메뉴 건너뛰기




Volumn 46, Issue 12, 2004, Pages 955-972

MR angiography of the intracranial vessels: Technical aspects and clinical applications

Author keywords

Aneurysm; Arteriovenous malformations; Infarction; Intracranial; Magnetic resonance; Vascular studies

Indexed keywords

CONTRAST MEDIUM; GADOLINIUM; GADOLINIUM CHELATE;

EID: 20444460811     PISSN: 00283940     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00234-004-1297-9     Document Type: Review
Times cited : (112)

References (65)
  • 1
    • 0028876757 scopus 로고
    • Time-of-flight MR angiography of the brain: Comparison of acquisition techniques in healthy volunteers
    • 1:STN:280:ByqD1M7hslM%3D
    • Bosmans H, Marchal G, Lukito G, Yicheng N, Wilms G, Laub G, Baert AL (1995) Time-of-flight MR angiography of the brain: Comparison of acquisition techniques in healthy volunteers. Am J Roentgenol 164:161-167 1:STN:280:ByqD1M7hslM%3D
    • (1995) Am. J. Roentgenol. , vol.164 , pp. 161-167
    • Bosmans, H.1    Marchal, G.2    Lukito, G.3    Yicheng, N.4    Wilms, G.5    Laub, G.6    Baert, A.L.7
  • 2
    • 0035313193 scopus 로고    scopus 로고
    • Magnetic resonance angiography of the intracranial vessels
    • 10.1016/S0720-048X(01)00285-6
    • Wilms G, Bosmans H, Demaerel Ph, Marchal G (2001) Magnetic resonance angiography of the intracranial vessels. Eur J Radiol 38:10-18 10.1016/ S0720-048X(01)00285-6
    • (2001) Eur. J. Radiol. , vol.38 , pp. 10-18
    • Wilms, G.1    Bosmans, H.2    Demaerel, Ph.3    Marchal, G.4
  • 3
    • 0026748250 scopus 로고
    • Cerebral MR angiography with multiple overlapping thin slab acquisition. Part II. Early clinical experience
    • 1:STN:280:By2B38%2Fps1E%3D
    • Blatter DD, Parker DL, Ah SS, Bahr AL, Robinson RO, Schwartz RB, Jolesz FA, Boyer RS (1992) Cerebral MR angiography with multiple overlapping thin slab acquisition. Part II. Early clinical experience. Radiology 183:379-389 1:STN:280:By2B38%2Fps1E%3D
    • (1992) Radiology , vol.183 , pp. 379-389
    • Blatter, D.D.1    Parker, D.L.2    Ah, S.S.3    Bahr, A.L.4    Robinson, R.O.5    Schwartz, R.B.6    Jolesz, F.A.7    Boyer, R.S.8
  • 4
    • 0028799606 scopus 로고
    • Combined effects of magnetization transfer and gadolinium in cranial MR imaging and MR angiography
    • 1:STN:280:ByqD1M7hslw%3D
    • Mathews VP, Elster AD, King JC, Ulmer JL, Hamilton CA, Strottmann JM (1995) Combined effects of magnetization transfer and gadolinium in cranial MR imaging and MR angiography. Am J Roentgenol 164:169-172 1:STN:280:ByqD1M7hslw%3D
    • (1995) Am. J. Roentgenol. , vol.164 , pp. 169-172
    • Mathews, V.P.1    Elster, A.D.2    King, J.C.3    Ulmer, J.L.4    Hamilton, C.A.5    Strottmann, J.M.6
  • 6
    • 0028203418 scopus 로고
    • Improved MR angiography magnetization transfer suppression with variable flip angle excitation and increased resolution
    • 1:STN:280:ByuC2MbovFc%3D
    • Atkinson D, Brandt-Zawadzki M, Gillan G, Purdy D, Laub G (1994) Improved MR angiography magnetization transfer suppression with variable flip angle excitation and increased resolution. Radiology 190:890-894 1:STN:280:ByuC2MbovFc%3D
    • (1994) Radiology , vol.190 , pp. 890-894
    • Atkinson, D.1    Brandt-Zawadzki, M.2    Gillan, G.3    Purdy, D.4    Laub, G.5
  • 8
