메뉴 건너뛰기




Volumn 13, Issue 3, 2005, Pages 152-156

What have we learned about laryngeal physiology from high-speed digital videoendoscopy?

Author keywords

High speed imaging; Mucosal wave; Vibration; Vocal folds; Voice; Voice disorders

Indexed keywords

ALGORITHM; AUDITORY CORTEX; CAMERA; ENDOSCOPY; HIGH SPEED VIDEOENDOSCOPY; HUMAN; INFORMATION PROCESSING; LARYNGOGRAPHY; LARYNX; LARYNX DISORDER; LINGUISTICS; PHONATION; PITCH; PRIORITY JOURNAL; REVIEW; SINGING; VOCAL CORD;

EID: 19744370241     PISSN: 10689508     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.moo.0000163451.98079.ba     Document Type: Review
Times cited : (65)

References (27)
  • 1
    • 0000281103 scopus 로고
    • High-speed motion pictures of the human vocal cords
    • Farnsworth D. High-Speed Motion Pictures of the Human Vocal Cords. Bell Telephone Records 1940; 18:203-208.
    • (1940) Bell Telephone Records , vol.18 , pp. 203-208
    • Farnsworth, D.1
  • 4
    • 0033638770 scopus 로고    scopus 로고
    • Vocal fold vibrations: High-speed video imaging, kymography and acoustic analysis
    • Larsson H, Hertegård S, Lindestad P-A, Hammarberg B. Vocal fold vibrations: high-speed video imaging, kymography and acoustic analysis. Laryngoscope 2000; 110:2117-2122.
    • (2000) Laryngoscope , vol.110 , pp. 2117-2122
    • Larsson, H.1    Hertegård, S.2    Lindestad, P.-A.3    Hammarberg, B.4
  • 5
    • 0033800481 scopus 로고    scopus 로고
    • Functional imaging of vocal fold vibration: Digital multi-slice-high- speed-kymography
    • Wittenberg Th, Tigges M, Mergell P, Eysholdt U. Functional Imaging of Vocal Fold Vibration: Digital Multi-Slice-High-Speed-Kymography. J Voice 2000; 14:422-442.
    • (2000) J Voice , vol.14 , pp. 422-442
    • Wittenberg, Th.1    Tigges, M.2    Mergell, P.3    Eysholdt, U.4
  • 6
    • 0029991874 scopus 로고    scopus 로고
    • Videokymography-high speed-line scanning of vocal fold vibrations
    • Švec J, Schutte HK. Videokymography-High speed-line scanning of vocal fold vibrations. J Voice 1996; 10:201-205.
    • (1996) J Voice , vol.10 , pp. 201-205
    • Švec, J.1    Schutte, H.K.2
  • 7
    • 0344073953 scopus 로고    scopus 로고
    • First results of clinical application of videokymography
    • Schutte HK, Švec J, Šram F. First results of clinical application of videokymography. Laryngoscope 1998; 108:1206-1210.
    • (1998) Laryngoscope , vol.108 , pp. 1206-1210
    • Schutte, H.K.1    Švec, J.2    Šram, F.3
  • 8
    • 0038654420 scopus 로고    scopus 로고
    • An automatic method to quantify the vibration properties of human vocal folds via videokymography
    • Qui Q, Schutte HK, Gu L, Yu Q. An automatic method to quantify the vibration properties of human vocal folds via videokymography. Folia Phoniatr Logop 2003; 55:128-136.
    • (2003) Folia Phoniatr Logop , vol.55 , pp. 128-136
    • Qui, Q.1    Schutte, H.K.2    Gu, L.3    Yu, Q.4
  • 9
    • 0021795023 scopus 로고
    • Stroboscopy - A pertinent laryngeal examination
    • Kitzing P. Stroboscopy - a pertinent laryngeal examination. J Otolaryngol 1985; 14:151-157.
    • (1985) J Otolaryngol , vol.14 , pp. 151-157
    • Kitzing, P.1
  • 10
    • 0036599127 scopus 로고    scopus 로고
    • Laryngeal gestures during stop production using high-speed digital images
