메뉴 건너뛰기




Volumn 26, Issue 7, 1999, Pages 1341-1348

Measurement of thickness and density of thin structures by computed tomography: A simulation study

Author keywords

Digital convolution; Quantitative computed tomography; Spatial resolution; Vertebral strength

Indexed keywords

BONE; GAUSSIAN DISTRIBUTION; IMAGE RESOLUTION; OPTICAL TRANSFER FUNCTION; SHELLS (STRUCTURES); THICKNESS MEASUREMENT;

EID: 0032781830     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598629     Document Type: Article
Times cited : (74)

References (24)
  • 1
    • 0014463475 scopus 로고
    • The relative contribution of trabecular and cortical bone to the strength of human lumbar vertebrae
    • S. D. Rockoff, E. Sweet, and J. Bleustein, "The relative contribution of trabecular and cortical bone to the strength of human lumbar vertebrae," Calcif. Tissue Int. 3, 163-175 (1969).
    • (1969) Calcif. Tissue Int. , vol.3 , pp. 163-175
    • Rockoff, S.D.1    Sweet, E.2    Bleustein, J.3
  • 2
    • 0022997529 scopus 로고
    • Normal vertebral body size and compressive strength: Relation to age and to vertebral and iliac trabecular bone compressive strength
    • L. Mosekilde and L. Mosekilde, "Normal vertebral body size and compressive strength: Relation to age and to vertebral and iliac trabecular bone compressive strength," Bone 7, 207-212 (1986).
    • (1986) Bone , vol.7 , pp. 207-212
    • Mosekilde, L.1    Mosekilde, L.2
  • 3
    • 0025160557 scopus 로고
    • Fracture risk: A role for compact bone
    • R. B. Mazess, "Fracture risk: A role for compact bone," Calcif. Tissue Int. 47, 191-193 (1990).
    • (1990) Calcif. Tissue Int. , vol.47 , pp. 191-193
    • Mazess, R.B.1
  • 4
    • 0025730179 scopus 로고
    • Effect of bone distribution in vertebral strength assessment with patient-specific non-linear finite element analysis
    • K. G. Faulkner, C. E. Cann, and B. H. Hasegawa, "Effect of bone distribution in vertebral strength assessment with patient-specific non-linear finite element analysis," Radiology 179, 669-674 (1991).
    • (1991) Radiology , vol.179 , pp. 669-674
    • Faulkner, K.G.1    Cann, C.E.2    Hasegawa, B.H.3
  • 6
    • 0027244901 scopus 로고
    • The assessment of vertebral bone macroarchitecture with x-ray computed tomography
    • M. J. Flynn and D. D. Cody, "The assessment of vertebral bone macroarchitecture with x-ray computed tomography," Calcif. Tissue Int. 53, S170-S175 (1993).
    • (1993) Calcif. Tissue Int. , vol.53
    • Flynn, M.J.1    Cody, D.D.2
  • 7
    • 0027872371 scopus 로고
    • Size of cortical bone and relationship to bone mineral density assessed by quantitative computed tomography image segmentation
    • O. Louis, P. Van den Winkel, P. Covens, A. Schoutens, and M. Osteaux, "Size of cortical bone and relationship to bone mineral density assessed by quantitative computed tomography image segmentation," Invest. Radiol. 28, 802-805 (1993).
    • (1993) Invest. Radiol. , vol.28 , pp. 802-805
    • Louis, O.1    Van Den Winkel, P.2    Covens, P.3    Schoutens, A.4    Osteaux, M.5
  • 8
    • 0028229885 scopus 로고
    • Direct and computed tomography thickness measurements of the human lumbar vertebral shell and endplate
    • M. J. Silva, C. Wang, T. M. Keaveny, and W. C. Hayes, "Direct and computed tomography thickness measurements of the human lumbar vertebral shell and endplate," Bone 15, 409-414 (1994).