    • 8344227646 scopus 로고    scopus 로고
    • Low-dose gadolinium enhanced 3D time-of-flight MR angiography of the intracranial vessels using PAT optimized phased array 8-channel head coil
    • Özsarlak Ö., Parizel PM, Van Goethem JW (2004) Low-dose gadolinium enhanced 3D time-of-flight MR angiography of the intracranial vessels using PAT optimized phased array 8-channel head coil. Eur Radiol 14:2067-2071
    • (2004) Eur. Radiol. , vol.14 , pp. 2067-2071
    • Özsarlak, Ö.1    Parizel, P.M.2    Van Goethem, J.W.3
  • 9
    • 0028786284 scopus 로고
    • Contrast-enhanced MR angiography for the diagnosis of intracranial vascular disease: Optimal dose of gadopentate dimeglumine
    • 1:STN:280:BymD387ps1E%3D
    • Jung HW, Chang KH, Choi DS, Han MH, Han MC (1995) Contrast-enhanced MR angiography for the diagnosis of intracranial vascular disease: Optimal dose of gadopentate dimeglumine. Am J Roentgenol 165:1251-1255 1:STN:280:BymD387ps1E%3D
    • (1995) Am. J. Roentgenol. , vol.165 , pp. 1251-1255
    • Jung, H.W.1    Chang, K.H.2    Choi, D.S.3    Han, M.H.4    Han, M.C.5
  • 10
    • 0024542982 scopus 로고
    • Three-dimensional phase contrast angiography
    • 1:STN:280:BiaB3MflslM%3D
    • Dumoulin CL, Souza SP, Walker MF, Wagle W (1989) Three-dimensional phase contrast angiography. Magn Reson Med 9:139-149 1:STN:280:BiaB3MflslM%3D
    • (1989) Magn. Reson. Med. , vol.9 , pp. 139-149
    • Dumoulin, C.L.1    Souza, S.P.2    Walker, M.F.3    Wagle, W.4
  • 11
    • 0026512065 scopus 로고
    • Determination of cerebral blood flow with a phase-contrast cine MR imaging technique: Evaluation of normal subjects and patients with arteriovenous malformation
    • 1:STN:280:By2C38zovFI%3D
    • Marks MP, Pelc MJ, Ross MR, Enzmann DR (1992) Determination of cerebral blood flow with a phase-contrast cine MR imaging technique: Evaluation of normal subjects and patients with arteriovenous malformation. Radiology 182:467-476 1:STN:280:By2C38zovFI%3D
    • (1992) Radiology , vol.182 , pp. 467-476
    • Marks, M.P.1    Pelc, M.J.2    Ross, M.R.3    Enzmann, D.R.4
  • 12
    • 0031660607 scopus 로고    scopus 로고
    • Intracranial vascular stenosis and occlusion: Comparison of 3D time-of-flight and 3D phase-contrast MR angiography
    • 10.1007/s002340050645
    • Oelerich M, Lentschig MG, Zunker P, Reimer P, Rummeny EJ, Schuierer G (1998) Intracranial vascular stenosis and occlusion: Comparison of 3D time-of-flight and 3D phase-contrast MR angiography. Neuroradiology 40:567-573 10.1007/s002340050645
    • (1998) Neuroradiology , vol.40 , pp. 567-573
    • Oelerich, M.1    Lentschig, M.G.2    Zunker, P.3    Reimer, P.4    Rummeny, E.J.5    Schuierer, G.6
  • 13
    • 0031839758 scopus 로고    scopus 로고
    • MR angiography: Basic principles and theory
    • 1:STN:280:DyaK1c3ivVektg%3D%3D
    • Korosec FR, Mistretta CA (1998) MR angiography: Basic principles and theory. Magn Reson Imaging Clin N Am 6:223-256 1:STN:280:DyaK1c3ivVektg%3D%3D
    • (1998) Magn. Reson. Imaging Clin. N. Am. , vol.6 , pp. 223-256
    • Korosec, F.R.1    Mistretta, C.A.2
  • 14
    • 0347132445 scopus 로고    scopus 로고
    • Phase-contrast magnetic resonance angiography
    • 1:STN:280:DC%2BD2c%2FkslCqtw%3D%3D
