메뉴 건너뛰기




Volumn 19, Issue 5, 2005, Pages 309-325

Management of diabetes using adaptive control

Author keywords

Diabetes management; Insulin treatment; Off line adaptation; On line adaptation

Indexed keywords

ADAPTIVE CONTROL SYSTEMS; BIOSENSORS; GLUCOSE; INSULIN; METABOLITES; ONLINE SYSTEMS; PATIENT TREATMENT;

EID: 19944370823     PISSN: 08906327     EISSN: None     Source Type: Journal    
DOI: 10.1002/acs.851     Document Type: Review
Times cited : (51)

References (105)
  • 1
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long term complications in insulin-dependent diabetes mellitus
    • Diabetic Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long term complications in insulin-dependent diabetes mellitus. The New England Journal of Medicine 1993; 329:977-986.
    • (1993) The New England Journal of Medicine , vol.329 , pp. 977-986
  • 4
    • 84907107765 scopus 로고
    • Application of computers in diabetes care - A review. II. Computers for decision support and education
    • Lehmann ED, Deutsch T. Application of computers in diabetes care - a review. II. Computers for decision support and education. Medical Informatics (London) 1995; 20:303-329.
    • (1995) Medical Informatics (London) , vol.20 , pp. 303-329
    • Lehmann, E.D.1    Deutsch, T.2
  • 7
    • 0037289237 scopus 로고    scopus 로고
    • Electronic management systems in diabetes mellitus - Impact on patient outcomes
    • Bellazzi R. Electronic management systems in diabetes mellitus - impact on patient outcomes. Disease Management & Health Outcomes 2003; 11:159-171.
    • (2003) Disease Management & Health Outcomes , vol.11 , pp. 159-171
    • Bellazzi, R.1
  • 8
    • 0022449849 scopus 로고
    • Diabetes in pregnancy: Evaluating self-monitoring performance and glycaemic control with memory-based reflectance meters
    • Langer O, Mazze RS. Diabetes in pregnancy: evaluating self-monitoring performance and glycaemic control with memory-based reflectance meters. American Journal of Obstetrics and Gynecology 1986; 155:635-637.
    • (1986) American Journal of Obstetrics and Gynecology , vol.155 , pp. 635-637
    • Langer, O.1    Mazze, R.S.2
  • 12
    • 0024443126 scopus 로고
    • Computer simulation of plasma insulin and glucose dynamics after subcutaneous insulin injection
    • Berger MP, Rodbard D. Computer simulation of plasma insulin and glucose dynamics after subcutaneous insulin injection. Diabetes Care 1989; 12:725-736.
    • (1989) Diabetes Care , vol.12 , pp. 725-736
    • Berger, M.P.1    Rodbard, D.2
  • 13
    • 1542439960 scopus 로고    scopus 로고
    • Performance assessment of the Medtronic-MiniMed continuous glucose monitoring system and its use for measurement of glycaemic control in Type 1 diabetic subjects
    • Sachedina N, Pickup JC. Performance assessment of the Medtronic-MiniMed continuous glucose monitoring system and its use for measurement of glycaemic control in Type 1 diabetic subjects. Diabetic Medicine 2003; 20:1012-1015.
    • (2003) Diabetic Medicine , vol.20 , pp. 1012-1015
    • Sachedina, N.1    Pickup, J.C.2
  • 18
    • 0032078667 scopus 로고    scopus 로고
    • Mixed graphical models for simultaneous model identification and control applied to the glucose-insulin metabolism
    • Bleckert G, Oppel UG, Salzsieder E. Mixed graphical models for simultaneous model identification and control applied to the glucose-insulin metabolism. Computer Methods and Programs in Biomedicine 1998; 56: 141-155.
    • (1998) Computer Methods and Programs in Biomedicine , vol.56 , pp. 141-155
    • Bleckert, G.1    Oppel, U.G.2    Salzsieder, E.3
  • 19
    • 0000445747 scopus 로고
    • Causal probabilistic network modelling - An illustration of its role in the management of chronic diseases
    • Hovorka R, Andreassen S, Benn JJ, Olessen KG, Carson ER. Causal probabilistic network modelling - an illustration of its role in the management of chronic diseases. IBM Systems Journal 1992; 31:635-648.
