Volumn 3216, Issue PART 1, 2004, Pages 78-86

Correcting nonuniformities in MRI intensities using entropy minimization based on an elastic model

Author keywords

Elastic Deformation; Entropy; Expectation Maximization (EM); Partial Differential Equation

Indexed keywords

DEFORMATION; ELASTICITY; ENTROPY; IMAGE ANALYSIS; IMAGE SEGMENTATION; MAGNETIC FIELDS; PARTIAL DIFFERENTIAL EQUATIONS; SIGNAL TO NOISE RATIO; DIFFERENTIAL EQUATIONS; ELASTIC DEFORMATION; ESTIMATION; MAGNETIC RESONANCE IMAGING; MAXIMUM PRINCIPLE; PIXELS;

EID: 20344403298     PISSN: 03029743     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-30135-6_10     Document Type: Conference Paper
Times cited : (12)

References (14)
  • 1
    • 22844456092 scopus 로고    scopus 로고
    • A modified fuzzy C-means algorithm for MRI bias field estimation and adaptive segmentation
    • Ahmed, M., Yamany, S., Mohamed, N., and Farag, A. (1999). A modified fuzzy C-means algorithm for MRI bias field estimation and adaptive segmentation. MIC-CAI, pages 72-81.
    • (1999) MIC-CAI , pp. 72-81
    • Ahmed, M.1    Yamany, S.2    Mohamed, N.3    Farag, A.4
  • 3
    • 0033853121 scopus 로고    scopus 로고
    • Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging
    • Cohen, M., DuBois, R., and Zeineh, M. (2000). Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging. Human Brain Mapping, 10:204-211.
    • (2000) Human Brain Mapping , vol.10 , pp. 204-211
    • Cohen, M.1    DuBois, R.2    Zeineh, M.3
  • 4
    • 0030045341 scopus 로고    scopus 로고
    • A computerized method for morphological analysis of the corpus callosum
    • Davatzikos, C. et al. (1996). A computerized method for morphological analysis of the corpus callosum. J. Comp. Assis. Tomo., 20:88-97.
    • (1996) J. Comp. Assis. Tomo. , vol.20 , pp. 88-97
    • Davatzikos, C.1
  • 7
    • 0022995961 scopus 로고
    • Phase and sensitivity of receiver coils in magnetic resonance imaging
    • McVeigh, E., Bronskill, M., and Henkelman, R. (1986). Phase and sensitivity of receiver coils in magnetic resonance imaging. Med. Phys., 13:806-814.
    • (1986) Med. Phys. , vol.13 , pp. 806-814
    • McVeigh, E.1    Bronskill, M.2    Henkelman, R.3
  • 10
    • 84958175097 scopus 로고    scopus 로고
    • Maximum likelihood estimation of the bias field in mr brain images: Investigating different modelings of the imaging process
    • LNCS
    • Prima, S., Ayache, N., Barrick, T., and Roberts, N. (2001). Maximum likelihood estimation of the bias field in mr brain images: Investigating different modelings of the imaging process. Medical Image Computing and Computer-Assisted Intervention (MICCAI'01), LNCS 2208:811-819.
    • (2001) Medical Image Computing and Computer-Assisted Intervention (MICCAI'01) , vol.2208 , pp. 811-819
    • Prima, S.1    Ayache, N.2    Barrick, T.3    Roberts, N.4
  • 11
    • 0028339167 scopus 로고
    • Sources of intensity nonuniformity in spin echo images
    • Simmons, A., Tofts, P., Barker, G., and Arridge, S. (1994). Sources of intensity nonuniformity in spin echo images. Magn. Reson. Med., 32:121-128.
    • (1994) Magn. Reson. Med. , vol.32 , pp. 121-128
    • Simmons, A.1    Tofts, P.2    Barker, G.3    Arridge, S.4
  • 12
    • 0031987382 scopus 로고    scopus 로고
    • A nonparametric method for automatic correction of intensity nonuniformity in MRI data
    • Sled, G., Zijdenbos, A., and Evans, A. (1998). A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Trans. of Medical Imaging, 17(1):87-97.
    • (1998) IEEE Trans. of Medical Imaging , vol.17 , Issue.1 , pp. 87-97
    • Sled, G.1    Zijdenbos, A.2    Evans, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.