메뉴 건너뛰기




Volumn 177, Issue 1, 2005, Pages 60-66

Left ventricular functional parameters: Comparison of 16-slice spiral CT with MRI;Bestimmung linksventrikulärer funktionsparameter: Vergleich von 16-zeilen-mehrschicht-CT mit der MR-tomographie

Author keywords

Ejection fraction; Functional parameters; Magnetic resonance imaging (MRI); Multislice computed tomography (MSCT)

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY DISEASE; ELECTROCARDIOGRAM; FEMALE; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE FUNCTION; HEART STROKE VOLUME; HUMAN; IMAGE QUALITY; INTERMETHOD COMPARISON; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RETROSPECTIVE STUDY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 19944431052     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2004-813768     Document Type: Article
Times cited : (31)

References (36)
  • 1
    • 0033753104 scopus 로고    scopus 로고
    • Cardiac imaging by means of electrocardiographically gated multisection spiral CT: Initial experience
    • Ohnesorge B, Flohr T, Becker C et al. Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 2000; 217: 564-571
    • (2000) Radiology , vol.217 , pp. 564-571
    • Ohnesorge, B.1    Flohr, T.2    Becker, C.3
  • 2
    • 0035967495 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographyically-gated, multislice spiral computed tomography
    • Achenbach S, Giesler T, Ropers D et al. Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographyically-gated, multislice spiral computed tomography. Circulation 2001; 103: 2535-2538
    • (2001) Circulation , vol.103 , pp. 2535-2538
    • Achenbach, S.1    Giesler, T.2    Ropers, D.3
  • 3
    • 0035941737 scopus 로고    scopus 로고
    • Coronary angiography with multi-slice computed tomography
    • Nieman K, Oudkerk M, Rensing BJ et al. Coronary angiography with multi-slice computed tomography. Lancet 2001; 357: 599-603
    • (2001) Lancet , vol.357 , pp. 599-603
    • Nieman, K.1    Oudkerk, M.2    Rensing, B.J.3
  • 4
    • 0842280686 scopus 로고    scopus 로고
    • MDCT: Cardiology indications
    • Kopp AF, Kuttner A, Trabold T et al. MDCT: cardiology indications. Eur Radiol 2003; 13 (Suppl5): M102-115
    • (2003) Eur Radiol , vol.13 , Issue.SUPPL. 5
    • Kopp, A.F.1    Kuttner, A.2    Trabold, T.3
  • 5
    • 0021893531 scopus 로고
    • Prognostic significance of progression of coronary artery disease
    • Moise A, Bourassa MG, Theroux P et al. Prognostic significance of progression of coronary artery disease. Am J Cardiol 1985; 55: 941-946
    • (1985) Am J Cardiol , vol.55 , pp. 941-946
    • Moise, A.1    Bourassa, M.G.2    Theroux, P.3
  • 6
    • 0027991120 scopus 로고
    • Evaluation of cardiac function with magnetic resonance imaging
    • Pattynama PM, De Roos A, Van der Wall EE et al. Evaluation of cardiac function with magnetic resonance imaging. Am Heart J 1994; 128: 595-607
    • (1994) Am Heart J , vol.128 , pp. 595-607
    • Pattynama, P.M.1    De Roos, A.2    Van Der Wall, E.E.3
  • 7
    • 1842750672 scopus 로고    scopus 로고
    • Imaging of ventricular function by cardiovascular magnetic resonance
    • Rathi VK, Biedermann RW. Imaging of ventricular function by cardiovascular magnetic resonance. Curr Cardiol Rep 2004; 6: 55-61
    • (2004) Curr Cardiol Rep , vol.6 , pp. 55-61
    • Rathi, V.K.1    Biedermann, R.W.2
  • 8
    • 0012796666 scopus 로고    scopus 로고
    • Evaluation of left ventricular function by retrospectively ECG-gated multislice spiral CT in comparison to CINE magnetic resonance imaging
    • Juergens KU, Fischbach R, Grude M et al. Evaluation of left ventricular function by retrospectively ECG-gated multislice spiral CT in comparison to CINE magnetic resonance imaging. Eur Radiol 2002; 12 (Suppl): S191
    • (2002) Eur Radiol , vol.12 , Issue.SUPPL.
