-
2
-
-
0028852325
-
HeartMate implantable left ventricular assist device: Bridge to transplantation and future applications
-
McCarthy PM. HeartMate implantable left ventricular assist device: bridge to transplantation and future applications. Ann Thorac Surg 1995;59:S46-51.
-
(1995)
Ann Thorac Surg
, vol.59
-
-
McCarthy, P.M.1
-
3
-
-
0023370785
-
Rotary pump artificial heart: A new system for circulatory assistance or heart replacement
-
Monties JR, Havlik P, Mesana T, Trinckl J, Aucomte F, Gauthier T. Rotary pump artificial heart: a new system for circulatory assistance or heart replacement. Life Support Systems 1987;5:251-7.
-
(1987)
Life Support Systems
, vol.5
, pp. 251-257
-
-
Monties, J.R.1
Havlik, P.2
Mesana, T.3
Trinckl, J.4
Aucomte, F.5
Gauthier, T.6
-
4
-
-
84990530952
-
Ecoulements au sein d'une prothèse cardiaque hypocycloïdale sans clapet
-
Bellet D, Sengelin M, Henge JC. Ecoulements au sein d'une prothèse cardiaque hypocycloïdale sans clapet. Innovation Technol Biol Med 1986;7:3-11.
-
(1986)
Innovation Technol Biol Med
, vol.7
, pp. 3-11
-
-
Bellet, D.1
Sengelin, M.2
Henge, J.C.3
-
5
-
-
0025458341
-
Another way of pumping blood with a rotary but not centrifugal pump for an artificial heart
-
Monties JR, Mesana T, Havlik P, Trinkl J, Demunck JL, Candelon B. Another way of pumping blood with a rotary but not centrifugal pump for an artificial heart. ASAIO Trans 1990;36:M258-60.
-
(1990)
ASAIO Trans
, vol.36
-
-
Monties, J.R.1
Mesana, T.2
Havlik, P.3
Trinkl, J.4
Demunck, J.L.5
Candelon, B.6
-
6
-
-
0027551943
-
TiN coating: Surface characterization and hemocompatibility
-
Dion I, Rouais F, Trut L, Baquey C, Monties JR, Havlik P. TiN coating: surface characterization and hemocompatibility. Biomaterials 1993;14:169-76.
-
(1993)
Biomaterials
, vol.14
, pp. 169-176
-
-
Dion, I.1
Rouais, F.2
Trut, L.3
Baquey, C.4
Monties, J.R.5
Havlik, P.6
-
7
-
-
0026194190
-
First significant animal survival with a Wankeltype left ventricular assist device
-
Mesana T, Mitsui N, Tririkl J, Demunck JL, Havlik P, Monties JR. First significant animal survival with a Wankeltype left ventricular assist device. ASAIO Trans 1991;137:M166-8.
-
(1991)
ASAIO Trans
, vol.137
-
-
Mesana, T.1
Mitsui, N.2
Tririkl, J.3
Demunck, J.L.4
Havlik, P.5
Monties, J.R.6
-
8
-
-
0026192787
-
Control of pulsatile rotary pumps without pressure sensor
-
Trinkl J, Mesana T, Mitsui N, et al. Control of pulsatile rotary pumps without pressure sensor. ASAIO Trans 1991;37: M208-10.
-
(1991)
ASAIO Trans
, vol.37
-
-
Trinkl, J.1
Mesana, T.2
Mitsui, N.3
-
9
-
-
0342590072
-
An electrically-driven rotary blood pump based on the wankel engine
-
Akutsu T, Koyanagi H, eds. Tokyo: Springer-Verlag
-
Mitsui N, Havlik P, Mesana T, et al. An electrically-driven rotary blood pump based on the Wankel engine. In: Akutsu T, Koyanagi H, eds. Heart replacement: artificial heart 4. Tokyo: Springer-Verlag, 1993:281-6.
-
(1993)
Heart Replacement: Artificial Heart
, vol.4
, pp. 281-286
-
-
Mitsui, N.1
Havlik, P.2
Mesana, T.3
-
10
-
-
0028070136
-
Development of the Marseilles pulsatile rotary blood pump for permanent implantable left ventricular assistance
-
Monties JR, Havlik P, Mesana T, Trinkl J, Tourres JL, Demunck JL. Development of the Marseilles pulsatile rotary blood pump for permanent implantable left ventricular assistance. Artif Organs 1994;18:506-11.
-
(1994)
Artif Organs
, vol.18
, pp. 506-511
-
-
Monties, J.R.1
Havlik, P.2
Mesana, T.3
Trinkl, J.4
Tourres, J.L.5
Demunck, J.L.6
-
11
-
-
0020971069
-
Physiopathological studies of nonpulsatile blood flow in chronic models
-
Yada I, Golding LR, Harasaki H, et al. Physiopathological studies of nonpulsatile blood flow in chronic models. ASAIO Trans 1983;29:520-5.
-
(1983)
ASAIO Trans
, vol.29
, pp. 520-525
-
-
Yada, I.1
Golding, L.R.2
Harasaki, H.3
-
12
-
-
0023700189
-
Effects of nonpulsatile and pulsatile right ventricular bypass on pulmonary circulation
-
Taguchi S, Yozu R, Iseki H, Soma Y, Inoue T. Effects of nonpulsatile and pulsatile right ventricular bypass on pulmonary circulation. ASAIO Trans 1988;34:213-1.
-
(1988)
ASAIO Trans
, vol.34
, pp. 213-221
-
-
Taguchi, S.1
Yozu, R.2
Iseki, H.3
Soma, Y.4
Inoue, T.5
-
13
-
-
0025457114
-
Physiologic reactions of awake animals to an immediate switch from a pulsatile to nonpulsatile systemic circulation
-
Tenaka Y, Tatsumi E, Nakamura H, et al. Physiologic reactions of awake animals to an immediate switch from a pulsatile to nonpulsatile systemic circulation. ASAIO Trans 1990;36:M541-4.
-
(1990)
ASAIO Trans
, vol.36
-
-
Tenaka, Y.1
Tatsumi, E.2
Nakamura, H.3
-
14
-
-
0022751116
-
Idioperipheral pulsation during nonpulsatile biventricular bypass experiments
-
Tsutui T, Sutton C, Harasaki H, Jacob G, Golding L, Nosé Y. Idioperipheral pulsation during nonpulsatile biventricular bypass experiments. ASAIO Trans 1986;32:263-8.
-
(1986)
ASAIO Trans
, vol.32
, pp. 263-268
-
-
Tsutui, T.1
Sutton, C.2
Harasaki, H.3
Jacob, G.4
Golding, L.5
Nosé, Y.6
|