    • Van Goethem JW, Hauwe L van den, Ozsarlak O, Parizel PM (2003) Phase-contrast magnetic resonance angiography. JBR-BTR 86:340-44 1:STN:280:DC%2BD2c%2FkslCqtw%3D%3D
    • (2003) JBR-BTR , vol.86 , pp. 340-344
    • Van Goethem, J.W.1    van den Hauwe, L.2    Ozsarlak, O.3    Parizel, P.M.4
  • 15
    • 0033917477 scopus 로고    scopus 로고
    • Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography
    • 1:STN:280:DC%2BD3czksl2ruw%3D%3D
    • Hilfiker PR, Herfkens RJ, Heiss SG, Alley MT, Fleischmann D, Pelc NJ (2000) Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography. Radiology 216:298-303 1:STN:280:DC%2BD3czksl2ruw%3D%3D
    • (2000) Radiology , vol.216 , pp. 298-303
    • Hilfiker, P.R.1    Herfkens, R.J.2    Heiss, S.G.3    Alley, M.T.4    Fleischmann, D.5    Pelc, N.J.6
  • 16
    • 0033997180 scopus 로고    scopus 로고
    • Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: Design specifications and technical reliability in 330 patient studies
    • 1:STN:280:DC%2BD3c3lslSjuw%3D%3D
    • Riederer SJ, Bernstein MA, Breen JF, Busse RF, Ehman RI, Fain SB, Hulshizer TC, Iii JH, King BF, Kruger DG, Rosmann PJ, Shah S (2000) Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: Design specifications and technical reliability in 330 patient studies. Radiology 215:584-593 1:STN:280:DC%2BD3c3lslSjuw%3D%3D
    • (2000) Radiology , vol.215 , pp. 584-593
    • Riederer, S.J.1    Bernstein, M.A.2    Breen, J.F.3    Busse, R.F.4    Ehman, R.I.5    Fain, S.B.6    Hulshizer, T.C.7    Iii, J.H.8    King, B.F.9    Kruger, D.G.10    Rosmann, P.J.11    Shah, S.12
  • 17
    • 0030038784 scopus 로고    scopus 로고
    • Pulsed magnetization transfer contrast MRI by a sequence with water selective excitation
    • 10.1097/00004728-199601000-00014
    • Schick F (1996) Pulsed magnetization transfer contrast MRI by a sequence with water selective excitation. J Comput Assist Tomogr 20:73-79 10.1097/ 00004728-199601000-00014
    • (1996) J. Comput. Assist. Tomogr. , vol.20 , pp. 73-79
    • Schick, F.1
  • 20
    • 0031877408 scopus 로고    scopus 로고
    • A 16-element phased-array head coil
    • 1:STN:280:DyaK1czmvVSqsw%3D%3D
    • Porter JR, Wright SM, Reykowski A (1998) A 16-element phased-array head coil. Magn Reson Med 40:272-279 1:STN:280:DyaK1czmvVSqsw%3D%3D
    • (1998) Magn. Reson. Med. , vol.40 , pp. 272-279
    • Porter, J.R.1    Wright, S.M.2    Reykowski, A.3
  • 21
    • 0036137464 scopus 로고    scopus 로고
    • Recent advances in image reconstruction, coil sensitivity calibration, and coil design for SMASH and generalized parallel MRI
    • 11755091
    • Sodickson DK, McKenzie CA, Ohliger MA, Yeh AN, Price MD (2002) Recent advances in image reconstruction, coil sensitivity calibration, and coil design for SMASH and generalized parallel MRI. MAGMA 13:158-163 11755091
    • (2002) MAGMA , vol.13 , pp. 158-163
    • Sodickson, D.K.1    McKenzie, C.A.2    Ohliger, M.A.3    Yeh, A.N.4    Price, M.D.5
  • 22
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.3.CO;2-J
    • Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Mag Reson Med 42:952-962 10.1002/ (SICI)1522-2594(199911)42:5<952::AID-MRM16>3.3.CO;2-J
    • (1999) Mag. Reson. Med. , vol.42 , pp. 952-962
    • Pruessmann, K.P.1    Weiger, M.2    Scheidegger, M.B.3    Boesiger, P.4
  • 25
    • 0036099935 scopus 로고    scopus 로고
    • Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries
    • 10.1016/S0730-725X(02)00486-1
    • Al-Kwifi O, Emery DJ, Wilman AH (2002) Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries. Magn Reson Imaging 20:181-187 10.1016/ S0730-725X(02)00486-1
    • (2002) Magn. Reson. Imaging , vol.20 , pp. 181-187
    • Al-Kwifi, O.1    Emery, D.J.2    Wilman, A.H.3
  • 26
    • 0026478777 scopus 로고
    • Intracranial vascular stenosis and occlusion: Evaluation with three-dimensional time-of-flight MR angiography
    • 1:STN:280:ByyD28nps1c%3D
    • Heiserman JE, Drayer BP, Keller PJ, Fram EK (1992) Intracranial vascular stenosis and occlusion: Evaluation with three-dimensional time-of-flight MR angiography. Radiology 185:667-673 1:STN:280:ByyD28nps1c%3D
    • (1992) Radiology , vol.185 , pp. 667-673
    • Heiserman, J.E.1    Drayer, B.P.2    Keller, P.J.3    Fram, E.K.4
  • 28
    • 0036155748 scopus 로고    scopus 로고
    • Prospective evaluation of suspected steno-occlusive disease of the intracranial artery: Combined MR angiography and CT angiography compared with digital subtraction angiography
    • 11827880
    • Hirai T, Korogi Y, Ono K, Nagano M, Maruoka K, Uemura S, Takahashi M (2002) Prospective evaluation of suspected steno-occlusive disease of the intracranial artery: Combined MR angiography and CT angiography compared with digital subtraction angiography. Am J Neuroradiol 23:93-101 11827880
    • (2002) Am. J. Neuroradiol. , vol.23 , pp. 93-101
    • Hirai, T.1    Korogi, Y.2    Ono, K.3    Nagano, M.4    Maruoka, K.5    Uemura, S.6    Takahashi, M.7
  • 31
    • 0029818282 scopus 로고    scopus 로고
    • Magnetic resonance angiography in the management of aneurysmal subarachnoid hemorrhage: A study of 51 cases
    • 10.1007/s002340050336
    • Sankhla SK, Gunawardena WJ, Coutinho CMA, Jones AP, Keogh AJ (1996) Magnetic resonance angiography in the management of aneurysmal subarachnoid hemorrhage: A study of 51 cases. Neuroradiology 38:724-729 10.1007/s002340050336
    • (1996) Neuroradiology , vol.38 , pp. 724-729
    • Sankhla, S.K.1    Gunawardena, W.J.2    Coutinho, C.M.A.3    Jones, A.P.4    Keogh, A.J.5
  • 32
    • 0029018358 scopus 로고
    • Characterization of intracranial aneurysms with MR angiography
    • 10.1007/s002340050085
    • Bosmans H, Wilms G, Marchal G, Demaerel P, Baert AL (1995) Characterization of intracranial aneurysms with MR angiography. Neuroradiology 37:262-266 10.1007/s002340050085
    • (1995) Neuroradiology , vol.37 , pp. 262-266
    • Bosmans, H.1    Wilms, G.2    Marchal, G.3    Demaerel, P.4    Baert, A.L.5
  • 33
    • 0033772515 scopus 로고    scopus 로고
    • The role of MR angiography in the pretreatment assessment of intracranial aneurysms: A comparative study
    • 1:STN:280:DC%2BD3cvovVersg%3D%3D
    • Adams WM, Laitt RD, Jackson A (2000) The role of MR angiography in the pretreatment assessment of intracranial aneurysms: A comparative study. Am J Neuroradiol 21:1618-1628 1:STN:280:DC%2BD3cvovVersg%3D%3D
    • (2000) Am. J. Neuroradiol. , vol.21 , pp. 1618-1628
    • Adams, W.M.1    Laitt, R.D.2    Jackson, A.3
  • 34
    • 0037742304 scopus 로고    scopus 로고
    • The non-invasive detection of intracranial aneurysms: Are neuroradiologists any better than other observers?
