From external to implantable insulin pump, can we close the loop?;De la pompe externe à la pompe implantable, la fermeture de la boucle est-elle possible?

Author keywords

Artificial beta cell; Closed loop; Glucose sensor; Insulin; Insulin pump

Indexed keywords

BIOMATERIAL; INSULIN;

EID: 0013011237     PISSN: 12623636     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (22)

References (32)
  • 1
    • 0031932903 scopus 로고    scopus 로고
    • Advances toward the implantable artificial pancreas for treatment of diabetes
    • Jaremko J, Rorstad O. Advances toward the implantable artificial pancreas for treatment of diabetes. Diabetes Care, 1998, 21, 444-450.
    • (1998) Diabetes Care , vol.21 , pp. 444-450
    • Jaremko, J.1    Rorstad, O.2
  • 2
    • 0019941176 scopus 로고
    • Clinical use of the insulin infusion pump in 100 patients with type 1 diabetes
    • Mecklenburg RS, Benson JW Jr, Becker NM, et al. Clinical use of the insulin infusion pump in 100 patients with type 1 diabetes. N Engl J Med, 1982, 307, 513-518.
    • (1982) N Engl J Med , vol.307 , pp. 513-518
    • Mecklenburg, R.S.1    Benson J.W., Jr.2    Becker, N.M.3
  • 3
    • 0021017996 scopus 로고
    • Long-term management of insulin-treated diabetic patients with continuous subcutaneous insulin infusion
    • Daubresse JC, Henrivaux P, Bailly A, Lemy C, Duchateau A. Long-term management of insulin-treated diabetic patients with continuous subcutaneous insulin infusion. Diabete Metab, 1983, 9, 45-52.
    • (1983) Diabete Metab , vol.9 , pp. 45-52
    • Daubresse, J.C.1    Henrivaux, P.2    Bailly, A.3    Lemy, C.4    Duchateau, A.5
  • 4
    • 0023220542 scopus 로고
    • Cross-over comparison of continuous insulin infusion and conventional injection treatment of type 1 diabetes
    • Helve E, Koivisto VA, Lehtonen A, Pelkonen R, Huttunen JK, Nikkila EA. Cross-over comparison of continuous insulin infusion and conventional injection treatment of type 1 diabetes. Acta Med Scand, 1987, 221, 385-393.
    • (1987) Acta Med Scand , vol.221 , pp. 385-393
    • Helve, E.1    Koivisto, V.A.2    Lehtonen, A.3    Pelkonen, R.4    Huttunen, J.K.5    Nikkila, E.A.6
  • 5
    • 0025013690 scopus 로고
    • Continuous subcutaneous insulin infusion (CSII), multiple injections (MI) and conventional insulin therapy (CT) in self-selecting insulin-dependent diabetic patients. A comparison of metabolic control, acute complications and patient preferences
    • Haakens K, Hanssen KF, Dahl-Jorgensen K, Vaaler S, Aagenaes O, Mosand R. Continuous subcutaneous insulin infusion (CSII), multiple injections (MI) and conventional insulin therapy (CT) in self-selecting insulin-dependent diabetic patients. A comparison of metabolic control, acute complications and patient preferences. J Int Med, 1990, 228, 457-464.
    • (1990) J Int Med , vol.228 , pp. 457-464
    • Haakens, K.1    Hanssen, K.F.2    Dahl-Jorgensen, K.3    Vaaler, S.4    Aagenaes, O.5    Mosand, R.6
  • 6
    • 0025182886 scopus 로고
    • Devices for insulin administration
    • Selam JL, Charles MA. Devices for insulin administration. Diabetes Care, 1990, 13, 955-979.
    • (1990) Diabetes Care , vol.13 , pp. 955-979
    • Selam, J.L.1    Charles, M.A.2
  • 7
    • 0024388702 scopus 로고
    • Subcutaneous insulin delivery: Present status
    • Houtzagers CMGJ. Subcutaneous insulin delivery: present status. Diabetic Med, 1989, 6, 754-761.
