메뉴 건너뛰기




Volumn 5501, Issue , 2004, Pages 66-77

CCD detector development for the DUO and the ROSITA mission

Author keywords

DUO; Frame store; Fully depleted CCD; PN CCD; ROSITA; X ray detector

Indexed keywords

CHARGE COUPLED DEVICES; CHARGE TRANSFER; OPTICAL FILTERS; SIGNAL PROCESSING; TELESCOPES; X RAYS;

EID: 19944394523     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.551505     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 1
    • 10044297411 scopus 로고    scopus 로고
    • DUO - The dark universe observatory
    • UV-Gamma Ray Space Telescope Systems, G. Hasinger and M. J. L. Turner, eds
    • R. E. Griffiths, R. Petre , G. Hasinger, et al., "DUO - the Dark Universe Observatory", in UV-Gamma Ray Space Telescope Systems, G. Hasinger and M. J. L. Turner, eds., Proc. SPIE 5488, 2004.
    • (2004) Proc. SPIE , vol.5488
    • Griffiths, R.E.1    Petre, R.2    Hasinger, G.3
  • 2
    • 10044281835 scopus 로고    scopus 로고
    • The x-ray telescope ROSITA on its way to orbit
    • UV-Gamma Ray Space Telescope Systems, G. Hasinger and M. J. L. Turner, eds
    • T. Stuffier, S. Hofer, P. Predehl, and G. Hasinger, "The X-ray telescope ROSITA on its way to orbit", in UV-Gamma Ray Space Telescope Systems, G. Hasinger and M. J. L. Turner, eds., Proc. SPIE 5488, 2004.
    • (2004) Proc. SPIE , vol.5488
    • Stuffier, T.1    Hofer, S.2    Predehl, P.3    Hasinger, G.4
  • 3
    • 10044225891 scopus 로고    scopus 로고
    • The dark universe observatory (DUO) - Telescope concept
    • UV-Gamma Ray Space Telescope Systems, G. Hasinger and M. J. L. Turner, eds
    • P. Friedrich, P. Predehl, H. Böhringer, et al., "The Dark Universe Observatory (DUO) - Telescope Concept", in UV-Gamma Ray Space Telescope Systems, G. Hasinger and M. J. L. Turner, eds., Proc. SPIE 5488, 2004.
    • (2004) Proc. SPIE , vol.5488
    • Friedrich, P.1    Predehl, P.2    Böhringer, H.3
  • 4
    • 2942588079 scopus 로고    scopus 로고
    • The ROSAT all-sky survey bright source catalogue
    • W. Voges, B. Aschenbach, Th. Boller, "The ROSAT All-Sky Survey Bright Source Catalogue", Astronomy & Astrophysics, Vol.349, pp.389-405, 1999.
    • (1999) Astronomy & Astrophysics , vol.349 , pp. 389-405
    • Voges, W.1    Aschenbach, B.2    Boller, Th.3
  • 5
    • 10844238895 scopus 로고    scopus 로고
    • Shielding of cosmic ray induced background in CCD detectors for x-ray astronomy
    • High-Energy Detectors in Astronomy, A. D. Holland and L. Strüder, eds., this volume
    • E. Pfeffermann, P. Friedrich, M. Freyberg, G. Kettenring, L. Krämer, N. Meidinger, P. Predehl, and L. Strüder, "Shielding of cosmic ray induced background in CCD detectors for X-ray astronomy", in High-Energy Detectors in Astronomy, A. D. Holland and L. Strüder, eds., Proc. SPIE 5501, this volume, 2004.
    • (2004) Proc. SPIE , vol.5501
    • Pfeffermann, E.1    Friedrich, P.2    Freyberg, M.3    Kettenring, G.4    Krämer, L.5    Meidinger, N.6    Predehl, P.7    Strüder, L.8
  • 6
    • 0242538711 scopus 로고    scopus 로고
    • The European photon imaging camera on XMM-Newton: The pn-CCD camera
    • L. Strüder, U. Briel, K. Dennerl, et al., "The European Photon Imaging Camera on XMM-Newton: The pn-CCD camera", Astronomy & Astrophysics, vol. 365, 1, pp. L18-L26, 2001.
    • (2001) Astronomy & Astrophysics , vol.365 , Issue.1
    • Strüder, L.1    Briel, U.2    Dennerl, K.3
  • 7
    • 19244367027 scopus 로고    scopus 로고
    • First measurements with a frame store pn-CCD x-ray detector
    • N. Meidinger, S. Bonerz, R. Eckhardt, et al., "First measurements with a frame store pn-CCD X-ray detector", Nucl. Instr. & Meth., A 512, pp.341-349, 2003.
    • (2003) Nucl. Instr. & Meth., A , vol.512 , pp. 341-349
    • Meidinger, N.1    Bonerz, S.2    Eckhardt, R.3
  • 8
    • 11144358329 scopus 로고    scopus 로고
    • Frame store PN-CCD detector for space applications
    • N. Meidinger, S. Bonerz, H. Bräuninger, et al., "Frame Store PN-CCD Detector for Space Applications", Proc. SPIE 5165, pp.26-36, 2003.
    • (2003) Proc. SPIE , vol.5165 , pp. 26-36
    • Meidinger, N.1    Bonerz, S.2    Bräuninger, H.3
  • 9
    • 0038633505 scopus 로고    scopus 로고
    • Frame store PN-CCD detector for the ROSITA mission
    • N. Meidinger, S. Bonerz, H. Bräuninger, et al., "Frame Store PN-CCD Detector for the ROSITA Mission", Proc. SPIE 4851, pp. 1040-1047, 2002.
    • (2002) Proc. SPIE , vol.4851 , pp. 1040-1047
    • Meidinger, N.1    Bonerz, S.2    Bräuninger, H.3
  • 10
    • 0031145561 scopus 로고    scopus 로고
    • New technique of the x-ray efficiency measurement of a charge coupled device with a subpixel resolution
    • H. Tsunemi, K. Yoshita, and S. Kitamoto, "New Technique of the X-Ray Efficiency Measurement of a Charge Coupled Device with a Subpixel Resolution", Jpn. J. Appl. Phys., 36, pp.2906-2911, 1997.
    • (1997) Jpn. J. Appl. Phys. , vol.36 , pp. 2906-2911
    • Tsunemi, H.1    Yoshita, K.2    Kitamoto, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.