro studies of a chronic oxygen sensor
    • Seifert GP, Moore AA, Graves KL, et al. In vivo and in vitro studies of a chronic oxygen sensor. PACE 1991; 14:1514-1527.
    • (1991) PACE , vol.14 , pp. 1514-1527
    • Seifert, G.P.1    Moore, A.A.2    Graves, K.L.3
  • 10
    • 0028064862 scopus 로고
    • Long-term clinical performance of a central venous oxygen saturation sensor for rate adaptive cardiac pacing
    • Faerestrand S, Ohm O-J, Stangeland L, et al. Long-term clinical performance of a central venous oxygen saturation sensor for rate adaptive cardiac pacing. PACE 1994; 17:1355-1372.
    • (1994) PACE , vol.17 , pp. 1355-1372
    • Faerestrand, S.1    Ohm, O.-J.2    Stangeland, L.3
  • 11
    • 0023001485 scopus 로고
    • Sensors in pacing
    • Anderson KM, Moore AA. Sensors in pacing. PACE 1986; 9:953-972.
    • (1986) PACE , vol.9 , pp. 953-972
    • Anderson, K.M.1    Moore, A.A.2
  • 12
    • 1842299234 scopus 로고
    • In vivo studies with an intravascular and intracardiac reflection oximeter
    • Enson Y, Briscoe W, Polanyi M, et al. In vivo studies with an intravascular and intracardiac reflection oximeter. J Appl Physiol 1962; 17:552-558.
    • (1962) J Appl Physiol , vol.17 , pp. 552-558
    • Enson, Y.1    Briscoe, W.2    Polanyi, M.3
  • 13
    • 0000754869 scopus 로고
    • The absorption spectra of hemoglobin and its derivatives in the visible and near infra-red regions
    • Horecker B. The absorption spectra of hemoglobin and its derivatives in the visible and near infra-red regions. J Biol Chem 1943; 148:173-179.
    • (1943) J Biol Chem , vol.148 , pp. 173-179
    • Horecker, B.1
  • 15
    • 0003061029 scopus 로고
    • A chronotropic assessment exercise protocol to assess the need and efficacy of rate-responsive pacing
    • Blackburn G, Harvey S, Wilkoff B. A chronotropic assessment exercise protocol to assess the need and efficacy of rate-responsive pacing, (abstract) Med Sci Sports Exer 1988; 20:S21.
    • (1988) Med Sci Sports Exer , vol.20
    • Blackburn, G.1    Harvey, S.2    Wilkoff, B.3
  • 16
    • 0024231917 scopus 로고
    • First clinical experience with an oxygen saturation controlled pacemaker in man
    • Stangl K, Wirtzfeld A, Heinze R, et al. First clinical experience with an oxygen saturation controlled pacemaker in man. PACE 1988; 11:1882-1887.
    • (1988) PACE , vol.11 , pp. 1882-1887
    • Stangl, K.1    Wirtzfeld, A.2    Heinze, R.3
  • 17
    • 0028595961 scopus 로고
    • Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: Quantitation of chronotropic behavior during daily activities and maximal exercise
    • Lau C-P, Tai Y-T, Leung W-H, et al. Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: Quantitation of chronotropic behavior during daily activities and maximal exercise. PACE 1994; 17:2236-2246.
    • (1994) PACE , vol.17 , pp. 2236-2246
    • Lau, C.-P.1    Tai, Y.-T.2    Leung, W.-H.3
  • 18
    • 0015380386 scopus 로고
    • Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode
    • Becker AE, Becker MJ, Claudon DG, et al. Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode. Circulation 1972; 46:409-412.
    • (1972) Circulation , vol.46 , pp. 409-412
    • Becker, A.E.1    Becker, M.J.2    Claudon, D.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.