    • (1989) Diabetic Med , vol.6 , pp. 754-761
    • Houtzagers, C.M.G.J.1
  • 8
    • 0021686445 scopus 로고
    • Acute complications associated with insulin infusion pump therapy. Report of experience with 181 patients
    • Mecklenburg RS, Benson EA, Benson JW Jr, et al. Acute complications associated with insulin infusion pump therapy. Report of experience with 181 patients. JAMA, 1984, 252, 3265-3269.
    • (1984) JAMA , vol.252 , pp. 3265-3269
    • Mecklenburg, R.S.1    Benson, E.A.2    Benson J.W., Jr.3
  • 9
    • 0028929207 scopus 로고
    • Implementation of treatment protocols in the Diabetes Control and Complications Trial
    • The Diabetes Control and Complications Trial Research Group. Implementation of treatment protocols in the Diabetes Control and Complications Trial. Diabetes Care, 1995, 18, 361-376.
    • (1995) Diabetes Care , vol.18 , pp. 361-376
  • 10
    • 0031048313 scopus 로고    scopus 로고
    • Insulin lispro in CSII: Results of double-blind crossover study
    • Zinman B, Tildesley H, Chiasson JL, Tsui E, Strack T. Insulin lispro in CSII: results of double-blind crossover study. Diabetes, 1997, 46, 440-443.
    • (1997) Diabetes , vol.46 , pp. 440-443
    • Zinman, B.1    Tildesley, H.2    Chiasson, J.L.3    Tsui, E.4    Strack, T.5
  • 11
    • 0032086121 scopus 로고    scopus 로고
    • 1c and blood glucose stability in IDDM patients treated with lispro insulin analog in external pumps
    • 1c and blood glucose stability in IDDM patients treated with lispro insulin analog in external pumps. Diabetes Care, 1998, 21, 977-982.
    • (1998) Diabetes Care , vol.21 , pp. 977-982
    • Melki, V.1    Renard, E.2    Lassmann-Vague, V.3
  • 12
    • 0019465249 scopus 로고
    • The kinetics of peritoneal insulin absorption
    • Schade DS, Eaton RP, Davis T, et al. The kinetics of peritoneal insulin absorption. Metabolism, 1981, 30, 149-155.
    • (1981) Metabolism , vol.30 , pp. 149-155
    • Schade, D.S.1    Eaton, R.P.2    Davis, T.3
  • 13
    • 0019950749 scopus 로고
    • Intraperitoneal insulin administration produces a positive portal-systemic blood insulin gradient in unanesthetized, unrestrained swine
    • Nelson JA, Stephen R, Landau ST, Wilson DE, Tyler FH. Intraperitoneal insulin administration produces a positive portal-systemic blood insulin gradient in unanesthetized, unrestrained swine. Metabolism, 1982, 31, 969-972.
    • (1982) Metabolism , vol.31 , pp. 969-972
    • Nelson, J.A.1    Stephen, R.2    Landau, S.T.3    Wilson, D.E.4    Tyler, F.H.5
  • 14
    • 0028918227 scopus 로고
    • Feasibility of intraperitoneal insulin therapy with programmable implantable pumps in IDDM: A multicenter study
    • Hanaire-Broutin H, Broussolle C, Jeandidier N, et al. Feasibility of intraperitoneal insulin therapy with programmable implantable pumps in IDDM: A multicenter study. Diabetes Care, 1995, 18, 388-392.
    • (1995) Diabetes Care , vol.18 , pp. 388-392
    • Hanaire-Broutin, H.1    Broussolle, C.2    Jeandidier, N.3
  • 15
    • 0027955099 scopus 로고
    • French multicenter experience of implantable insulin pumps
    • Broussolle C, Jeandidier N, Hanaire-Broutin H, the EVADIAC Study Group. French multicenter experience of implantable insulin pumps. Lancet, 1994, 343, 514-515.
    • (1994) Lancet , vol.343 , pp. 514-515
    • Broussolle, C.1    Jeandidier, N.2    Hanaire-Broutin, H.3
  • 16
    • 0036241609 scopus 로고    scopus 로고
    • 1c between implantable insulin pumps using U400 HOE 21 Ph insulin and external pumps using lispro in type 1 diabetic patients: A pilot study
    • 1c between implantable insulin pumps using U400 HOE 21 Ph insulin and external pumps using lispro in type 1 diabetic patients: a pilot study. Diabetes Metab, 2002, 28, 133-137.
