메뉴 건너뛰기




Volumn 5, Issue 3, 2005, Pages 340-344

Si-based sensor for virus detection

Author keywords

Analog integrated circuits; Biomedical tranducers; Capacitance measurement; Dielectric material; Differential amplifiers

Indexed keywords

CAPACITANCE; DIFFERENTIAL AMPLIFIERS; INTEGRATED CIRCUITS; PROBLEM SOLVING; SENSORS; SILICON; TRANSDUCERS;

EID: 19944380457     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2005.844543     Document Type: Article
Times cited : (44)

References (28)
  • 3
    • 19944398212 scopus 로고    scopus 로고
    • A biosensor system to monitor water-borne pathogens; coupling immunomagnetic capture and magnetically stabilized fluid bed technologies to detect Giardia cysts
    • D. F. Koufas and R. J. Fisher, "A biosensor system to monitor water-borne pathogens; coupling immunomagnetic capture and magnetically stabilized fluid bed technologies to detect Giardia cysts," presented at the IEEE 24th Annu. Northeast Bioengineering Conf., 1998.
    • (1998) IEEE 24th Annu. Northeast Bioengineering Conf.
    • Koufas, D.F.1    Fisher, R.J.2
  • 6
    • 0035510213 scopus 로고    scopus 로고
    • Dielectrophoretic detection of molecular bindings
    • Nov./Dec.
    • T. W. Kawabata and M. Washizu, "Dielectrophoretic detection of molecular bindings," IEEE Trans. Ind. Appl., vol. 37, no. 6, pp. 1625-1633, Nov./Dec. 2001.
    • (2001) IEEE Trans. Ind. Appl. , vol.37 , Issue.6 , pp. 1625-1633
    • Kawabata, T.W.1    Washizu, M.2
  • 7
    • 0035151795 scopus 로고    scopus 로고
    • Selective detection of bacteria using dielectrophoretic impedance measurement method combined with antigen-antibody reaction
    • J. N. Suehiro, D. Noutomi, R. Hamada, and M. Hara, "Selective detection of bacteria using dielectrophoretic impedance measurement method combined with antigen-antibody reaction," presented at the IEEE 36th IAS Annu. Meeting Industry Applications Conf., 2001.
    • (2001) IEEE 36th IAS Annu. Meeting Industry Applications Conf.
    • Suehiro, J.N.1    Noutomi, D.2    Hamada, R.3    Hara, M.4
  • 9
    • 0035385951 scopus 로고    scopus 로고
    • The use of derivatized magnetoliposomes for extraction of antibodies from aqueous solutions
    • Jul.
    • G. K. Dumitrascu, A. Kumbhar, W. Zhou, and Z. Rosenzweig, "The use of derivatized magnetoliposomes for extraction of antibodies from aqueous solutions," IEEE Trans. Magn., vol. 37, no. 4, pp. 2932-2934, Jul. 2001.
    • (2001) IEEE Trans. Magn. , vol.37 , Issue.4 , pp. 2932-2934
    • Dumitrascu, G.K.1    Kumbhar, A.2    Zhou, W.3    Rosenzweig, Z.4
  • 11
    • 0030688645 scopus 로고    scopus 로고
    • Highly sensitive detection of morphine by using immunosensor based on surface-plasmonresonance
    • G. O. Sakai, I., T. Uda, N. Miura, and N. Yamazoe, "Highly sensitive detection of morphine by using immunosensor based on surface-plasmonresonance, " presented at the Int. Conf. Solid State Sensors and Actuators, 1997.
    • (1997) Int. Conf. Solid State Sensors and Actuators
    • Sakai, G.O.1    Uda, T.2    Miura, N.3    Yamazoe, N.4
  • 16
    • 0035296987 scopus 로고    scopus 로고
    • Making chips to probe genes
    • Jan.
    • S. K. Moore, "Making chips to probe genes," IEEE Spectrum, vol. 38, no. 1, pp. 54-60, Jan. 2001.
    • (2001) IEEE Spectrum , vol.38 , Issue.1 , pp. 54-60
    • Moore, S.K.1
  • 17
    • 0032213037 scopus 로고    scopus 로고
    • An immunological interleukin-6 capacitive biosensor using perturbation with a potentiostatic step