    • Juergens, K.U.1    Fischbach, R.2    Grude, M.3
  • 9
    • 0037250086 scopus 로고    scopus 로고
    • Quantifizierung der herzfunktion in der mehrschicht spiral CT mit retrospektivem EKG-gating: Vergleich zur kernspintomographie
    • Mahnken AH, Süntrup E, Wildberger JE et al. Quantifizierung der Herzfunktion in der Mehrschicht Spiral CT mit retrospektivem EKG-Gating: Vergleich zur Kernspintomographie. Fortschr Röntgenstr 2003; 175: 83-88
    • (2003) Fortschr Röntgenstr , vol.175 , pp. 83-88
    • Mahnken, A.H.1    Süntrup, E.2    Wildberger, J.E.3
  • 10
    • 0001237180 scopus 로고    scopus 로고
    • Beurteilung der linksventrikulären pumpfunktion mit EKG-gesteuerter Mehrschicht CT: Vergleich mit der invasiven ventrikulographie
    • Wintersperger B, Hundt W, Knez A et al. Beurteilung der linksventrikulären Pumpfunktion mit EKG-gesteuerter Mehrschicht CT: Vergleich mit der invasiven Ventrikulographie. Fortschr Röntgenstr 2002; 174: S137
    • (2002) Fortschr Röntgenstr , vol.174
    • Wintersperger, B.1    Hundt, W.2    Knez, A.3
  • 11
    • 0012352395 scopus 로고    scopus 로고
    • Bestimmung der linksventrikulären pumpfunktion in der kardialen mehrzeilen spiral-CT
    • Herzog C, Bitten M, Ay N et al. Bestimmung der linksventrikulären Pumpfunktion in der kardialen Mehrzeilen Spiral-CT. Fortschr Röntgenstr 2002; 174: S136-S137
    • (2002) Fortschr Röntgenstr , vol.174
    • Herzog, C.1    Bitten, M.2    Ay, N.3
  • 12
    • 0242268620 scopus 로고    scopus 로고
    • Bestimmung linksventrikulärer funktionsparameter mittels EKG-gesteuerter mehrschicht-computertomographie im vergleich mit der invasiven ventrikulographie
    • Heuschmid M, Küttner A, Schröder S et al. Bestimmung linksventrikulärer Funktionsparameter mittels EKG-gesteuerter Mehrschicht-Computertomographie im Vergleich mit der invasiven Ventrikulographie. Fortschr Röntgenstr 2003; 175: 1349-1354
    • (2003) Fortschr Röntgenstr , vol.175 , pp. 1349-1354
    • Heuschmid, M.1    Küttner, A.2    Schröder, S.3
  • 13
    • 0036373605 scopus 로고    scopus 로고
    • New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging
    • Flohr T, Bruder H, Stierstorfer K et al. New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Fortschr Röntgenstr 2002; 174: 1022-1027
    • (2002) Fortschr Röntgenstr , vol.174 , pp. 1022-1027
    • Flohr, T.1    Bruder, H.2    Stierstorfer, K.3
  • 14
    • 0035178084 scopus 로고    scopus 로고
    • Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography
    • Schalla S, Nagel E, Lehmkuhl H et al. Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography. Am J Cardiol 2001; 87: 95-99
    • (2001) Am J Cardiol , vol.87 , pp. 95-99
    • Schalla, S.1    Nagel, E.2    Lehmkuhl, H.3
  • 15
    • 0024268651 scopus 로고
    • Mode of death in ideopathic dilated cardiomyopathy: A multivariate analysis of prognostic determinants
    • Hofmann T, Meinertz T, Kasper W et al. Mode of death in ideopathic dilated cardiomyopathy: a multivariate analysis of prognostic determinants. Am Heart J 1988; 116: 1455-1463
    • (1988) Am Heart J , vol.116 , pp. 1455-1463
    • Hofmann, T.1    Meinertz, T.2    Kasper, W.3
  • 16
    • 0036818493 scopus 로고    scopus 로고
    • Quantitaion of left ventricular mass and function: Balancing evidence with dreams
    • de Simone G, Galderisi M. Quantitaion of left ventricular mass and function: balancing evidence with dreams. Ital Heart J 2002; 3: 562-570
    • (2002) Ital Heart J , vol.3 , pp. 562-570
    • De Simone, G.1    Galderisi, M.2
  • 17