    • (1992) IBM Systems Journal , vol.31 , pp. 635-648
    • Hovorka, R.1    Andreassen, S.2    Benn, J.J.3    Olessen, K.G.4    Carson, E.R.5
  • 25
  • 28
    • 0024205566 scopus 로고
    • Computer-based patient monitoring systems. Use in research and clinical practice
    • Zimmet P, Lang A, Mazze RS, Endersbee R. Computer-based patient monitoring systems. Use in research and clinical practice. Diabetes Care 1988; 11(Suppl.):62-66.
    • (1988) Diabetes Care , vol.11 , Issue.SUPPL. , pp. 62-66
    • Zimmet, P.1    Lang, A.2    Mazze, R.S.3    Endersbee, R.4
  • 30
    • 0041667823 scopus 로고    scopus 로고
    • Diabetes and telemedicine: Is the technology sound, effective, cost-effective, and practical?
    • Klonoff DC. Diabetes and telemedicine: is the technology sound, effective, cost-effective, and practical? Diabetes Care 2003; 26:1626-1628.
    • (2003) Diabetes Care , vol.26 , pp. 1626-1628
    • Klonoff, D.C.1
  • 31
    • 0036291924 scopus 로고    scopus 로고
    • Are there time and cost savings by using telemanagement for patients on intensified insulin therapy? a randomised, controlled trial
    • Biermann E, Dietrich W, Rihl J, Standl E. Are there time and cost savings by using telemanagement for patients on intensified insulin therapy? A randomised, controlled trial. Computer Methods and Programs in Biomedicine 2002; 69:137-146.
    • (2002) Computer Methods and Programs in Biomedicine , vol.69 , pp. 137-146
    • Biermann, E.1    Dietrich, W.2    Rihl, J.3    Standl, E.4
  • 36
    • 84860390613 scopus 로고    scopus 로고
    • DIABNET: A qualitative model-based advisory system for therapy planning in gestational diabetes
    • Hernando ME, Gomez EJ, del Pozo F, Corcoy R. DIABNET: a qualitative model-based advisory system for therapy planning in gestational diabetes. Medical Informatics (London) 1996; 21:359-374.
    • (1996) Medical Informatics (London) , vol.21 , pp. 359-374
    • Hernando, M.E.1    Gomez, E.J.2    Del Pozo, F.3    Corcoy, R.4
  • 41
    • 0021080916 scopus 로고
    • Bicentric evaluation of a teaching and treatment programme for type 1 (insulin-dependent) diabetic patients: Improvement of metabolic control and other measures of diabetes care for up to 22 months
    • Muhlhauser I, Jorgens V, Berger M, Graninger W, Gurtler W, Hornke L, Kunz A, Schernthaner G, Scholz V, Voss HE. Bicentric evaluation of a teaching and treatment programme for type 1 (insulin-dependent) diabetic patients: improvement of metabolic control and other measures of diabetes care for up to 22 months. Diabetologia 1983; 25:470-476.
    • (1983) Diabetologia , vol.25 , pp. 470-476
    • Muhlhauser, I.1    Jorgens, V.2    Berger, M.3    Graninger, W.4    Gurtler, W.5    Hornke, L.6    Kunz, A.7    Schernthaner, G.8    Scholz, V.9    Voss, H.E.10
  • 47
    • 0242300680 scopus 로고    scopus 로고
    • Who is downloading the free AIDA v4.3a interactive educational diabetes computer software? A 1-year survey of 3864 downloads
    • Lehmann ED. Who is downloading the free AIDA v4.3a interactive educational diabetes computer software? A 1-year survey of 3864 downloads. Diabetes Technology & Therapeutics 2003; 5:879-890.
    • (2003) Diabetes Technology & Therapeutics , vol.5 , pp. 879-890
    • Lehmann, E.D.1
  • 48
    • 0024387209 scopus 로고
    • SESAM-DIABETE, an expert system for insulin-requiring diabetic patient education
    • Levy M, Ferrand P, Chirat V. SESAM-DIABETE, an expert system for insulin-requiring diabetic patient education. Computers and Biomedical Research 1989; 22:442-453.
    • (1989) Computers and Biomedical Research , vol.22 , pp. 442-453
    • Levy, M.1    Ferrand, P.2    Chirat, V.3
  • 49
    • 0022617950 scopus 로고
    • Personal computer programs to assist with self-monitoring of blood glucose and self-adjustment of insulin dosage
    • Pernick NL, Rodbard D. Personal computer programs to assist with self-monitoring of blood glucose and self-adjustment of insulin dosage. Diabetes Care 1986; 9:61-69.