    • Hong KH, Kim HK, Niimi S. Laryngeal gestures during stop production using high-speed digital images. J Voice 2002; 16:207-214.
    • (2002) J Voice , vol.16 , pp. 207-214
    • Hong, K.H.1    Kim, H.K.2    Niimi, S.3
  • 11
    • 0032848109 scopus 로고    scopus 로고
    • Qualitative and quantitative analysis of voice onset by means of a multidimensional voice analysis system (MVAS) using high-speed imaging
    • Köster O, Marx B, Gemmar P, et al. Qualitative and quantitative analysis of voice onset by means of a multidimensional voice analysis system (MVAS) using high-speed imaging. J Voice 1999; 13:355-374.
    • (1999) J Voice , vol.13 , pp. 355-374
    • Köster, O.1    Marx, B.2    Gemmar, P.3
  • 12
    • 0041779346 scopus 로고    scopus 로고
    • Simultaneous analysis of vocal fold vibration and transglottal airflow; Exploring a new experimental set-up
    • Granqvist S, Hertegård S, Larsson H, Sundberg J. Simultaneous analysis of vocal fold vibration and transglottal airflow; Exploring a new experimental set-up. J Voice 2003; 17:319-330.
    • (2003) J Voice , vol.17 , pp. 319-330
    • Granqvist, S.1    Hertegård, S.2    Larsson, H.3    Sundberg, J.4
  • 14
    • 0042338771 scopus 로고    scopus 로고
    • Glissando: Laryngeal motorics and acoustics
    • Hoppe U, Rosanowski F, Dollinger M, et al. Glissando: laryngeal motorics and acoustics. J Voice 2003; 17:370-376.
    • (2003) J Voice , vol.17 , pp. 370-376
    • Hoppe, U.1    Rosanowski, F.2    Dollinger, M.3
  • 16
    • 0035077390 scopus 로고    scopus 로고
    • Voice source characteristics in mongolian 'throat singing' studied with high-speed imaging technique, acustic spectra, and inverse filtering
    • Lindestad P-Å, Södersten M, Merker B, Granqvist S. Voice source characteristics in mongolian 'throat singing' studied with high-speed imaging technique, acustic spectra, and inverse filtering. J Voice 2001; 15:78-85.
    • (2001) J Voice , vol.15 , pp. 78-85
    • Lindestad, P.-Å.1    Södersten, M.2    Merker, B.3    Granqvist, S.4
  • 17
    • 10844235507 scopus 로고    scopus 로고
    • Vocal fold vibration and voice source aperiodicity in 'dist' tones: A study of a timbral ornament in rock singing
    • Zangger Borch D, Sundberg J, Lindestad P-Å, Thalén M. Vocal fold vibration and voice source aperiodicity in 'dist' tones: a study of a timbral ornament in rock singing. Logoped Phoniatr Vocol 2004; 29:147-153. High-speed imaging was used to study the complex voice source behaviour in a particular rock singing style
    • (2004) Logoped Phoniatr Vocol , vol.29 , pp. 147-153
    • Zangger Borch, D.1    Sundberg, J.2    Lindestad, P.-Å.3    Thalén, M.4
  • 18
    • 6844222852 scopus 로고    scopus 로고
    • Quantitative measurement of mucosal wave by high-speed photography in excised larynges
    • Jiang JJ, Yumoto E, Lin SJ, et al. Quantitative measurement of mucosal wave by high-speed photography in excised larynges. Ann Otol Rhinol Laryngol 1998; 107:98-103.
    • (1998) Ann Otol Rhinol Laryngol , vol.107 , pp. 98-103
    • Jiang, J.J.1    Yumoto, E.2    Lin, S.J.3
  • 19
    • 0036276343 scopus 로고    scopus 로고
    • High-precision measurement of the vocal fold length and vibratory amplitudes
    • Schuberth S, Phys D, Hoppe U, et al. High-precision measurement of the vocal fold length and vibratory amplitudes. Laryngoscope 2002; 112:1043-1049.
    • (2002) Laryngoscope , vol.112 , pp. 1043-1049