    • 12599005
    • White PM, Wardlaw JM, Lindsay KW, Sloss S, Patel DK, Teasdale EM (2003) The non-invasive detection of intracranial aneurysms: Are neuroradiologists any better than other observers? Eur Radiol 13:389-396 12599005
    • (2003) Eur. Radiol. , vol.13 , pp. 389-396
    • White, P.M.1    Wardlaw, J.M.2    Lindsay, K.W.3    Sloss, S.4    Patel, D.K.5    Teasdale, E.M.6
  • 37
    • 0028283928 scopus 로고
    • Endovascular occlusion of intracranial aneurysms with electrolytically detachable coils: Correlation of aneurysm neck size and treatment results
    • 1:STN:280:ByuA3sjmsVY%3D
    • Fernandez-Zubillaga A, Guglielmi G, Vinuela F, Duckwiler G (1994) Endovascular occlusion of intracranial aneurysms with electrolytically detachable coils: Correlation of aneurysm neck size and treatment results. Am J Neuroradiol 15:815-820 1:STN:280:ByuA3sjmsVY%3D
    • (1994) Am. J. Neuroradiol. , vol.15 , pp. 815-820
    • Fernandez-Zubillaga, A.1    Guglielmi, G.2    Vinuela, F.3    Duckwiler, G.4
  • 39
    • 0344631109 scopus 로고    scopus 로고
    • MR angiography with three-dimensional time-of-flight and targeted maximum-intensity-projection reconstructions in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils
    • 1:STN:280:DyaK1MvktVOrtg%3D%3D
    • Kähära VJ, Seppanen SK, Ryymin PS, Mattila P, Kuurne T, Laasonen EM (1999) MR angiography with three-dimensional time-of-flight and targeted maximum-intensity-projection reconstructions in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils. Am J Neuroradiol 20:1470-1475 1:STN:280:DyaK1MvktVOrtg%3D%3D
    • (1999) Am. J. Neuroradiol. , vol.20 , pp. 1470-1475
    • Kähära, V.J.1    Seppanen, S.K.2    Ryymin, P.S.3    Mattila, P.4    Kuurne, T.5    Laasonen, E.M.6
  • 40
    • 0034072972 scopus 로고    scopus 로고
    • Three-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils
    • 1:STN:280:DC%2BD3c3kt1yrsQ%3D%3D
    • Anzalone N, Righi C, Simionato F, Scomazzoni F, Pagani G, Calori G, Santino P, Scotti G (2000) Three-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils. Am J Neuroradiol 21:746-752 1:STN:280:DC%2BD3c3kt1yrsQ%3D%3D
    • (2000) Am. J. Neuroradiol. , vol.21 , pp. 746-752
    • Anzalone, N.1    Righi, C.2    Simionato, F.3    Scomazzoni, F.4    Pagani, G.5    Calori, G.6    Santino, P.7    Scotti, G.8
  • 41
    • 0035082312 scopus 로고    scopus 로고
    • Follow-up intracranial aneurysms treated with detachable coils: comparison of gadolinium enhanced 3D time-of-flight MR angiography and digital subtraction angiography
    • 1:STN:280:DC%2BD3M7oslKhsw%3D%3D
    • Boulin A, Pierot L (2001) Follow-up intracranial aneurysms treated with detachable coils: Comparison of gadolinium enhanced 3D time-of-flight MR angiography and digital subtraction angiography. Radiology 219:108-113 1:STN:280:DC%2BD3M7oslKhsw%3D%3D
    • (2001) Radiology , vol.219 , pp. 108-113