    • (1986) Diabetes Care , vol.9 , pp. 61-69
    • Pernick, N.L.1    Rodbard, D.2
  • 50
    • 0026575329 scopus 로고
    • Assessment of experts approach to insulin therapy and development of a simulator for diabetes insulin adjustment
    • Hauser T, Kraegen EW, Campbell LV, Compton PJ, Sammut C, Chisholm DJ. Assessment of experts approach to insulin therapy and development of a simulator for diabetes insulin adjustment. Diabetes Care 1992; 15: 221-231.
    • (1992) Diabetes Care , vol.15 , pp. 221-231
    • Hauser, T.1    Kraegen, E.W.2    Campbell, L.V.3    Compton, P.J.4    Sammut, C.5    Chisholm, D.J.6
  • 51
    • 0021871568 scopus 로고
    • The evaluation of a pocket computer as an aid to insulin dose determination by patients
    • Chanoch LH, Jovanovic L, Peterson CM. The evaluation of a pocket computer as an aid to insulin dose determination by patients. Diabetes Care 1985; 8:172-176.
    • (1985) Diabetes Care , vol.8 , pp. 172-176
    • Chanoch, L.H.1    Jovanovic, L.2    Peterson, C.M.3
  • 55
    • 0028823945 scopus 로고
    • Measurement of glucose in diabetic subjects using noninvasive transdermal extraction
    • Tamada JA, Bohannon NJV, Potts RO. Measurement of glucose in diabetic subjects using noninvasive transdermal extraction. Nature Medicine 1995; 1:1198-1201.
    • (1995) Nature Medicine , vol.1 , pp. 1198-1201
    • Tamada, J.A.1    Bohannon, N.J.V.2    Potts, R.O.3
  • 58
    • 0032754795 scopus 로고    scopus 로고
    • Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: A pilot study
    • Bode BW, Gross TM, Thornton KR, Mastrototaro JJ. Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study. Diabetes Research and Clinical Practice 1999; 46: 183-190.
    • (1999) Diabetes Research and Clinical Practice , vol.46 , pp. 183-190
    • Bode, B.W.1    Gross, T.M.2    Thornton, K.R.3    Mastrototaro, J.J.4
  • 59
    • 0345862180 scopus 로고    scopus 로고
    • Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS)
    • Schaepelynck-Belicar P, Vague P, Simonin G, Lassmann-Vague V. Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS). Diabetes & Metabolism 2003; 29: 608-612.
    • (2003) Diabetes & Metabolism , vol.29 , pp. 608-612
    • Schaepelynck-Belicar, P.1    Vague, P.2    Simonin, G.3    Lassmann-Vague, V.4
  • 60
    • 0041666413 scopus 로고    scopus 로고
    • Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs
    • Guerci B, Floriot M, Bohme P, Durain D, Benichou M, Jellimann S, Drouin P. Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs. Diabetes Care 2003; 26:582-589.
    • (2003) Diabetes Care , vol.26 , pp. 582-589
    • Guerci, B.1    Floriot, M.2    Bohme, P.3    Durain, D.4    Benichou, M.5    Jellimann, S.6    Drouin, P.7
  • 61
    • 0141921502 scopus 로고    scopus 로고
    • Computerized generation of circadian sensor modal days with continuous glucose monitoring for comparison of various insulin regimens based on insulin glargine in type 1 diabetes
    • Howorka K, Pumprla J, Gabriel M, Thoma H, Schabmann A. Computerized generation of circadian sensor modal days with continuous glucose monitoring for comparison of various insulin regimens based on insulin glargine in type 1 diabetes. International Journal of Artificial Organs 2003; 26:728-734.
    • (2003) International Journal of Artificial Organs , vol.26 , pp. 728-734
    • Howorka, K.1    Pumprla, J.2    Gabriel, M.3    Thoma, H.4    Schabmann, A.5
  • 62
    • 0016259390 scopus 로고
    • The artificial beta cell-a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system)
    • Pfeiffer EF, Thum C, Clemens AH. The artificial beta cell-a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system). Hormone and Metabolic Research 1974; 6:339-342.
