Volumn 29, Issue 4, 2004, Pages 154-161

Calibration of high-speed imaging by laser triangulation

Author keywords

Calibration; Endoscope; Glottal area; Larynx; Laser; Mucosal wave; Triangulation; Vocal fold; Vocal fold vibrations

Indexed keywords

ACCURACY; ADULT; ARTICLE; CALIBRATION; COMPUTER PROGRAM; ENDOSCOPY; FEMALE; HUMAN; LARYNX; LARYNX MUCOSA; LASER; MALE; MEASUREMENT; NORMAL HUMAN; PHONATION; PITCH; PRIORITY JOURNAL; VIBRATION; VOCAL CORD; VOICE;

EID: 10644237084     PISSN: 14015439     EISSN: None     Source Type: Journal    
DOI: 10.1080/14015430410024353     Document Type: Article
Times cited : (32)

References (15)
  • 1
    • 0033638770 scopus 로고    scopus 로고
    • Vocal fold vibrations: High-speed imaging, kymography, and acoustic analysis: A preliminary report
    • Larsson H, Hammarberg B, Hertegård S, Lindestad PÅ. Vocal fold vibrations: high-speed imaging, kymography, and acoustic analysis: a preliminary report. Laryngoscope 2000; 110: 2117-22.
    • (2000) Laryngoscope , vol.110 , pp. 2117-2122
    • Larsson, H.1    Hammarberg, B.2    Hertegård, S.3    Lindestad, P.Å.4
  • 2
    • 0036276343 scopus 로고    scopus 로고
    • High-precision measurement of the vocal fold length and vibratory amplitudes
    • Schuberth S, Hoppe U, Dollinger M, Lohscheller J, Eysholdt U. High-precision measurement of the vocal fold length and vibratory amplitudes. Laryngoscope 2002; 112: 1043-9.
    • (2002) Laryngoscope , vol.112 , pp. 1043-1049
    • Schuberth, S.1    Hoppe, U.2    Dollinger, M.3    Lohscheller, J.4    Eysholdt, U.5
  • 3
    • 0036937973 scopus 로고    scopus 로고
    • Mögllchkeit endolaryngealer morphometrischer Messungen mit einem neuen Laserlichtverfahren
    • Aug
    • Schade G, Hess M, Rassow B. Mögllchkeit endolaryngealer morphometrischer Messungen mit einem neuen Laserlichtverfahren. HNO. 2002 Aug; 50(8): 753-5.
    • (2002) HNO , vol.50 , Issue.8 , pp. 753-755
    • Schade, G.1    Hess, M.2    Rassow, B.3
  • 4
    • 0003272029 scopus 로고    scopus 로고
    • Calibration of High-speed imaging by laser triangulation
    • Schutte H, editor. [Conference on CD-ROM]. Groningen: Groningen Voice Research laboratory
    • Larsson H, Hertegård S, Mannerberg G. Calibration of High-speed imaging by laser triangulation. In: Schutte H, editor. Fifth International Conference: Advances in Quantitative Laryngology. [Conference on CD-ROM]. Groningen: Groningen Voice Research laboratory, 2001.
    • (2001) Fifth International Conference: Advances in Quantitative Laryngology
    • Larsson, H.1    Hertegård, S.2    Mannerberg, G.3
  • 6
    • 84937190283 scopus 로고    scopus 로고
    • Using laser triangulation to measure vertical distance and displacement of laryngeal mucosa during phonation
    • Hertegård S, Björck G, Manneberg G. Using laser triangulation to measure vertical distance and displacement of laryngeal mucosa during phonation. Phonoscope 1998; 1: 179-85.
    • (1998) Phonoscope , vol.1 , pp. 179-185
    • Hertegård, S.1    Björck, G.2    Manneberg, G.3
  • 8
    • 0028062104 scopus 로고
    • Noninvasive measurement of traveling wave velocity in the canine larynx
    • Nasri S, Sercarz JA, Berke GS. Noninvasive measurement of traveling wave velocity in the canine larynx. Ann Otol Rhinol Laryngol 1994; 103: 758-66.
    • (1994) Ann. Otol. Rhinol. Laryngol. , vol.103 , pp. 758-766
    • Nasri, S.1    Sercarz, J.A.2    Berke, G.S.3
  • 11
    • 0032849640 scopus 로고    scopus 로고
    • Simultaneous videofluorographic and dual-channel electroglottographic registration of the vertical laryngeal position in various phonatory tasks
    • Laukkanen AM, Takalo R, Vilkman E, Nummenranta J, Lipponen T. Simultaneous videofluorographic and dual-channel electroglottographic registration of the vertical laryngeal position in various phonatory tasks. J Voice 1999; 13: 60-71.
    • (1999) J. Voice , vol.13 , pp. 60-71
    • Laukkanen, A.M.1    Takalo, R.2    Vilkman, E.3    Nummenranta, J.4    Lipponen, T.5
  • 12
    • 10644245511 scopus 로고
    • Stereo-Laryngoscopy: A new method to extract vertical movement of the vocal fold during vibration
    • Titze I, Scherer R, editors. Denver: The Denver Center for the Performing Arts 1991
    • Kakita Y, Hirano M, Kawasaki H, Matsuo K. Stereo-Laryngoscopy: a new method to extract vertical movement of the vocal fold during vibration. In: Titze I, Scherer R, editors. Vocal Fold Physiology Biomechanics, Acoustics, and Phonatory Control. Denver: The Denver Center for the Performing Arts; 1991; 1991. p. 191-201.
    • (1991) Vocal Fold Physiology Biomechanics, Acoustics, and Phonatory Control , pp. 191-201
    • Kakita, Y.1    Hirano, M.2    Kawasaki, H.3    Matsuo, K.4
  • 14
    • 0028845909 scopus 로고
    • Comparisons among aerodynamic, electroglottographic, and acoustic spectral measures of female voice
    • Holmberg EB, Hillman RE, Perkell JS, Guiod PC, Goldman SL. Comparisons among aerodynamic, electroglottographic, and acoustic spectral measures of female voice. J Speech Hear Res 1995; 38: 1212-23,
    • (1995) J. Speech Hear Res. , vol.38 , pp. 1212-1223
    • Holmberg, E.B.1    Hillman, R.E.2    Perkell, J.S.3    Guiod, P.C.4    Goldman, S.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.