    • Boulin, A.1    Pierot, L.2
  • 42
    • 0036677918 scopus 로고    scopus 로고
    • Aneurysms of the anterior communicating artery treated with Guglielmi detachable coils: Follow-up with contrast-enhanced MR angiography
    • 12169468
    • Leclerc X, Navez JF, Gauvrit JY, Lejeune JP, Pruvo JP (2002) Aneurysms of the anterior communicating artery treated with Guglielmi detachable coils: Follow-up with contrast-enhanced MR angiography. Am J Neuroradiol 23:1121-1127 12169468
    • (2002) Am. J. Neuroradiol. , vol.23 , pp. 1121-1127
    • Leclerc, X.1    Navez, J.F.2    Gauvrit, J.Y.3    Lejeune, J.P.4    Pruvo, J.P.5
  • 44
    • 0023619711 scopus 로고
    • Size determination of supratentorial arteriovenous malformations by MR, CT and angio
    • 10.1007/BF00350432
    • Noorbehesht B, Fabrikant JI, Enzmann DR (1987) Size determination of supratentorial arteriovenous malformations by MR, CT and angio. Neuroradiology 29:512-518 10.1007/BF00350432
    • (1987) Neuroradiology , vol.29 , pp. 512-518
    • Noorbehesht, B.1    Fabrikant, J.I.2    Enzmann, D.R.3
  • 45
    • 0034041711 scopus 로고    scopus 로고
    • Clinical significance of pedicle aneurysms on feeding vessels, especially those located in infratentorial arteriovenous malformations
    • 1:STN:280:DC%2BD3c3ps1Sksw%3D%3D
    • Westphal M, Grzyska U (2000) Clinical significance of pedicle aneurysms on feeding vessels, especially those located in infratentorial arteriovenous malformations. J Neurosurg 92:995-001 1:STN:280:DC%2BD3c3ps1Sksw%3D%3D
    • (2000) J. Neurosurg. , vol.92 , pp. 995-1001
    • Westphal, M.1    Grzyska, U.2
  • 47
    • 0034115128 scopus 로고    scopus 로고
    • MR digital subtraction angiography of cerebral arteriovenous malformations
    • 10782782
    • Tsuchiyaa K, Katasea S, Yoshinoa A, Hachiyaa J (2000) MR digital subtraction angiography of cerebral arteriovenous malformations. Am J Neuroradiol 21:707-711 10782782
    • (2000) Am. J. Neuroradiol. , vol.21 , pp. 707-711
    • Tsuchiyaa, K.1    Katasea, S.2    Yoshinoa, A.3    Hachiyaa, J.4
  • 48
    • 0036127689 scopus 로고    scopus 로고
    • The emergence of time-resolved contrast-enhanced MR imaging for intracranial angiography
    • 11900996
    • Carroll TJ (2002) The emergence of time-resolved contrast-enhanced MR imaging for intracranial angiography. Am J Neuroradiol 23:346-348 11900996
    • (2002) Am. J. Neuroradiol. , vol.23 , pp. 346-348
    • Carroll, T.J.1
  • 49
    • 0033739296 scopus 로고    scopus 로고
    • Brain arteriovenous malformations: Assessment with dynamic MR digital subtraction angiography
    • 1:STN:280:DC%2BD3M7ovVCjug%3D%3D
    • Griffiths PD, Hoggard N, Warren DJ, Wilkinson ID, Anderson B, Romanowski CA (2000) Brain arteriovenous malformations: Assessment with dynamic MR digital subtraction angiography. Am J Neuroradiol 21:1892-1899 1:STN:280:DC%2BD3M7ovVCjug%3D%3D