    • (1974) Hormone and Metabolic Research , vol.6 , pp. 339-342
    • Pfeiffer, E.F.1    Thum, C.2    Clemens, A.H.3
  • 63
    • 0017338283 scopus 로고
    • The development of Biostator, a glucose controlled insulin infusion system (GCIIS)
    • Clemens AH, Chang PH, Myers RW. The development of Biostator, a glucose controlled insulin infusion system (GCIIS). Hormone and Metabolic Research 1977; 7(Suppl.):23-33.
    • (1977) Hormone and Metabolic Research , vol.7 , Issue.SUPPL. , pp. 23-33
    • Clemens, A.H.1    Chang, P.H.2    Myers, R.W.3
  • 65
    • 0017103199 scopus 로고
    • An improved control algorithm for an artificial beta-cell
    • Botz CK. An improved control algorithm for an artificial beta-cell. IEEE Transactions on Biomedical Engineering 1974; 23:252-255.
    • (1974) IEEE Transactions on Biomedical Engineering , vol.23 , pp. 252-255
    • Botz, C.K.1
  • 71
    • 0020365559 scopus 로고
    • An optimal control model of diabetes mellitus
    • Swan GW. An optimal control model of diabetes mellitus. Bulletin of Mathematical Biology 1982; 44:793-808.
    • (1982) Bulletin of Mathematical Biology , vol.44 , pp. 793-808
    • Swan, G.W.1
  • 72
    • 0024883144 scopus 로고
    • Application of optimal control theory to diabetes mellitus
    • Ollerton RL. Application of optimal control theory to diabetes mellitus. International Journal of Control 1989; 50:2503-2522.
    • (1989) International Journal of Control , vol.50 , pp. 2503-2522
    • Ollerton, R.L.1
  • 73
    • 0024475895 scopus 로고
    • Optimal insulin infusion resulting from a mathematical model of blood glucose dynamics
    • Fisher ME, Teo KL. Optimal insulin infusion resulting from a mathematical model of blood glucose dynamics. IEEE Transactions on Biomedical Engineering 1989; 36:479-486.
    • (1989) IEEE Transactions on Biomedical Engineering , vol.36 , pp. 479-486
    • Fisher, M.E.1    Teo, K.L.2
  • 78
    • 0021747298 scopus 로고
    • Closed-loop glycemic control with a wearable artificial endocrine pancreas. Variations in daily insulin requirements to glycemic response
    • Shichiri M, Kawamori R, Hakui N, Yamasaki Y, Abe H. Closed-loop glycemic control with a wearable artificial endocrine pancreas. Variations in daily insulin requirements to glycemic response. Diabetes 1984; 33: 1200-1202.
    • (1984) Diabetes , vol.33 , pp. 1200-1202
    • Shichiri, M.1    Kawamori, R.2    Hakui, N.3    Yamasaki, Y.4    Abe, H.5
  • 79
    • 0022270358 scopus 로고
    • Control of diabetes with artificial systems for insulin delivery-algorithm independent limitations revealed by a modeling study
    • Cobelli C, Mari A. Control of diabetes with artificial systems for insulin delivery-algorithm independent limitations revealed by a modeling study. IEEE Transactions on Biomedical Engineering 1985; 32:840-845.
    • (1985) IEEE Transactions on Biomedical Engineering , vol.32 , pp. 840-845
    • Cobelli, C.1    Mari, A.2
  • 81
    • 0027972684 scopus 로고
    • [Lys(B28), Pro(B29)]-human insulin. A rapidly absorbed analogue of human insulin
    • Howey DC, Bowsher RR, Brunelle RL, Woodworth JR. [Lys(B28), Pro(B29)]-human insulin. A rapidly absorbed analogue of human insulin. Diabetes 1994; 43:396-402.
    • (1994) Diabetes , vol.43 , pp. 396-402
    • Howey, D.C.1    Bowsher, R.R.2    Brunelle, R.L.3    Woodworth, J.R.4
  • 82
    • 0031304935 scopus 로고    scopus 로고
    • Closed-loop subcutaneous insulin infusion algorithm with a short-acting insulin analog for long-term clinical application of a wearable artificial endocrine pancreas
    • Shimoda S, Nishida K, Sakakida M, Konno Y, Ichinose K, Uehara M, Nowak T, Shichiri M. Closed-loop subcutaneous insulin infusion algorithm with a short-acting insulin analog for long-term clinical application of a wearable artificial endocrine pancreas. Frontiers of Medical and Biological Engineering 1997; 8:197-211.
