메뉴 건너뛰기




Volumn 11, Issue 2 SPEC. ISS., 2005, Pages 265-280

Expiratory asynchrony

Author keywords

[No Author keywords available]

Indexed keywords

AIRWAY PRESSURE; AIRWAY RESISTANCE; ALGORITHM; ARTIFICIAL VENTILATION; AUTOMATION; BAROTRAUMA; BRAIN ISCHEMIA; BREATHING MECHANICS; BREATHING MUSCLE; CHRONIC OBSTRUCTIVE LUNG DISEASE; COMPUTER MODEL; CONTROL SYSTEM; ELECTROMYOGRAM; ENDOTRACHEAL TUBE; HUMAN; INTENSIVE CARE UNIT; INTERMITTENT MANDATORY VENTILATION; LUNG COMPLIANCE; LUNG FUNCTION TEST; LUNG INFLATION; MATHEMATICAL MODEL; NERVE CONDUCTION; PNEUMOTHORAX; POSITIVE END EXPIRATORY PRESSURE; RESPIRATION CONTROL; RESPIRATORY AIRFLOW; REVIEW; SENSITIVITY ANALYSIS; SIMULATION; VENTILATOR;

EID: 20344391905     PISSN: 10785337     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rcc.2005.02.001     Document Type: Review
Times cited : (16)