    • (2000) Am. J. Neuroradiol. , vol.21 , pp. 1892-1899
    • Griffiths, P.D.1    Hoggard, N.2    Warren, D.J.3    Wilkinson, I.D.4    Anderson, B.5    Romanowski, C.A.6
  • 50
    • 0033979362 scopus 로고    scopus 로고
    • Fast functional MRA using time-resolved projection MR-angiography with correlation analysis
    • 10.1002/(SICI)1522-2594(200002)43:2<303::AID-MRM19>3.0.CO;2-R
    • Strecker R, Scheffler K, Klisch J, Lehnhardt S, Winterer S, Laubenberger J, Fischer H, Hennig J (2000) Fast functional MRA using time-resolved projection MR-angiography with correlation analysis. Magn Reson Med 43:303-309 10.1002/ (SICI)1522-2594(200002)43:2<303::AID-MRM19>3.0.CO;2-R
    • (2000) Magn. Reson. Med. , vol.43 , pp. 303-309
    • Strecker, R.1    Scheffler, K.2    Klisch, J.3    Lehnhardt, S.4    Winterer, S.5    Laubenberger, J.6    Fischer, H.7    Hennig, J.8
  • 53
    • 0031759764 scopus 로고    scopus 로고
    • Aneurysmal malformation of the vein of Galen in three patients: Clinical and radiological follow-up
    • 10.1007/s002340050691
    • Campi A, Rodesch G, Scotti G, Lasjaunias P (1998) Aneurysmal malformation of the vein of Galen in three patients: Clinical and radiological follow-up. Neuoradiology 40:816-821 10.1007/s002340050691
    • (1998) Neuoradiology , vol.40 , pp. 816-821
    • Campi, A.1    Rodesch, G.2    Scotti, G.3    Lasjaunias, P.4
  • 55
    • 0025141004 scopus 로고
    • Hyperintense thrombus on GRASS MR images: Potential pitfall in flow evaluation
    • 1:STN:280:By%2BC2cvktV0%3D
    • Yousem DM, Balakrishnan J, Debrun GM, Bryan RN (1990) Hyperintense thrombus on GRASS MR images: Potential pitfall in flow evaluation. Am J Neuroradiol 11:51-58 1:STN:280:By%2BC2cvktV0%3D
    • (1990) Am. J. Neuroradiol. , vol.11 , pp. 51-58
    • Yousem, D.M.1    Balakrishnan, J.2    Debrun, G.M.3    Bryan, R.N.4
  • 57
    • 0028326873 scopus 로고
    • Dural sinus thrombosis: Value of venous MR angiography for diagnosis and follow-up
    • 1:STN:280:ByuB3Mbjt1I%3D
    • Vogl TJ, Bergman C, Villringer A, Einhaup K, Lissner J, Felix R (1994) Dural sinus thrombosis: Value of venous MR angiography for diagnosis and follow-up. Am J Roentgenol 162:1191-1198 1:STN:280:ByuB3Mbjt1I%3D
    • (1994) Am. J. Roentgenol. , vol.162 , pp. 1191-1198
    • Vogl, T.J.1    Bergman, C.2    Villringer, A.3    Einhaup, K.4    Lissner, J.5    Felix, R.6
  • 58
    • 0031596976 scopus 로고    scopus 로고
    • Dural arteriovenous fistula: A pitfall of time-of-flight MR venography for the diagnosis of sinus thrombosis
    • 10.1007/s002340050575
    • Kallmes DF, Cloft HJ, Jensen ME, Kaptain GJ, Dion JE, Matsumoto JA (1998) Dural arteriovenous fistula: A pitfall of time-of-flight MR venography for the diagnosis of sinus thrombosis. Neuroradiology 40:242-244 10.1007/s002340050575
    • (1998) Neuroradiology , vol.40 , pp. 242-244