    • (1997) Frontiers of Medical and Biological Engineering , vol.8 , pp. 197-211
    • Shimoda, S.1    Nishida, K.2    Sakakida, M.3    Konno, Y.4    Ichinose, K.5    Uehara, M.6    Nowak, T.7    Shichiri, M.8
  • 83
    • 0031914389 scopus 로고    scopus 로고
    • Enhanced, simplified glucose sensors: Long-term clinical application of wearable artificial endocrine pancreas
    • Shichiri M, Sakakida M, Nishida K, Shimoda S. Enhanced, simplified glucose sensors: long-term clinical application of wearable artificial endocrine pancreas. Artificial Organs 1998; 22:32-42.
    • (1998) Artificial Organs , vol.22 , pp. 32-42
    • Shichiri, M.1    Sakakida, M.2    Nishida, K.3    Shimoda, S.4
  • 84
    • 0013305737 scopus 로고    scopus 로고
    • Development of closed-loop intraperitoneal insulin infusion algorithm for a implantable artificial endocrine pancreas
    • Shimoda S, Nishida K, Sakakida M, Matsuo Y, Araki E. Development of closed-loop intraperitoneal insulin infusion algorithm for a implantable artificial endocrine pancreas. Diabetes 2001; 50(Suppl. 2):A3.
    • (2001) Diabetes , vol.50 , Issue.2 SUPPL.
    • Shimoda, S.1    Nishida, K.2    Sakakida, M.3    Matsuo, Y.4    Araki, E.5
  • 86
    • 0013011237 scopus 로고    scopus 로고
    • From external to implantable insulin pump, can we close the loop?
    • Renard E, Costalat G, Bringer J. From external to implantable insulin pump, can we close the loop? Diabetes & Metabolism 2002; 28:S19-S25.
    • (2002) Diabetes & Metabolism , vol.28
    • Renard, E.1    Costalat, G.2    Bringer, J.3
  • 89
    • 0036055927 scopus 로고    scopus 로고
    • Model predictive control of blood glucose in type I diabetics using subcutaneous glucose measurements
    • Lynch SM, Bequette BW. Model predictive control of blood glucose in type I diabetics using subcutaneous glucose measurements. Proceedings of the 2002 American Control Conference, 2002; 4039-4043.
    • (2002) Proceedings of the 2002 American Control Conference , pp. 4039-4043
    • Lynch, S.M.1    Bequette, B.W.2
  • 90
    • 0032171725 scopus 로고    scopus 로고
    • Neural predictive controller for insulin delivery using the subcutaneous route
    • Trajanoski Z, Wach P. Neural predictive controller for insulin delivery using the subcutaneous route. IEEE Transactions on Biomedical Engineering 1998; 45:1122-1134.
    • (1998) IEEE Transactions on Biomedical Engineering , vol.45 , pp. 1122-1134
    • Trajanoski, Z.1    Wach, P.2
  • 93
    • 0032432616 scopus 로고    scopus 로고
    • Overestimation of minimal model glucose effectiveness in presence of insulin response is due to undermodeling
    • Cobelli C, Bettini F, Caumo A, Quon MJ. Overestimation of minimal model glucose effectiveness in presence of insulin response is due to undermodeling. American Journal of Physiology 1998; 275:E1031-E1036.
    • (1998) American Journal of Physiology , vol.275
    • Cobelli, C.1    Bettini, F.2    Caumo, A.3    Quon, M.J.4
  • 96
    • 0037332507 scopus 로고    scopus 로고
    • Closed-loop glucose control in critically ill patients using continuous glucose monitoring system (CGMS) in real time
    • Chee F, Fernando T, van Heerden PV. Closed-loop glucose control in critically ill patients using continuous glucose monitoring system (CGMS) in real time. IEEE Transactions on Information Technology in Biomedicine 2003; 7:43-53.
    • (2003) IEEE Transactions on Information Technology in Biomedicine , vol.7 , pp. 43-53
    • Chee, F.1    Fernando, T.2    Van Heerden, P.V.3
  • 98
  • 99
    • 0028332617 scopus 로고
    • An adaptive plasma glucose controller based on a nonlinear insulin/glucose model
    • Candas B, Radziuk J. An adaptive plasma glucose controller based on a nonlinear insulin/glucose model. IEEE Transactions on Biomedical Engineering 1994; 41:116-124.
    • (1994) IEEE Transactions on Biomedical Engineering , vol.41 , pp. 116-124
    • Candas, B.1    Radziuk, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.