References (30)
  • 1
    • 0031788771 scopus 로고    scopus 로고
    • Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation
    • S. Parthasarathy A. Jubran M.J. Tobin Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation Am J Respir Crit Care Med 158 1998 1471-1478
    • (1998) Am. J. Respir. Crit. Care Med. , vol.158 , pp. 1471-1478
    • Parthasarathy, S.1    Jubran, A.2    Tobin, M.J.3
  • 2
    • 0029121830 scopus 로고
    • Variability of patient-ventilator interaction with pressure support ventilation in patients with chronic obstructive pulmonary disease
    • A. Jubran W.B. Van de Graaff M.J. Tobin Variability of patient-ventilator interaction with pressure support ventilation in patients with chronic obstructive pulmonary disease Am J Respir Crit Care Med 152 1995 129-136
    • (1995) Am. J. Respir. Crit. Care Med. , vol.152 , pp. 129-136
    • Jubran, A.1    Van de Graaff, W.B.2    Tobin, M.J.3
  • 3
    • 0021333670 scopus 로고
    • Pancuronium prevents pneumothoraces in ventilated premature babies who actively expire against positive pressure ventilation
    • A. Greenough S. Wood C.J. Morley et al. Pancuronium prevents pneumothoraces in ventilated premature babies who actively expire against positive pressure ventilation Lancet 1 1984 1-13
    • (1984) Lancet , vol.1 , pp. 1-13
    • Greenough, A.1    Wood, S.2    Morley, C.J.3
  • 4
    • 0019382378 scopus 로고
    • Pneumothorax and cerebral haemorrhage in preterm infants
    • A.P. Lipscomb R.J. Thorburn E.O. Reynolds et al. Pneumothorax and cerebral haemorrhage in preterm infants Lancet 1 1981 414-416
    • (1981) Lancet , vol.1 , pp. 414-416
    • Lipscomb, A.P.1    Thorburn, R.J.2    Reynolds, E.O.3
  • 5
    • 0031033608 scopus 로고    scopus 로고
    • Patient-ventilator interaction and inspiratory effort during pressure support ventilation in patients with different pathologies
    • S. Nava C. Bruschi C. Fracchia et al. Patient-ventilator interaction and inspiratory effort during pressure support ventilation in patients with different pathologies Eur Respir J 10 1997 177-183
    • (1997) Eur. Respir. J , vol.10 , pp. 177-183
    • Nava, S.1    Bruschi, C.2    Fracchia, C.3
  • 6
    • 0036644463 scopus 로고    scopus 로고
    • Response of ventilator-dependent patients to delayed opening of exhalation valve
    • M. Younes J. Kun K. Webster et al. Response of ventilator-dependent patients to delayed opening of exhalation valve Am J Respir Crit Care Med 166 2002 21-30
    • (2002) Am. J. Respir. Crit. Care Med. , vol.166 , pp. 21-30
    • Younes, M.1    Kun, J.2    Webster, K.3
  • 7
    • 0026040175 scopus 로고
    • Pressure support: Changes in ventilatory pattern and components of the work of breathing
    • W.B. Van de Graaff K. Gordey S.E. Dornseif et al. Pressure support: changes in ventilatory pattern and components of the work of breathing Chest 100 1991 1082-1089
    • (1991) Chest , vol.100 , pp. 1082-1089
    • Van de Graaff, W.B.1    Gordey, K.2    Dornseif, S.E.3
  • 8
    • 0028825504 scopus 로고
    • Interrelationship of breath components in neighboring breaths of normal eupneic subjects
    • M.J. Tobin K.L. Yang A. Jubran et al. Interrelationship of breath components in neighboring breaths of normal eupneic subjects Am J Respir Crit Care Med 152 1995 1967-1976
    • (1995) Am. J. Respir. Crit. Care Med. , vol.152 , pp. 1967-1976
    • Tobin, M.J.1    Yang, K.L.2    Jubran, A.3
  • 9
    • 0033933102 scopus 로고    scopus 로고
    • Analysis of the mechanisms of expiratory asynchrony in pressure support ventilation: A mathematical approach
    • Y. Yamada H.L. Du Analysis of the mechanisms of expiratory asynchrony in pressure support ventilation: A mathematical approach J Appl Physiol 88 2000 2143-2150
    • (2000) J. Appl. Physiol. , vol.88 , pp. 2143-2150
    • Yamada, Y.1    Du, H.L.2
  • 10
    • 0032469807 scopus 로고    scopus 로고
    • Pressure support ventilation, patient-ventilator synchrony, and ventilator algorithm
    • [editorial]
    • R.D. Branson R.S. Campbell Pressure support ventilation, patient-ventilator synchrony, and ventilator algorithm [editorial] Respir Care 43 1998 1045-1047
    • (1998) Respir. Care , vol.43 , pp. 1045-1047
    • Branson, R.D.1    Campbell, R.S.2
  • 11
    • 0032766123 scopus 로고    scopus 로고
    • NIPPV: Patient-ventilator synchrony, the difference between success and failure?
    • R.M. Kacmarek NIPPV: Patient-ventilator synchrony, the difference between success and failure? Intensive Care Med 25 1999 645-647
    • (1999) Intensive Care Med. , vol.25 , pp. 645-647
    • Kacmarek, R.M.1
  • 12
    • 0035726861 scopus 로고    scopus 로고
    • Automation of expiratory trigger sensitivity in pressure support ventilation
    • H.L. Du M.B.P. Amato Y. Yamada Automation of expiratory trigger sensitivity in pressure support ventilation Respir Care Clin North Am 7 2001 503-517
    • (2001) Respir. Care Clin. North Am. , vol.7 , pp. 503-517
    • Du, H.L.1    Amato, M.B.P.2    Yamada, Y.3
  • 13
    • 0026508795 scopus 로고
    • Proportional assist ventilation: A new approach to ventilatory support
    • M. Younes Proportional assist ventilation: A new approach to ventilatory support Am Rev Respir Dis 145 1992 114-120
    • (1992) Am. Rev. Respir. Dis. , vol.145 , pp. 114-120
    • Younes, M.1
  • 14
    • 0026526711 scopus 로고
    • Proportional assist ventilation: Results of an initial clinical trial
    • M. Younes A. Puddy D. Roberts et al. Proportional assist ventilation: results of an initial clinical trial Am Rev Respir Dis 145 1992 121-129
    • (1992) Am. Rev. Respir. Dis. , vol.145 , pp. 121-129
    • Younes, M.1    Puddy, A.2    Roberts, D.3
  • 15
