메뉴 건너뛰기




Volumn 108, Issue 1-2 SPEC. ISS., 2005, Pages 778-783

Data analysis of surface plasmon resonance biosensor based on phase detection

Author keywords

Micro array; Phase detection; Resolution; SPR biosensor

Indexed keywords

ARRAYS; COHERENT LIGHT; DATA REDUCTION; ELECTROMAGNETIC WAVES; PHASE MODULATION; PROTEINS; SURFACE PLASMON RESONANCE;

EID: 19744378160     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2004.12.094     Document Type: Conference Paper
Times cited : (11)

References (9)
  • 1
    • 0344177897 scopus 로고    scopus 로고
    • Present and future of surface plasmon resonance biosensors
    • J. Homola Present and future of surface plasmon resonance biosensors Anal. Bioanal. Chem. 337 2003 528 539
    • (2003) Anal. Bioanal. Chem. , vol.337 , pp. 528-539
    • Homola, J.1
  • 2
    • 0036199586 scopus 로고    scopus 로고
    • A perspective on protein microarrays
    • P. Mitchell A perspective on protein microarrays Nat. Biotechnol. 20 2002 225 229
    • (2002) Nat. Biotechnol. , vol.20 , pp. 225-229
    • Mitchell, P.1
  • 3
    • 0032626631 scopus 로고    scopus 로고
    • Surface plasmon resonance sensors: Review
    • J. Homola Surface plasmon resonance sensors: review Sens. Actuators B 54 1999 3 15
    • (1999) Sens. Actuators B , vol.54 , pp. 3-15
    • Homola, J.1
  • 4
    • 2142673727 scopus 로고    scopus 로고
    • Simulation and analysis of surface plasmon resonance biosensor based on phase detection
    • Y. Xinglong, W. Dingxin, and Y. Zibo Simulation and analysis of surface plasmon resonance biosensor based on phase detection Sens. Actuators B 91 2003 285 290
    • (2003) Sens. Actuators B , vol.91 , pp. 285-290
    • Xinglong, Y.1    Dingxin, W.2    Zibo, Y.3
  • 5
    • 0038587436 scopus 로고    scopus 로고
    • High-sensitivity sensor based on surface plasmon resonance and heterodyne interferometry
    • C.-M. Wu, Z.-C. Jian, S.-F. Joe, and L.-B. Chang High-sensitivity sensor based on surface plasmon resonance and heterodyne interferometry Sens. Actuators B 92 2003 133 136
    • (2003) Sens. Actuators B , vol.92 , pp. 133-136
    • Wu, C.-M.1    Jian, Z.-C.2    Joe, S.-F.3    Chang, L.-B.4
  • 6
    • 0032672151 scopus 로고    scopus 로고
    • Surface plasmon resonance sensors based on diffraction gratings and prism couplers: Sensitivity comparison
    • J. Homola, I. Roudela, and S. Yee Surface plasmon resonance sensors based on diffraction gratings and prism couplers: sensitivity comparison Sens. Actuators B 54 1999 16 24
    • (1999) Sens. Actuators B , vol.54 , pp. 16-24
    • Homola, J.1    Roudela, I.2    Yee, S.3
  • 7
    • 0001303943 scopus 로고    scopus 로고
    • Imaging surface plasmon resonance sensor based on multiple wavelength: Sensitivity consideration
    • K. Johaseu, H. Arwin, I. Lundstrom, and B. Liedberg Imaging surface plasmon resonance sensor based on multiple wavelength: sensitivity consideration Rev. Sci. Instrum. 71 9 2000 3531 3538
    • (2000) Rev. Sci. Instrum. , vol.71 , Issue.9 , pp. 3531-3538
    • Johaseu, K.1    Arwin, H.2    Lundstrom, I.3    Liedberg, B.4
  • 9
    • 0029885724 scopus 로고    scopus 로고
    • Resolution and sensitivity in surface plasmon microscopy and sensing
    • E.M. Yeatman Resolution and sensitivity in surface plasmon microscopy and sensing Biosens. Bioelectron. 11 1996 635 649
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 635-649
    • Yeatman, E.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.