    • 0033018548 scopus 로고    scopus 로고
    • Global left ventricular cardiac function: Comparison between magnetic resonance imaging, radionuclide angiography, and contrast angiography
    • Lethimonnier F, Furber A, Balzer P et al. Global left ventricular cardiac function: comparison between magnetic resonance imaging, radionuclide angiography, and contrast angiography. Invest Radiol 1999; 34: 199-203
    • (1999) Invest Radiol , vol.34 , pp. 199-203
    • Lethimonnier, F.1    Furber, A.2    Balzer, P.3
  • 18
    • 0031802403 scopus 로고    scopus 로고
    • Nuclear cardiology: Scintigraphic evaluation of cardiac function
    • Hambye AS, Everaert H, Maes M et al. Nuclear cardiology: Scintigraphic evaluation of cardiac function. J Nucl Med Technol 1998; 26: 72-79
    • (1998) J Nucl Med Technol , vol.26 , pp. 72-79
    • Hambye, A.S.1    Everaert, H.2    Maes, M.3
  • 22
    • 0033845492 scopus 로고    scopus 로고
    • Quantification of left ventricular function with magnetic resonance images acquired in real time
    • Setser RM, Fischer SE, Lorenz CH. Quantification of left ventricular function with magnetic resonance images acquired in real time. J Magn Reson Imaging 2000; 12: 430-438
    • (2000) J Magn Reson Imaging , vol.12 , pp. 430-438
    • Setser, R.M.1    Fischer, S.E.2    Lorenz, C.H.3
  • 23
    • 0036206953 scopus 로고    scopus 로고
    • MR Imaging of the heart with cine true fast imaging with steady-state precession: Influence of spatial and temporal resolution on left ventricular functional parameters
    • Miller S, Simonetti OP, Carr J et al. MR Imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolution on left ventricular functional parameters. Radiology 2002; 223: 263-269
    • (2002) Radiology , vol.223 , pp. 263-269
    • Miller, S.1    Simonetti, O.P.2    Carr, J.3
  • 24
    • 6044274208 scopus 로고    scopus 로고
    • Leitlinien für den einsatz der computertomographie in der diagnostik des herzens und der großen thorakalen gefäße
    • Arbeitsgemeinschaft Herzdiagnostik. Leitlinien für den Einsatz der Computertomographie in der Diagnostik des Herzens und der großen thorakalen Gefäße. Fortschr Röntgenstr 2004; 176: 632-637
    • (2004) Fortschr Röntgenstr , vol.176 , pp. 632-637
  • 25
    • 0037432175 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    • Ropers D, Baum U, Pohle K et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 2003; 107: 664-666
    • (2003) Circulation , vol.107 , pp. 664-666
    • Ropers, D.1    Baum, U.2    Pohle, K.3
  • 26
    • 0034867726 scopus 로고    scopus 로고
    • ECG-gated reconstructed multi-detector row CT coronary angiography: Effect of varying trigger delay on image quality
    • Hong C, Becker CR, Huber A et al. ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 2001; 200: 712-717
    • (2001) Radiology , vol.200 , pp. 712-717
    • Hong, C.1    Becker, C.R.2    Huber, A.3
  • 27
    • 2442654188 scopus 로고    scopus 로고
    • Time effectiveness, oberserver-depencence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT
    • Boehm T, Alkadhi H, Roffi M et al. Time effectiveness, oberserver-depencence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT. Fortschr Röntgenstr 2004; 176: 529-537
    • (2004) Fortschr Röntgenstr , vol.176 , pp. 529-537
    • Boehm, T.1    Alkadhi, H.2    Roffi, M.3
  • 28
    • 0036178927 scopus 로고    scopus 로고
    • Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: Experience in 94 patients