    • (1994) Bone , vol.15 , pp. 409-414
    • Silva, M.J.1    Wang, C.2    Keaveny, T.M.3    Hayes, W.C.4
  • 9
    • 0028789562 scopus 로고
    • Cortical thickness assesses by peripheral quantitative computed tomography: Accuracy evaluated on radius specimens
    • O. Louis, J. Willnecker, S. Soykens, P. Van den Winkel, and M. Ostreaux, "Cortical thickness assesses by peripheral quantitative computed tomography: Accuracy evaluated on radius specimens," Osteoporosis Int. 5, 446-449 (1995).
    • (1995) Osteoporosis Int. , vol.5 , pp. 446-449
    • Louis, O.1    Willnecker, J.2    Soykens, S.3    Van Den Winkel, P.4    Ostreaux, M.5
  • 10
    • 0023552633 scopus 로고
    • Performance evaluation of density measurements of axial and peripheral bone with x-ray and gamma-ray computed tomography
    • T. N. Hangartner, J. J. Battista, and T. R. Overton, "Performance evaluation of density measurements of axial and peripheral bone with x-ray and gamma-ray computed tomography," Phys. Med. Biol. 32, 1393-1406 (1987).
    • (1987) Phys. Med. Biol. , vol.32 , pp. 1393-1406
    • Hangartner, T.N.1    Battista, J.J.2    Overton, T.R.3
  • 11
    • 0029782287 scopus 로고    scopus 로고
    • Evaluation of cortical bone by computed tomography
    • T. N. Hangartner and V. Gilsanz, "Evaluation of cortical bone by computed tomography," J. Bone Mineral Res. 11, 1518-1525 (1996).
    • (1996) J. Bone Mineral Res. , vol.11 , pp. 1518-1525
    • Hangartner, T.N.1    Gilsanz, V.2
  • 12
    • 0031929482 scopus 로고    scopus 로고
    • Limitations of clinical CT in assessing cortical thickness and density
    • D. L. Newman, G. Dougherty, A. Al Obaid, and H. Al Hijrasy, "Limitations of clinical CT in assessing cortical thickness and density," Phys. Med. Biol. 43, 619-626 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 619-626
    • Newman, D.L.1    Dougherty, G.2    Al Obaid, A.3    Al Hijrasy, H.4
  • 13
    • 0015116113 scopus 로고
    • Three-dimensional reconstruction from radiographs and electron micrographs: Application of convolutions instead of Fourier transforms
    • G. N. Ramachandran and A. V. Lakshminarayanan, "Three-dimensional reconstruction from radiographs and electron micrographs: Application of convolutions instead of Fourier transforms," Proc. Natl. Acad. Sci. USA 68, 2236-2240 (1971).
    • (1971) Proc. Natl. Acad. Sci. USA , vol.68 , pp. 2236-2240
    • Ramachandran, G.N.1    Lakshminarayanan, A.V.2
  • 14
    • 0016068330 scopus 로고
    • The Fourier reconstruction of a head section
    • L. A. Shepp and B. F. Logan, "The Fourier reconstruction of a head section," IEEE Trans. Nucl. Sci. NS-21, 21-43 (1974).
    • (1974) IEEE Trans. Nucl. Sci. , vol.NS-21 , pp. 21-43
    • Shepp, L.A.1    Logan, B.F.2
  • 15
    • 0342997827 scopus 로고
    • Spatial resolution in computed tomography
    • edited by T. H. Newton and D. G. Potts Mosby, St. Louis, MO
    • S. M. Blumenfeld and G. Glover, "Spatial resolution in computed tomography," in Radiology of the Skull: Technical Aspects of Computed Tomography, edited by T. H. Newton and D. G. Potts (Mosby, St. Louis, MO, 1981), Vol. 5, pp. 3918-3940.
    • (1981) Radiology of the Skull: Technical Aspects of Computed Tomography , vol.5 , pp. 3918-3940
    • Blumenfeld, S.M.1    Glover, G.2
  • 16
    • 0023025865 scopus 로고
    • Reduction of aliasing in modulation transfer function measurements
