메뉴 건너뛰기




Volumn 95, Issue 1, 2005, Pages 107-109

Intravascular ultrasound assessment of neointima distribution and the length of stent that was free of intravascular ultrasound-detectable intimal hyperplasia in paclitaxel-eluting stents

Author keywords

[No Author keywords available]

Indexed keywords

PACLITAXEL;

EID: 19944408197     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjcard.2004.08.072     Document Type: Article
Times cited : (17)

References (11)
  • 4
    • 0042388295 scopus 로고    scopus 로고
    • Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions
    • TAXUS II Study Group M.E.
    • A. Colombo, J. Drzewiecki, A. Banning, E. Grube, K. Hauptmann, S. Silber, D. Dudek, S. Fort, F. Schiele, K. Zmudka, G. Guagliumi, M.E. Russell TAXUS II Study Group Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions Circulation 108 2003 788 794
    • (2003) Circulation , vol.108 , pp. 788-794
    • Colombo, A.1    Drzewiecki, J.2    Banning, A.3    Grube, E.4    Hauptmann, K.5    Silber, S.6    Dudek, D.7    Fort, S.8    Schiele, F.9    Zmudka, K.10    Guagliumi, G.11    Russell12
  • 5
    • 0037072467 scopus 로고    scopus 로고
    • Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial
    • RAVEL Study Group M.C.
    • P.W. Serruys, M. Degertekin, K. Tanabe, A. Abizaid, J.E. Sousa, A. Colombo, G. Guagliumi, W. Wijns, W.K. Lindeboom, J. Ligthart, P.J. de Feyter, M.C. Morice RAVEL Study Group Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial Circulation 106 2002 798 803
    • (2002) Circulation , vol.106 , pp. 798-803
    • Serruys, P.W.1    Degertekin, M.2    Tanabe, K.3    Abizaid, A.4    Sousa, J.E.5    Colombo, A.6    Guagliumi, G.7    Wijns, W.8    Lindeboom, W.K.9    Ligthart, J.10    De Feyter, P.J.11    Morice12
  • 6
    • 0345526804 scopus 로고    scopus 로고
    • Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: An intravascular ultrasound analysis
    • M. Degertekin, P.W. Serruys, K. Tanabe, C.H. Lee, J.E. Sousa, A. Colombo, M.C. Morice, J.M. Ligthart, P.J. de Feyter Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: an intravascular ultrasound analysis Circulation 108 2003 2747 2750
    • (2003) Circulation , vol.108 , pp. 2747-2750
    • Degertekin, M.1    Serruys, P.W.2    Tanabe, K.3    Lee, C.H.4    Sousa, J.E.5    Colombo, A.6    Morice, M.C.7    Ligthart, J.M.8    De Feyter, P.J.9
  • 7
    • 9144238090 scopus 로고    scopus 로고
    • Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: Comparison with bare metal stents by serial intravascular ultrasound analyses: Data from the randomized TAXUS-II trial
    • TAXUS II Study Group L.
    • K. Tanabe, P.W. Serruys, M. Degertekin, G. Guagliumi, E. Grube, C. Chan, T. Munzel, J. Belardi, W. Ruzyllo, L. Bilodeau TAXUS II Study Group Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-II trial Circulation 109 2004 196 200
    • (2004) Circulation , vol.109 , pp. 196-200
    • Tanabe, K.1    Serruys, P.W.2    Degertekin, M.3    Guagliumi, G.4    Grube, E.5    Chan, C.6    Munzel, T.7    Belardi, J.8    Ruzyllo, W.9    Bilodeau10
  • 8
    • 10744233974 scopus 로고    scopus 로고
    • Vascular responses at proximal and distal edges of paclitaxel-eluting stents: Serial intravascular ultrasound analysis from the TAXUS II trial
    • TAXUS II Study Group R.
    • P.W. Serruys, M. Degertekin, K. Tanabe, M.E. Russell, G. Guagliumi, J. Webb, J. Hamburger, W. Rutsch, C. Kaiser, R. Whitbourn TAXUS II Study Group Vascular responses at proximal and distal edges of paclitaxel-eluting stents: serial intravascular ultrasound analysis from the TAXUS II trial Circulation 109 2004 627 633
    • (2004) Circulation , vol.109 , pp. 627-633
    • Serruys, P.W.1    Degertekin, M.2    Tanabe, K.3    Russell, M.E.4    Guagliumi, G.5    Webb, J.6    Hamburger, J.7    Rutsch, W.8    Kaiser, C.9    Whitbourn10
  • 11
    • 0035312809 scopus 로고    scopus 로고
    • Standards for the acquisition, measurement, and reporting of intravascular ultrasound studies: A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    • G.S. Mintz, S.E. Nissen, W.D. Anderson, S.R. Bailey, R. Erbel, P.J. Fitzgerald, F.J. Pinto, K. Rosenfield, R.J. Siegel, E.M. Tuzcu, P.G. Yock Standards for the acquisition, measurement, and reporting of intravascular ultrasound studies: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents J Am Coll Cardiol 37 2001 1478 1492
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1478-1492
    • Mintz, G.S.1    Nissen, S.E.2    Anderson, W.D.3    Bailey, S.R.4    Erbel, R.5    Fitzgerald, P.J.6    Pinto, F.J.7    Rosenfield, K.8    Siegel, R.J.9    Tuzcu, E.M.10    Yock, P.G.11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.