    • 0032993065 scopus 로고    scopus 로고
    • Response of ventilator-dependent patients to different levels of pressure support and proportional assist
    • E. Giannouli K. Webster D. Roberts et al. Response of ventilator-dependent patients to different levels of pressure support and proportional assist Am J Respir Crit Care Med 159 1999 1716-1725
    • (1999) Am. J. Respir. Crit. Care Med. , vol.159 , pp. 1716-1725
    • Giannouli, E.1    Webster, K.2    Roberts, D.3
  • 16
    • 0342327365 scopus 로고    scopus 로고
    • Effects of proportional assist ventilation on inspiratory muscle effort in patients with chronic obstructive pulmonary disease and acute respiratory failure
    • V.M. Ranieri S. Grasso L. Mascia et al. Effects of proportional assist ventilation on inspiratory muscle effort in patients with chronic obstructive pulmonary disease and acute respiratory failure Anesthesiology 86 1997 79-91
    • (1997) Anesthesiology , vol.86 , pp. 79-91
    • Ranieri, V.M.1    Grasso, S.2    Mascia, L.3
  • 17
    • 0029798962 scopus 로고    scopus 로고
    • Proportional assist ventilation in acute respiratory failure: Effects on breathing pattern and inspiratory effort
    • P. Navalesi P. Hernandez A. Wongsa et al. Proportional assist ventilation in acute respiratory failure: Effects on breathing pattern and inspiratory effort Am J Respir Crit Care Med 154 1996 1330-1338
    • (1996) Am. J. Respir. Crit. Care Med. , vol.154 , pp. 1330-1338
    • Navalesi, P.1    Hernandez, P.2    Wongsa, A.3
  • 19
    • 0035060443 scopus 로고    scopus 로고
    • A method for noninvasive determination of inspiratory resistance during proportional assist ventilation
    • M. Younes J. Kun B. Masiowski et al. A method for noninvasive determination of inspiratory resistance during proportional assist ventilation Am J Respir Crit Care Med 163 2001 829-839
    • (2001) Am. J. Respir. Crit. Care Med. , vol.163 , pp. 829-839
    • Younes, M.1    Kun, J.2    Masiowski, B.3
  • 20
    • 0035402251 scopus 로고    scopus 로고
    • A method for measuring passive elastance during proportional assist ventilation
    • M. Younes K. Webster J. Kun et al. A method for measuring passive elastance during proportional assist ventilation Am J Respir Crit Care Med 164 2001 50-60
    • (2001) Am. J. Respir. Crit. Care Med. , vol.164 , pp. 50-60
    • Younes, M.1    Webster, K.2    Kun, J.3
  • 21
    • 0035447004 scopus 로고    scopus 로고
    • Oscillatory resistance measured during noninvasive proportional assist ventilation
    • R. Farre M. Mancini M. Rotger et al. Oscillatory resistance measured during noninvasive proportional assist ventilation Am J Respir Crit Care Med 164 2001 790-794
    • (2001) Am. J. Respir. Crit. Care Med. , vol.164 , pp. 790-794
    • Farre, R.1    Mancini, M.2    Rotger, M.3
  • 22
    • 0035209852 scopus 로고    scopus 로고
    • The influence of endotracheal tube leak on the assessment of respiratory function in ventilated children
    • E. Main R. Castle J. Stocks et al. The influence of endotracheal tube leak on the assessment of respiratory function in ventilated children Intensive Care Med 27 2001 1788-1797
    • (2001) Intensive Care Med. , vol.27 , pp. 1788-1797
    • Main, E.1    Castle, R.2    Stocks, J.3
  • 24
    • 0023223282 scopus 로고
    • An apparatus for altering the mechanical load of the respiratory system
    • M. Younes D. Bilan D. Jung et al. An apparatus for altering the mechanical load of the respiratory system J Appl Physiol 62 1987 2491-2499
    • (1987) J. Appl. Physiol. , vol.62 , pp. 2491-2499
    • Younes, M.1    Bilan, D.2    Jung, D.3
  • 25
    • 0027323905 scopus 로고
    • Patient-ventilator interaction with pressure-assisted modalities of ventilatory support
    • M. Younes Patient-ventilator interaction with pressure-assisted modalities of ventilatory support Semin Respir Med 14 1993 299-322
    • (1993) Semin. Respir. Med. , vol.14 , pp. 299-322
    • Younes, M.1
  • 26
    • 1942501826 scopus 로고    scopus 로고
    • Prolonged neural expiratory time induced by mechanical ventilation in infants
    • J. Beck M. Tucci G. Emeriaud et al. Prolonged neural expiratory time induced by mechanical ventilation in infants Pediatr Res 55 2004 1-8
    • (2004) Pediatr. Res. , vol.55 , pp. 1-8
    • Beck, J.1    Tucci, M.2    Emeriaud, G.3
  • 27
    • 0028824792 scopus 로고
    • Airway leak size in neonates and autocycling of three flow-triggered ventilators
    • G. Bernstein E. Knodel G. Heldt Airway leak size in neonates and autocycling of three flow-triggered ventilators Crit Care Med 23 1995 1739-1744
    • (1995) Crit. Care Med. , vol.23 , pp. 1739-1744
    • Bernstein, G.1    Knodel, E.2    Heldt, G.3
  • 29
    • 0003175498 scopus 로고
    • Relationship between neuromuscular respiratory drive and ventilatory output
    • A.P. Fishman editor. American Physiological Society Bethesda (MD)
    • J. Milic-Emili W.A. Zin Relationship between neuromuscular respiratory drive and ventilatory output In: A.P. Fishman editor. Handbook of physiology. Section 3: The respiratory system vol. III 1986 American Physiological Society Bethesda (MD) 631-646
    • (1986) Handbook of Physiology. Section 3: The Respiratory System , vol.3 , pp. 631-646
    • Milic-Emili, J.1    Zin, W.A.2
  • 30
    • 0014265382 scopus 로고
    • Dynamics of the maximal contraction of the respiratory muscles
    • P. Mognoni F. Saibene G. Sant'Ambrogio et al. Dynamics of the maximal contraction of the respiratory muscles Respir Physiol 4 1963 193-202
    • (1963) Respir. Physiol. , vol.4 , pp. 193-202
    • Mognoni, P.1    Saibene, F.2    Sant'Ambrogio, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.