메뉴 건너뛰기




Volumn 25, Issue 21, 2004, Pages 5199-5208

Bone bonding to hydroxyapatite and titanium surfaces on femoral stems retrieved from human subjects at autopsy

Author keywords

Degradation; Electron microscopy; Hydroxyapatite; Plasma spraying

Indexed keywords

BONDING; COATINGS; HYDROXYAPATITE; IMPLANTS (SURGICAL); PROSTHETICS; TITANIUM;

EID: 1942486777     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.biomaterials.2003.12.018     Document Type: Article
Times cited : (75)

References (22)
  • 1
    • 0024581092 scopus 로고
    • The effect of hydroxyapatite coating on bone growth into porous titanium alloy implants
    • Oonishi H., Yamamoto M., Ishimaru H., Tsuji E., Kushitani S., Aono M., Ukon Y. The effect of hydroxyapatite coating on bone growth into porous titanium alloy implants. J Bone Surg Br. 71(2):1989;213-216.
    • (1989) J Bone Surg Br , vol.71 , Issue.2 , pp. 213-216
    • Oonishi, H.1    Yamamoto, M.2    Ishimaru, H.3    Tsuji, E.4    Kushitani, S.5    Aono, M.6    Ukon, Y.7
  • 2
    • 0026491395 scopus 로고
    • Long-term retrospective studies on hydroxyapatite-coated endosteal and subperiosteal implants
    • Golec T.S., Krauser J.T. Long-term retrospective studies on hydroxyapatite-coated endosteal and subperiosteal implants. Dent Clin North Am. 36:1992;39-65.
    • (1992) Dent Clin North Am , vol.36 , pp. 39-65
    • Golec, T.S.1    Krauser, J.T.2
  • 4
    • 0035001735 scopus 로고    scopus 로고
    • Mechanical and histological evaluations of hydroxyapatite-coated and noncoated Ti6Al4 V implants in tibia bone
    • Chang C.K., Wu J.S., Mao D.L., Ding C.X. Mechanical and histological evaluations of hydroxyapatite-coated and noncoated Ti6Al4. V implants in tibia bone J Biomed Mater Res. 56(1):2001;17-23.
    • (2001) J Biomed Mater Res , vol.56 , Issue.1 , pp. 17-23
    • Chang, C.K.1    Wu, J.S.2    Mao, D.L.3    Ding, C.X.4
  • 5
    • 0027533829 scopus 로고
    • The effect of dissolution on plasma sprayed hydroxyapatite coatings on titanium
    • Whitehead R.Y., Lucas L.C., Lacefield W.R. The effect of dissolution on plasma sprayed hydroxyapatite coatings on titanium. Clin Mater. 12:1993;31-39.
    • (1993) Clin Mater , vol.12 , pp. 31-39
    • Whitehead, R.Y.1    Lucas, L.C.2    Lacefield, W.R.3
  • 7
    • 0035869769 scopus 로고    scopus 로고
    • Physicochemical study of plasma-sprayed hydroxyapatite-coated implants in humans
    • Macdonald D.E., Betts F., Stranick M., Doty S., Boskey A.L. Physicochemical study of plasma-sprayed hydroxyapatite-coated implants in humans. J Biomed Mater Res. 54:2001;480-490.
    • (2001) J Biomed Mater Res , vol.54 , pp. 480-490
    • MacDonald, D.E.1    Betts, F.2    Stranick, M.3    Doty, S.4    Boskey, A.L.5
  • 8
    • 0028501325 scopus 로고
    • Histomorphometry of hydroxyapatite coated and uncoated porous titanium bone implants
    • Moroni A., Caja V.L., Egger E.L., Trinchese L., Chao E.Y. Histomorphometry of hydroxyapatite coated and uncoated porous titanium bone implants. Biomaterials. 15(11):1994;926-930.
    • (1994) Biomaterials , vol.15 , Issue.11 , pp. 926-930
    • Moroni, A.1    Caja, V.L.2    Egger, E.L.3    Trinchese, L.4    Chao, E.Y.5
  • 9
    • 0028197668 scopus 로고
    • Hydroxyapatite coatings
    • Thomas K.A. Hydroxyapatite coatings. Orthopedics. 17(3):1994;267-278.
    • (1994) Orthopedics , vol.17 , Issue.3 , pp. 267-278
    • Thomas, K.A.1
  • 10
    • 0034038825 scopus 로고    scopus 로고
    • Morphometric and mechanical evaluation of titanium implant integration: Comparison of five surface structures
    • Svehla M., Morberg P., Zicate B., Bruce W., Sonnabend D., Walsh W.R. Morphometric and mechanical evaluation of titanium implant integration. comparison of five surface structures J Biomed Mater Res. 51(1):2000;15-22.