    • J. C. Erhardt, "Reduction of aliasing in modulation transfer function measurements," Med. Phys. 13, 658-662 (1986).
    • (1986) Med. Phys. , vol.13 , pp. 658-662
    • Erhardt, J.C.1
  • 17
    • 0021253653 scopus 로고
    • Investigation of basic imaging properties in digital radiography. I. Modulation transfer function
    • M. L. Giger and K. Doi, "Investigation of basic imaging properties in digital radiography. I. Modulation transfer function," Med. Phys. 11, 287-295 (1984).
    • (1984) Med. Phys. , vol.11 , pp. 287-295
    • Giger, M.L.1    Doi, K.2
  • 19
    • 0025108559 scopus 로고
    • Vertebral cortical bone mass measurement by a new quantitative computer tomography method: Correlations with vertebral trabecular bone measurements
    • R. Pacifici, R. C. Rupich, and L. V. Avioli, "Vertebral cortical bone mass measurement by a new quantitative computer tomography method: Correlations with vertebral trabecular bone measurements," Calcif. Tissue Int. 47, 215-220 (1990).
    • (1990) Calcif. Tissue Int. , vol.47 , pp. 215-220
    • Pacifici, R.1    Rupich, R.C.2    Avioli, L.V.3
  • 20
    • 0024348104 scopus 로고
    • Reference values for trabecular and cortical vertebral bone density in single and dual-energy quantitative computed tomography
    • W. A. Kalender, D. Felsenberg, O. Louis, P. Lopez, E. Klotz, M. Osteaux, and J. Fraga, "Reference values for trabecular and cortical vertebral bone density in single and dual-energy quantitative computed tomography," Eur. J. Radiol. 9, 75-80 (1989).
    • (1989) Eur. J. Radiol. , vol.9 , pp. 75-80
    • Kalender, W.A.1    Felsenberg, D.2    Louis, O.3    Lopez, P.4    Klotz, E.5    Osteaux, M.6    Fraga, J.7
  • 21
    • 0026102650 scopus 로고
    • Localisation of regional forearm bone loss from high resolution computed tomographic images
    • P. Ruegsegger, E. Durand, and M. A. Dambacher, "Localisation of regional forearm bone loss from high resolution computed tomographic images," Osteoporosis Int. 1, 76-80 (1991).
    • (1991) Osteoporosis Int. , vol.1 , pp. 76-80
    • Ruegsegger, P.1    Durand, E.2    Dambacher, M.A.3
  • 22
    • 33744619325 scopus 로고
    • Effect of systemic pathologic condition on bone size but not on bone density
    • L. Schneider and W. Borner, "Effect of systemic pathologic condition on bone size but not on bone density," Bone Miner. 25, 39-45 (1994).
    • (1994) Bone Miner. , vol.25 , pp. 39-45
    • Schneider, L.1    Borner, W.2
  • 23
    • 0022344346 scopus 로고
    • Prediction of vertebral body compressive fracture using computed tomography
    • R. J. McBroom, W. C. Hayes, W. T. Edwards, R. P. Goldberg, and A. A. White, "Prediction of vertebral body compressive fracture using computed tomography," J. Bone Jt. Surg. 67A, 1206-1213 (1985).
    • (1985) J. Bone Jt. Surg. , vol.67 A , pp. 1206-1213
    • McBroom, R.J.1    Hayes, W.C.2    Edwards, W.T.3    Goldberg, R.P.4    White, A.A.5
  • 24
    • 0026751874 scopus 로고
    • Compact and trabecular components of the spine using quantitative computed tomography
    • T. Sandor, D. Felsenberg, W. A. Kalender, A. Clain, and E. Brown, "Compact and trabecular components of the spine using quantitative computed tomography," Calcif. Tissue Int. 50, 502-506 (1992).
    • (1992) Calcif. Tissue Int. , vol.50 , pp. 502-506
    • Sandor, T.1    Felsenberg, D.2    Kalender, W.A.3    Clain, A.4    Brown, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.