    • (2002) Diabetes Metab , vol.28 , pp. 133-137
    • Catargi, B.1    Meyer, L.2    Melki, V.3    Renard, E.4    Jeandidier, N.5
  • 17
    • 0032813998 scopus 로고    scopus 로고
    • Improved stability of insulin delivery from implanted pumps using a new preparation process for infused insulin
    • Renard E, Souche C, Jacques-Apostol D, et al. Improved stability of insulin delivery from implanted pumps using a new preparation process for infused insulin. Diabetes Care, 1999, 22, 1371-1372.
    • (1999) Diabetes Care , vol.22 , pp. 1371-1372
    • Renard, E.1    Souche, C.2    Jacques-Apostol, D.3
  • 18
    • 0035135478 scopus 로고    scopus 로고
    • Clinical evaluation of a newly designed compliant side port catheter for an insulin implantable pump
    • Gin H, Melki V, Guerci B, Catargi B, EVADIAC Study Group. Clinical evaluation of a newly designed compliant side port catheter for an insulin implantable pump. Diabetes Care, 2001, 24, 175.
    • (2001) Diabetes Care , vol.24 , pp. 175
    • Gin, H.1    Melki, V.2    Guerci, B.3    Catargi, B.4
  • 19
    • 0029799449 scopus 로고    scopus 로고
    • Insulin underdelivery from implanted pumps using peritoneal route: Determinant role of insulin-pump compatibility
    • Renard E, Bouteleau S, Jacques-Apostol D, et al. Insulin underdelivery from implanted pumps using peritoneal route: determinant role of insulin-pump compatibility. Diabetes Care, 1996, 19, 812-817.
    • (1996) Diabetes Care , vol.19 , pp. 812-817
    • Renard, E.1    Bouteleau, S.2    Jacques-Apostol, D.3
  • 20
    • 0030838866 scopus 로고    scopus 로고
    • Use of implantable insulin pumps: The EVADIAC position
    • Lassmann-Vague V, Guerci B, Hanaire-Broutin H, et al on behalf of the EVADIAC Group. Use of implantable insulin pumps: The EVADIAC position. Diabetes Metab, 1997, 23, 234-240.
    • (1997) Diabetes Metab , vol.23 , pp. 234-240
    • Lassmann-Vague, V.1    Guerci, B.2    Hanaire-Broutin, H.3
  • 21
    • 0027133563 scopus 로고
    • Experience with intraperitoneal insulin infusion from implantable programmable systems in type 1 (insulin-dependent) diabetes mellitus previously treated by external pumps
    • Renard E, Lauton D, Bonifacj C, et al. Experience with intraperitoneal insulin infusion from implantable programmable systems in type 1 (insulin-dependent) diabetes mellitus previously treated by external pumps. Diabetes Metab, 1993, 19, 364-371.
    • (1993) Diabetes Metab , vol.19 , pp. 364-371
    • Renard, E.1    Lauton, D.2    Bonifacj, C.3
  • 22
    • 0028807108 scopus 로고
    • Development of the implantable glucose sensor: What are the prospects and why is it taking so long?
    • Gough D, Armour JC. Development of the implantable glucose sensor: what are the prospects and why is it taking so long? Diabetes, 1995, 44, 1005-1009.
    • (1995) Diabetes , vol.44 , pp. 1005-1009
    • Gough, D.1    Armour, J.C.2
  • 23
    • 0030852196 scopus 로고    scopus 로고
    • Advances and prospects in glucose assay technology
    • Gough DA, Armour JC, Baker DA. Advances and prospects in glucose assay technology. Diabetologia, 1997, 40 (Suppl 2), S102-S107.
    • (1997) Diabetologia , vol.40 , Issue.SUPPL. 2
    • Gough, D.A.1    Armour, J.C.2    Baker, D.A.3
  • 24
    • 0027102347 scopus 로고
    • In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue
    • Johnson KW, Mastrototaro JJ, Howey DC et al. In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue. Biosens Bioelectron, 1992, 7, 709-714.