    • C. Berggren, B. Bjarnason, and G. Johansson, "An immunological interleukin-6 capacitive biosensor using perturbation with a potentiostatic step," Biosens. Bioelectron., vol. 13, pp. 1061-1068, 1998.
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 1061-1068
    • Berggren, C.1    Bjarnason, B.2    Johansson, G.3
  • 18
    • 19944369495 scopus 로고
    • "Optimized capacitive sensor for chemical analysis and measurement," U.S. Patent 4,822,566, Apr.
    • A. L. Newman, "Optimized capacitive sensor for chemical analysis and measurement," U.S. Patent 4,822,566, Apr. 1989.
    • (1989)
    • Newman, A.L.1
  • 19
    • 19944369838 scopus 로고
    • "Molecular biological diagnostic systems including electrodes," U.S. Patent 5,632,957, May
    • M. J. Heller, E. Tu, and W. F. Butler, "Molecular biological diagnostic systems including electrodes," U.S. Patent 5,632,957, May 1994.
    • (1994)
    • Heller, M.J.1    Tu, E.2    Butler, W.F.3
  • 20
    • 19944377258 scopus 로고
    • "Silicon Semiconductor wafer for analyzing micronic biological samples," U.S. Patent 4,908,112, Mar.
    • E. R. Martin, "Silicon Semiconductor wafer for analyzing micronic biological samples," U.S. Patent 4,908,112, Mar. 1990.
    • (1990)
    • Martin, E.R.1
  • 21
    • 19944362577 scopus 로고
    • "Multiple chemically modulated capacitance determination," U.S. Patent 5,164,319, Nov.
    • D. G. Hafeman and H. M. McConnell, "Multiple chemically modulated capacitance determination," U.S. Patent 5,164,319, Nov. 1992.
    • (1992)
    • Hafeman, D.G.1    McConnell, H.M.2
  • 23
    • 0027497767 scopus 로고
    • Influence of defects on the electrophoretic, thermodynamic and dielectric-properties of a 21 base pair DNA in solution
    • A. Bonincontro, M. Matzeu, F. Mazzei, A. Minoprio, and F. Pedone, "Influence of defects on the electrophoretic, thermodynamic and dielectric-properties of a 21 base pair DNA in solution," Biochim. Biophys. Acta, vol. 1171, pp. 288-294, 1993.
    • (1993) Biochim. Biophys. Acta , vol.1171 , pp. 288-294
    • Bonincontro, A.1    Matzeu, M.2    Mazzei, F.3    Minoprio, A.4    Pedone, F.5
  • 24
    • 0028891214 scopus 로고
    • Dielectric studies of ion fluctuation and chain bending in native DNA
    • S. Bone and C. A. Small, "Dielectric studies of ion fluctuation and chain bending in native DNA," Biochim. Biophys. Acta, vol. 1260, pp. 85-93, 1995.
    • (1995) Biochim. Biophys. Acta , vol.1260 , pp. 85-93
    • Bone, S.1    Small, C.A.2
  • 26
    • 0036505228 scopus 로고    scopus 로고
    • Sense amplifier signal margins and process sensitivities [DRAM]
    • Jun./Jul.
    • D. G. Laurent, "Sense amplifier signal margins and process sensitivities [DRAM]," IEEE Trans. Circuits and Systems I: Fundam. Theory Appl., vol. 49, no. 2, pp. 269-275, Jun./Jul. 2002.
    • (2002) IEEE Trans. Circuits and Systems I: Fundam. Theory Appl. , vol.49 , Issue.2 , pp. 269-275
    • Laurent, D.G.1
  • 27
    • 0026896296 scopus 로고
    • Experimental investigation of the minimum signal for reliable operation of DRAM sense amplifiers
    • Jul.
    • H. W. Geib, W. Weber, E. Wohlrab, and L. Risch, "Experimental investigation of the minimum signal for reliable operation of DRAM sense amplifiers," IEEE J. Solid-State Circuits, vol. 27, no. 7, pp. 1028-1035, Jul. 1992.
    • (1992) IEEE J. Solid-state Circuits , vol.27 , Issue.7 , pp. 1028-1035
    • Geib, H.W.1    Weber, W.2    Wohlrab, E.3    Risch, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.