    • Schroeder S, Kopp AF, Kuettner A et al. Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clin Imaging 2002; 26: 106-111
    • (2002) Clin Imaging , vol.26 , pp. 106-111
    • Schroeder, S.1    Kopp, A.F.2    Kuettner, A.3
  • 29
    • 0036783789 scopus 로고    scopus 로고
    • Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection
    • Giesler T, Baum U, Ropers D et al. Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection. AJR Am J Roentgenol 2002; 179: 911-916
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 911-916
    • Giesler, T.1    Baum, U.2    Ropers, D.3
  • 30
    • 0345689655 scopus 로고    scopus 로고
    • Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: Value of different image reconstruction algorithms in comparison to MRI
    • Mahnken AH, Suentrup E, Niethammer M et al. Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI. Acta Radiologica 2003; 44: 604-611
    • (2003) Acta Radiologica , vol.44 , pp. 604-611
    • Mahnken, A.H.1    Suentrup, E.2    Niethammer, M.3
  • 31
    • 0036924043 scopus 로고    scopus 로고
    • Mehrschicht-CT des herzens: Schwellenwertgestützte 3D-volumetrie zur bestimmung der linksventrikulären pumpfunktion im vergleich zur magnetresonanztomographie
    • Ehrhard K, Oberholzer K, Gast K et al. Mehrschicht-CT des Herzens: Schwellenwertgestützte 3D-Volumetrie zur Bestimmung der linksventrikulären Pumpfunktion im Vergleich zur Magnetresonanztomographie. Fortschr Röntgenstr 2002; 174: 1566-1569
    • (2002) Fortschr Röntgenstr , vol.174 , pp. 1566-1569
    • Ehrhard, K.1    Oberholzer, K.2    Gast, K.3
  • 32
    • 0035088021 scopus 로고    scopus 로고
    • MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
    • Barkhausen J, Ruehm SG, Goyen M et al. MR Evaluation of Ventricular Function: True Fast Imaging with Steady-State Precession versus Fast Low-Angle Shot Cine MR Imaging: Feasibility Study. Radiology 2001; 219: 264-269
    • (2001) Radiology , vol.219 , pp. 264-269
    • Barkhausen, J.1    Ruehm, S.G.2    Goyen, M.3
  • 33
    • 84866223400 scopus 로고    scopus 로고
    • Abschätzung der effektiven dosis für routineprotokolle beim konventionellen CT, elektronenstrahl-CT und bei der koronarangiographie
    • Becker C, Schätzl M, Feist H et al. Abschätzung der effektiven Dosis für Routineprotokolle beim konventionellen CT, Elektronenstrahl-CT und bei der Koronarangiographie. Fortsch Röntgenstr 1999; 170: 99-104
    • (1999) Fortsch Röntgenstr , vol.170 , pp. 99-104
    • Becker, C.1    Schätzl, M.2    Feist, H.3
  • 34
    • 0037254248 scopus 로고    scopus 로고
    • Radiation exposure during cardiac CT
    • Hunold P, Vogt FM, Schmermund A et al. Radiation exposure during cardiac CT. Radiology 2003; 226: 145-152
    • (2003) Radiology , vol.226 , pp. 145-152
    • Hunold, P.1    Vogt, F.M.2    Schmermund, A.3
  • 35
    • 0035055659 scopus 로고    scopus 로고
    • Radiation exposure in multi-slice CT of the heart
    • Cohnen M, Poll L, Puttmann C et al. Radiation exposure in multi-slice CT of the heart. Fortschr Röntgenstr 2001; 173: 295-299
    • (2001) Fortschr Röntgenstr , vol.173 , pp. 295-299
    • Cohnen, M.1    Poll, L.2    Puttmann, C.3
  • 36
    • 0041322599 scopus 로고    scopus 로고
    • Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating
    • Trabold T, Buchgeister M, Küttner A et al. Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Fortschr Röntgenstr 2003; 175: 1051-55
    • (2003) Fortschr Röntgenstr , vol.175 , pp. 1051-1055
    • Trabold, T.1    Buchgeister, M.2    Küttner, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.