메뉴 건너뛰기




Volumn 3216, Issue PART 1, 2004, Pages 508-515

Accurate quantification of small-diameter tubular structures in isotropic CT volume data based on multiscale line filter responses

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; BLOOD VESSELS; COMPUTER AIDED DIAGNOSIS; DATA ACQUISITION; IMAGE ANALYSIS; MEDICAL IMAGING; SCANNING; CURVE FITTING; EDGE DETECTION; OPTICAL TRANSFER FUNCTION;

EID: 20344379673     PISSN: 03029743     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-30135-6_62     Document Type: Conference Paper
Times cited : (14)

References (11)
  • 1
    • 0033201371 scopus 로고    scopus 로고
    • Model-based quantitation of 3-D magnetic resonance angiographic images
    • Frangi AF, Niessen WJ, Hoogeveen RM, et al.: Model-based quantitation of 3-D magnetic resonance angiographic images, IEEE Trans Med Imaging, 18(10):946-956, 1999.
    • (1999) IEEE Trans Med Imaging , vol.18 , Issue.10 , pp. 946-956
    • Frangi, A.F.1    Niessen, W.J.2    Hoogeveen, R.M.3
  • 2
    • 0034164341 scopus 로고    scopus 로고
    • Fast delineation and visualization of vessels in 3-D angiographic images
    • Wink O, Niessen WJ, Viergever MA: Fast delineation and visualization of vessels in 3-D angiographic images, IEEE Trans Med Imaging, 19(4):337-346, 2000.
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.4 , pp. 337-346
    • Wink, O.1    Niessen, W.J.2    Viergever, M.A.3
  • 4
    • 0031784731 scopus 로고    scopus 로고
    • Limits to the accuracy of vessel diameter measurement in MR angiography
    • Hoogeveen RM, Bakker CJG, Viergever MA: Limits to the accuracy of vessel diameter measurement in MR angiography, JMRI - J Magn Reson Imaging, 8(6): 1228-1235, 1998.
    • (1998) JMRI - J Magn Reson Imaging , vol.8 , Issue.6 , pp. 1228-1235
    • Hoogeveen, R.M.1    Bakker, C.J.G.2    Viergever, M.A.3
  • 5
    • 0032998150 scopus 로고    scopus 로고
    • Accuracy limits for the determination of cortical width and density: The influence of object size and CT imaging parameters
    • Prevrhal S, Engelke K, Kalender WA: Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters, Phys Med Biol, 44(3):751-764, 1999.
    • (1999) Phys Med Biol , vol.44 , Issue.3 , pp. 751-764
    • Prevrhal, S.1    Engelke, K.2    Kalender, W.A.3
  • 6
    • 0032781830 scopus 로고    scopus 로고
    • Measurement of thickness and density of thin structures by computed tomography: A simulation study
    • Dougherty G and Newman DL: Measurement of thickness and density of thin structures by computed tomography: A simulation study, Med Phys, 25(7):1341-1348, 1999.
    • (1999) Med Phys , vol.25 , Issue.7 , pp. 1341-1348
    • Dougherty, G.1    Newman, D.L.2
  • 7
    • 0141745582 scopus 로고    scopus 로고
    • Limits on the accuracy of 3D thickness measurement in magnetic resonance images - Effects of voxel anisotropy
    • Sato Y, Tanaka H, Nishii T, et al.: Limits on the accuracy of 3D thickness measurement in magnetic resonance images - Effects of voxel anisotropy, IEEE Trans Med Imaging, 22(9):1076-1088, 2003.
    • (2003) IEEE Trans Med Imaging , vol.22 , Issue.9 , pp. 1076-1088
    • Sato, Y.1    Tanaka, H.2    Nishii, T.3
  • 9
    • 0032081365 scopus 로고    scopus 로고
    • Three dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images
    • Sato Y, Nakajima S, Shiraga N, et al.: Three dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images, Med Image Anal, 2(2):143-168, 1998.
    • (1998) Med Image Anal , vol.2 , Issue.2 , pp. 143-168
    • Sato, Y.1    Nakajima, S.2    Shiraga, N.3
  • 10
    • 0034321042 scopus 로고    scopus 로고
    • Model-based detection of tubular structures in 3D images
    • Krissian K, Malandain G, Ayache, N, et al.: Model-based detection of tubular structures in 3D images, Comput Vis Image Und, 80(2):130-171, 2000.
    • (2000) Comput Vis Image und , vol.80 , Issue.2 , pp. 130-171
    • Krissian, K.1    Malandain, G.2    Ayache, N.3
  • 11
    • 0036462551 scopus 로고    scopus 로고
    • Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction
    • Aylward SR, Bullitt E: Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction, IEEE Trans Med Imaging, 21(2):61-75, 2002.
    • (2002) IEEE Trans Med Imaging , vol.21 , Issue.2 , pp. 61-75
    • Aylward, S.R.1    Bullitt, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.