    • (1992) Biosens Bioelectron , vol.7 , pp. 709-714
    • Johnson, K.W.1    Mastrototaro, J.J.2    Howey, D.C.3
  • 25
    • 0027746317 scopus 로고
    • The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human subcutaneous tissue and plasma
    • Kerner W, Kiwit M, Linke B, Keck FS, Zier H, Pfeiffer EF. The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human subcutaneous tissue and plasma. Biosens Bioelectron, 1993, 8, 473-482.
    • (1993) Biosens Bioelectron , vol.8 , pp. 473-482
    • Kerner, W.1    Kiwit, M.2    Linke, B.3    Keck, F.S.4    Zier, H.5    Pfeiffer, E.F.6
  • 26
    • 0023324607 scopus 로고
    • Time-dependent inactivation of immobilized glucose oxidase and catalase
    • Tse PHS, Gough DA. Time-dependent inactivation of immobilized glucose oxidase and catalase. Biotech Bioengin, 1986, 29, 705-713.
    • (1986) Biotech Bioengin , vol.29 , pp. 705-713
    • Tse, P.H.S.1    Gough, D.A.2
  • 27
    • 0025689061 scopus 로고
    • Application of chronic intravascular blood glucose sensor in dogs
    • Armour JC, Lucisano JY, McKean BD, Gough DA. Application of chronic intravascular blood glucose sensor in dogs. Diabetes, 1990, 39, 1519-1526.
    • (1990) Diabetes , vol.39 , pp. 1519-1526
    • Armour, J.C.1    Lucisano, J.Y.2    McKean, B.D.3    Gough, D.A.4
  • 28
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • Endocrinol Metab 40
    • Rebrin K, Steil GM, Van Antwerp WP, Mastrototaro JJ. Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol, 1999, 277 (Endocrinol Metab 40), E561-E571.
    • (1999) Am J Physiol , vol.277
    • Rebrin, K.1    Steil, G.M.2    Van Antwerp, W.P.3    Mastrototaro, J.J.4
  • 29
    • 0010615480 scopus 로고    scopus 로고
    • Glucose sensor control of an implantable insulin pump
    • 509-P
    • Shah R, Miller M, Zhang Y et al. Glucose sensor control of an implantable insulin pump (Abstract). Diabetes, 2000, 49 (Suppl 1), A125-A126, 509-P.
    • (2000) Diabetes , vol.49 , Issue.SUPPL. 1
    • Shah, R.1    Miller, M.2    Zhang, Y.3
  • 30
    • 0001770139 scopus 로고    scopus 로고
    • First combined implantations of a long-term IV glucose sensor and an intra-peritoneal insulin pump in diabetic patients
    • Renard E, Costalat G, Moran B et al. First combined implantations of a long-term IV glucose sensor and an intra-peritoneal insulin pump in diabetic patients (Abstract). Diabetes, 2001, 50 (Suppl 2), A3, 12-OR.
    • (2001) Diabetes , vol.50 , Issue.SUPPL. 2
    • Renard, E.1    Costalat, G.2    Moran, B.3
  • 31
    • 0010545344 scopus 로고    scopus 로고
    • First implantations of a long term glucose sensor connected to insulin pumps in diabetic humans
    • Renard E, Jovanovic L, Costalat G et al. First implantations of a long term glucose sensor connected to insulin pumps in diabetic humans (Abstract). Diabetologia, 2001, 44 (Suppl 1), A45, 169.
    • (2001) Diabetologia , vol.44 , Issue.SUPPL. 1
    • Renard, E.1    Jovanovic, L.2    Costalat, G.3
  • 32
    • 4243540564 scopus 로고    scopus 로고
    • Pompe à insuline implantée avec détecteur de glucose IV à long terme exactitude de la mesure glycémique et premiers essais de perfusion d'insuline "en boucle fermée"
    • Renard E, Shah R, Miller M et al. Pompe à insuline implantée avec détecteur de glucose IV à long terme exactitude de la mesure glycémique et premiers essais de perfusion d'insuline "en boucle fermée" (Abstract). Diabetes Metab, 2002, 28, 1S31, O62.
    • (2002) Diabetes Metab , vol.28 , Issue.1 S31
    • Renard, E.1    Shah, R.2    Miller, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.