    • Kallmes, D.F.1    Cloft, H.J.2    Jensen, M.E.3    Kaptain, G.J.4    Dion, J.E.5    Matsumoto, J.A.6
  • 59
    • 0035109172 scopus 로고    scopus 로고
    • Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: Prospective comparison with 2D-TOF MR venography and digital subtraction angiography
    • 1:STN:280:DC%2BD3MzjvFSrsg%3D%3D
    • Liang L, Korogi Y, Sugahara T, Onomichi M, Shigematsu Y, Yanga D, Kitajimaa M, Hiaia Y, Takahashia M (2001) Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: Prospective comparison with 2D-TOF MR venography and digital subtraction angiography. Am J Neuroradiol 22:481-492 1:STN:280:DC%2BD3MzjvFSrsg%3D%3D
    • (2001) Am. J. Neuroradiol. , vol.22 , pp. 481-492
    • Liang, L.1    Korogi, Y.2    Sugahara, T.3    Onomichi, M.4    Shigematsu, Y.5    Yanga, D.6    Kitajimaa, M.7    Hiaia, Y.8    Takahashia, M.9
  • 60
    • 0029070959 scopus 로고
    • Gadolinium-enhanced MR of chronic dural sinus thrombosis
    • 1:STN:280:ByqH3cjltFI%3D
    • Dormont L, Sag K, Biondi A, Wechsler B, Marsault C (1995) Gadolinium-enhanced MR of chronic dural sinus thrombosis. Am J Neuroradiol 16:1347-1352 1:STN:280:ByqH3cjltFI%3D
    • (1995) Am. J. Neuroradiol. , vol.16 , pp. 1347-1352
    • Dormont, L.1    Sag, K.2    Biondi, A.3    Wechsler, B.4    Marsault, C.5
  • 61
    • 0028835810 scopus 로고
    • Magnetic resonance angiography of supratentorial tumors: Comparison with selective digital subtraction angiography
    • 1:STN:280:ByqB38zksFM%3D
    • Wilms G, Bosmans H, Marchal G, Demaerel P, Goffin J, Plets C, Baert AL (1995) Magnetic resonance angiography of supratentorial tumors: comparison with selective digital subtraction angiography. Neuroradiology 37:42-47 1:STN:280:ByqB38zksFM%3D
    • (1995) Neuroradiology , vol.37 , pp. 42-47
    • Wilms, G.1    Bosmans, H.2    Marchal, G.3    Demaerel, P.4    Goffin, J.5    Plets, C.6    Baert, A.L.7
  • 62
    • 0033499705 scopus 로고    scopus 로고
    • CNS vasculitis in autoimmune disease: MR imaging findings and correlation with angiography
    • 1:STN:280:DyaK1M7jvFKnsg%3D%3D
    • Pomper MG, Miller TJ, Stone JH, Tidmore WC, Hellmann DB (1999) CNS vasculitis in autoimmune disease: MR imaging findings and correlation with angiography. Am J Neuroradiol 20:75-85 1:STN:280:DyaK1M7jvFKnsg%3D%3D
    • (1999) Am. J. Neuroradiol. , vol.20 , pp. 75-85
    • Pomper, M.G.1    Miller, T.J.2    Stone, J.H.3    Tidmore, W.C.4    Hellmann, D.B.5
  • 63
    • 0028948261 scopus 로고
    • Limitations of invasive modalities in the diagnosis of primary angiitis of the central nervous system
    • 1:STN:280:ByqA3M7isFE%3D
    • Duna GF, Calabrese LH (1995) Limitations of invasive modalities in the diagnosis of primary angiitis of the central nervous system. J Rheumatol 22:662-667 1:STN:280:ByqA3M7isFE%3D
    • (1995) J. Rheumatol. , vol.22 , pp. 662-667
    • Duna, G.F.1    Calabrese, L.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.