    • Schuberth, S.1    Phys, D.2    Hoppe, U.3
  • 20
    • 10644237084 scopus 로고    scopus 로고
    • Calibration of high-speed imaging by laser triangulation
    • Larsson H, Hertegård S. Calibration of high-speed imaging by laser triangulation. Logoped Phoniatr Vocol 2004; 29:154-161. The authors present validation of a quantification method using laser triangulation and a single laser device for objective measurements of structures in the larynx and of mucosal movements both in horizontal and vertical planes.
    • (2004) Logoped Phoniatr Vocol , vol.29 , pp. 154-161
    • Larsson, H.1    Hertegård, S.2
  • 21
    • 0035453923 scopus 로고    scopus 로고
    • Measurement of human Vocal fold vibrations with laser triangulation
    • Manneberg G, Hertegård S, Liljencrants J. Measurement of human Vocal fold vibrations with laser triangulation. Opt Eng 2001; 40:2041-2044.
    • (2001) Opt Eng , vol.40 , pp. 2041-2044
    • Manneberg, G.1    Hertegård, S.2    Liljencrants, J.3
  • 23
    • 0141818379 scopus 로고    scopus 로고
    • Measurement and interpretation of irregular vocal cord fold vibrations
    • [Epub 2003 Apr 04]
    • Eysholdt U, Rosanowski F, Hoppe U. Measurement and interpretation of irregular vocal cord fold vibrations. HNO 2003; 51:710-716. ([Epub 2003 Apr 04])
    • (2003) HNO , vol.51 , pp. 710-716
    • Eysholdt, U.1    Rosanowski, F.2    Hoppe, U.3
  • 25
    • 10644229262 scopus 로고    scopus 로고
    • Ventricular fold vibraton in voice production: A high-speed imaging study with kymographic, acoustic and perceptual analyses of a voice patient and a vocally healthy subject
    • Lindestad P-Å, Blixt V, Pahlberg-Olsson J, Hammarberg B. Ventricular fold vibraton in voice production: a high-speed imaging study with kymographic, acoustic and perceptual analyses of a voice patient and a vocally healthy subject. Logoped Phoniatr Vocol 2004; 29:162-170. In this study, high-speed imaging was used to study the mechanism of ventricular fold phonation.
    • (2004) Logoped Phoniatr Vocol , vol.29 , pp. 162-170
    • Lindestad, P.-Å.1    Blixt, V.2    Pahlberg-Olsson, J.3    Hammarberg, B.4
  • 26
    • 1842678469 scopus 로고    scopus 로고
    • High-speed imaging of the voicing source in laryngectomees during production of voiced-voiceless distinctions for stop consonants
    • Lundstrom E, Hammarberg B. High-speed imaging of the voicing source in laryngectomees during production of voiced-voiceless distinctions for stop consonants. Logoped Phoniatr Vocol 2004; 29:31-40. In this study, high-speed imaging was used for analysing and explaining the mechanisms of phonation in individuals who had undergone a laryngectomy.
    • (2004) Logoped Phoniatr Vocol , vol.29 , pp. 31-40
    • Lundstrom, E.1    Hammarberg, B.2
  • 27
    • 0842330446 scopus 로고    scopus 로고
    • Value of digital high-speed endoscopy in addition to videofluoroscopic imaging of the neoglottis in tracheoesophageal speech
    • Van As CJ, Op De Coul BM, Eysholdt U, Hilgers FJ. Value of digital high-speed endoscopy in addition to videofluoroscopic imaging of the neoglottis in tracheoesophageal speech. Acta Otolaryngol 2004; 124: 82-89.
    • (2004) Acta Otolaryngol , vol.124 , pp. 82-89
    • Van As, C.J.1    Op De Coul, B.M.2    Eysholdt, U.3    Hilgers, F.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.