메뉴 건너뛰기




Volumn 12, Issue 3, 2005, Pages 261-267

High-resolution molecular imaging techniques for cardiovascular research

Author keywords

[No Author keywords available]

Indexed keywords

BISMUTH; GERMANIUM; LUTETIUM; TRACER;

EID: 20344400361     PISSN: 10713581     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nuclcard.2005.03.005     Document Type: Editorial
Times cited : (9)

References (18)
  • 1
    • 0002881819 scopus 로고    scopus 로고
    • Volume imaging tomographs
    • B. Bendriem D.W. Townsend, editors Kluwer Academic Publishers Dordrecht, Netherlands
    • D.W. Townsend R.A. Isoardi B. Bendriem Volume imaging tomographs In: B. Bendriem D.W. Townsend, editors The theory and practice of 3D PET 1998 Kluwer Academic Publishers Dordrecht, Netherlands
    • (1998) The Theory and Practice of 3D PET
    • Townsend, D.W.1    Isoardi, R.A.2    Bendriem, B.3
  • 2
    • 0036464422 scopus 로고    scopus 로고
    • The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph
    • K. Wienhard M. Schmand M.E. Casey K. Baker J. Bao L. Eriksson et al. The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph IEEE Trans Nucl Sci 49 2002 104-110
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 104-110
    • Wienhard, K.1    Schmand, M.2    Casey, M.E.3    Baker, K.4    Bao, J.5    Eriksson, L.6
  • 4
    • 1142263259 scopus 로고    scopus 로고
    • In vivo molecular and genomic imaging imaging: New challenges for imaging physics
    • S.R. Cherry In vivo molecular and genomic imaging: New challenges for imaging physics Phys Med Biol 49 2004 R13-R48
    • (2004) Phys. Med. Biol. , vol.49
    • Cherry, S.R.1
  • 6
    • 2942724677 scopus 로고    scopus 로고
    • Technology challenges in small animal PET imaging
    • R. Lecomte Technology challenges in small animal PET imaging Nucl Instrum Methods Phys Res A 527 2004 157-165
    • (2004) Nucl. Instrum. Methods Phys. Res. A , vol.527 , pp. 157-165
    • Lecomte, R.1
  • 7
    • 0142063381 scopus 로고    scopus 로고
    • Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanners without depth-of-interaction capability
    • J. Seidel J.J. Vaquero M.V. Green Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanners without depth-of-interaction capability IEEE Trans Nucl Sci 50 2003 1347-1350
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 1347-1350
    • Seidel, J.1    Vaquero, J.J.2    Green, M.V.3
  • 9
    • 0031981253 scopus 로고    scopus 로고
    • High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
    • J.Y. Qi R.M. Leahy S.R. Cherry A. Chatziioannou T.H. Farquhar High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner Phys Med Biol 43 1998 1001-1013
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1001-1013
    • Qi, J.Y.1    Leahy, R.M.2    Cherry, S.R.3    Chatziioannou, A.4    Farquhar, T.H.5
  • 11
    • 3242789549 scopus 로고    scopus 로고
    • Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging
    • Y.F. Yang Y.C. Tai S. Siegel D.F. Newport B. Bai Q.Z. Li et al. Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging Phys Med Biol 49 2004 2527-2545
    • (2004) Phys. Med. Biol. , vol.49 , pp. 2527-2545
    • Yang, Y.F.1    Tai, Y.C.2    Siegel, S.3    Newport, D.F.4    Bai, B.5    Li, Q.Z.6
  • 12
    • 5744242293 scopus 로고    scopus 로고
    • Design and simulation of a high-resolution stationary SPECT system for small animals
    • F.J. Beekman B. Vastenhouw Design and simulation of a high-resolution stationary SPECT system for small animals Phys Med Biol 49 2004 4579-4592
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4579-4592
    • Beekman, F.J.1    Vastenhouw, B.2
  • 14
    • 0036917451 scopus 로고    scopus 로고
    • Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice
    • M.C. Wu B.H. Hasegawa M.W. Dae Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice Med Phys 29 2002 2830-2839
    • (2002) Med. Phys. , vol.29 , pp. 2830-2839
    • Wu, M.C.1    Hasegawa, B.H.2    Dae, M.W.3
  • 15
    • 20344392945 scopus 로고    scopus 로고
    • Feasibility of microSPECT/CT imaging of plaques in a transgenic mouse model
    • M.A. Kupinski H.H. Barrett, editors Springer Science & Business Media New York in press
    • B.M.W. Tsui Y. Wang Y. Qi S. Sawyer E.C. Frey S. Majewski Feasibility of microSPECT/CT imaging of plaques in a transgenic mouse model In: M.A. Kupinski H.H. Barrett, editors Small animal SPECT imaging 29 2005 Springer Science & Business Media New York in press
    • (2005) Small Animal SPECT Imaging , vol.29
    • Tsui, B.M.W.1    Wang, Y.2    Qi, Y.3    Sawyer, S.4    Frey, E.C.5    Majewski, S.6
  • 16
    • 20344406039 scopus 로고    scopus 로고
    • Development and characterization of a high-resolution microSPECT system for small animal imaging
    • M.A. Kupinski H.H. Barrett, editors Springer Business & Science Media New York in press
    • Y. Qi B.M.W. Tsui Y. Wang B. Yoder R. Wojcik S. Majewski Development and characterization of a high-resolution microSPECT system for small animal imaging. In: M.A. Kupinski H.H. Barrett, editors Small animal SPECT imaging 29 2005 Springer Business & Science Media New York in press
    • (2005) Small Animal SPECT Imaging , vol.29
    • Qi, Y.1    Tsui, B.M.W.2    Wang, Y.3    Yoder, B.4    Wojcik, R.5    Majewski, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.