    • (2000) J Biomed Mater Res , vol.51 , Issue.1 , pp. 15-22
    • Svehla, M.1    Morberg, P.2    Zicate, B.3    Bruce, W.4    Sonnabend, D.5    Walsh, W.R.6
  • 13
    • 0027530301 scopus 로고
    • Osteolysis from a press-fit hydroxyapatite-coated implant
    • Bloebaum R.D., Dupont J.A. Osteolysis from a press-fit hydroxyapatite-coated implant. A case study. J Arthroplasty. 8(2):1993;195-202.
    • (1993) A Case Study. J Arthroplasty , vol.8 , Issue.2 , pp. 195-202
    • Bloebaum, R.D.1    Dupont, J.A.2
  • 15
    • 0026352034 scopus 로고
    • Hydroxyapatite-coated femoral stems: Histological analysis of components retrieved at autopsy
    • Bauer T.W., Geesink R.C.T., Zimmerman R., McMahon J.T. Hydroxyapatite-coated femoral stems. histological analysis of components retrieved at autopsy J Bone Jt Surg. 73-A:1991;1439-1452.
    • (1991) J Bone Jt Surg , vol.73 , pp. 1439-1452
    • Bauer, T.W.1    Geesink, R.C.T.2    Zimmerman, R.3    McMahon, J.T.4
  • 16
    • 0027643022 scopus 로고
    • Mechanisms and structure of the bone between bone and hydroxyapatite ceramics
    • Bagambisa F.B., Joos U., Schilli W. Mechanisms and structure of the bone between bone and hydroxyapatite ceramics. J Biomed Mater Res. 27:1993;1047-1055.
    • (1993) J Biomed Mater Res , vol.27 , pp. 1047-1055
    • Bagambisa, F.B.1    Joos, U.2    Schilli, W.3
  • 17
    • 0030144537 scopus 로고    scopus 로고
    • Eight year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants
    • Wheeler S.L. Eight year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants. Int J Oral Maxillofac Implants. 11:1996;340-350.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 340-350
    • Wheeler, S.L.1
  • 18
    • 0030152193 scopus 로고    scopus 로고
    • Differential effects of different forms of hydroxyapatite and hydroxyapatite/tricalcium phosphate particles on human monocyte/macrophages in vitro
    • Harada Y., Wang J.T., Doppalapudi V.A., Willis A.A., Jasty M., Harris W.H., Nagase M., Goldring S.R. Differential effects of different forms of hydroxyapatite and hydroxyapatite/tricalcium phosphate particles on human monocyte/macrophages in vitro. J Biomed Mater Res. 31(1):1996;19-26.
    • (1996) J Biomed Mater Res , vol.31 , Issue.1 , pp. 19-26
    • Harada, Y.1    Wang, J.T.2    Doppalapudi, V.A.3    Willis, A.A.4    Jasty, M.5    Harris, W.H.6    Nagase, M.7    Goldring, S.R.8
  • 19
    • 0027503584 scopus 로고
    • Uncemented acetabular components: Histologic analysis of retrieved hydroxyapatite-coated and porous implants
    • Bauer T.W., Stulberg B.N., Ming J., Geesink R.G.T. Uncemented acetabular components. histologic analysis of retrieved hydroxyapatite-coated and porous implants J Arthroplasty. 8:1993;167-177.
    • (1993) J Arthroplasty , vol.8 , pp. 167-177
    • Bauer, T.W.1    Stulberg, B.N.2    Ming, J.3    Geesink, R.G.T.4
  • 21
    • 0036132131 scopus 로고    scopus 로고
    • The ultrastructure of the plasma-sprayed hydroxyapatite-bone interface predisposing to bone bonding
    • Porter A.E., Hobbs L.W., Benezra Rosen V., Spector M. The ultrastructure of the plasma-sprayed hydroxyapatite-bone interface predisposing to bone bonding. Biomaterials. 23:2002;725-733.
    • (2002) Biomaterials , vol.23 , pp. 725-733
    • Porter, A.E.1    Hobbs, L.W.2    Benezra Rosen, V.3    Spector, M.4
  • 22
    • 1942502538 scopus 로고    scopus 로고
    • Effect of silicate substitution in sintered hydroxyapatite on remodelling processes at the bone-implant interface
    • in press.
    • Porter AE, Patel N, Skepper JN, Best SM, Bonfield W. Effect of silicate substitution in sintered hydroxyapatite on remodelling processes at the bone-implant interface. Biomaterials, in press.
    • Biomaterials
    • Porter, A.E.1    Patel, N.2    Skepper, J.N.3    Best, S.M.4    Bonfield, W.5