메뉴 건너뛰기




Volumn 19, Issue 21, 1998, Pages 1945-1955

Manufacture of porous biodegradable polymer conduits by an extrusion process for guided tissue regeneration

Author keywords

Biodegradable polymer; ; Conduit; Extrusion; Guided tissue regeneration; Poly(DL lactic co glycolic acid); Poly(L lactic acid); Polymer processing; Scaffold; Tissue engineering

Indexed keywords

BIODEGRADATION; BIOMEDICAL ENGINEERING; ELASTIC MODULI; EXTRUSION; HIGH TEMPERATURE EFFECTS; MECHANICAL PROPERTIES; PARTICLE SIZE ANALYSIS; POROSITY; SALTS; TISSUE; TRANSPLANTATION (SURGICAL);

EID: 18844477518     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(98)00099-4     Document Type: Article
Times cited : (345)

References (52)
  • 2
    • 0026087153 scopus 로고
    • A comparison of suture and tubulization nerve repair techniques in a primate
    • [2] Hentz VR, Rosen JM, Xiao S, McGill KC, Abrahem G. A comparison of suture and tubulization nerve repair techniques in a primate. J Hand Surg 1991;16A:251-61.
    • (1991) J Hand Surg , vol.16 A , pp. 251-261
    • Hentz, V.R.1    Rosen, J.M.2    Xiao, S.3    McGill, K.C.4    Abrahem, G.5
  • 3
    • 0023404852 scopus 로고
    • Prosthetic nerve grafts: A resorbable tube as an alternative to autogenous nerve grafting
    • [3] Bora FW, Bednar JM, Osterman AL, Brown MJ, Sumner AJ. Prosthetic nerve grafts: a resorbable tube as an alternative to autogenous nerve grafting. J Hand Surg 1987;12A:685-92.
    • (1987) J Hand Surg , vol.12 A , pp. 685-692
    • Bora, F.W.1    Bednar, J.M.2    Osterman, A.L.3    Brown, M.J.4    Sumner, A.J.5
  • 4
    • 0026332022 scopus 로고
    • Nerve regeneration through a two-ply biodegradable nerve guide in the rat and the influence of ACTH4-9 nerve growth factor
    • [4] Robinson PH, van der Lei B, Hoppen HJ, Leenslag JW, Pennings AJ, Niewenhuis P. Nerve regeneration through a two-ply biodegradable nerve guide in the rat and the influence of ACTH4-9 nerve growth factor. Microsurgery 1991;12:412-9.
    • (1991) Microsurgery , vol.12 , pp. 412-419
    • Robinson, P.H.1    Van Der Lei, B.2    Hoppen, H.J.3    Leenslag, J.W.4    Pennings, A.J.5    Niewenhuis, P.6
  • 5
    • 0031032517 scopus 로고    scopus 로고
    • Axonal regeneration through acellular muscle grafts
    • [5] Hall S. Axonal regeneration through acellular muscle grafts. J Anatomy 1997;190:57-71.
    • (1997) J Anatomy , vol.190 , pp. 57-71
    • Hall, S.1
  • 7
    • 2642675869 scopus 로고
    • Degenerated muscle grafts used for peripheral nerve repair in primates
    • [7] Glasby MA, Gschmeissner SE, Huang CL, de Souza BA. Degenerated muscle grafts used for peripheral nerve repair in primates. J Hand Surg 1986;11-B:347-51.
    • (1986) J Hand Surg , vol.11 B , pp. 347-351
    • Glasby, M.A.1    Gschmeissner, S.E.2    Huang, C.L.3    De Souza, B.A.4
  • 9
    • 0018920612 scopus 로고
    • Nerve regeneration through performed pseudosynovial tubes
    • [9] Lundborg G, Hanson H. Nerve regeneration through performed pseudosynovial tubes. J Hand Surg 1980;5:35-8.
    • (1980) J Hand Surg , vol.5 , pp. 35-38
    • Lundborg, G.1    Hanson, H.2
  • 10
    • 0018641612 scopus 로고
    • Regeneration of peripheral nerve through a performed tissue space
    • [10] Lundborg G, Hanson H. Regeneration of peripheral nerve through a performed tissue space. Brain Res 1979;178:573-6.
    • (1979) Brain Res , vol.178 , pp. 573-576
    • Lundborg, G.1    Hanson, H.2
  • 11
    • 0010368523 scopus 로고
    • The repair of peripheral nerves using porous tubular prostheses
    • Hausener HH, Taubenblat PW, editors. New Jersey: American Powder Metalurgy Institute Princeton
    • [11] Kuhn WE, Hall JL. The repair of peripheral nerves using porous tubular prostheses. In: Hausener HH, Taubenblat PW, editors. Modern developments in powder metalurgy. New Jersey: American Powder Metalurgy Institute Princeton, 1976:279-301.
    • (1976) Modern Developments in Powder Metalurgy , pp. 279-301
    • Kuhn, W.E.1    Hall, J.L.2
  • 12
    • 0025116502 scopus 로고
    • The morphology of regenerating peripheral nerves is modulated by the surface microgeometry of polymeric guidance channels
    • [12] Aebischer P, Guénard V, Valentini RF. The morphology of regenerating peripheral nerves is modulated by the surface microgeometry of polymeric guidance channels. Brain Res 1990; 531:211-8.
    • (1990) Brain Res , vol.531 , pp. 211-218
    • Aebischer, P.1    Guénard, V.2    Valentini, R.F.3
  • 13
    • 0027327739 scopus 로고
    • Implants of cultured schwann cells support axonal growth in the central nervous system of adult rats
    • [13] Montgomery CT, Robson JA. Implants of cultured schwann cells support axonal growth in the central nervous system of adult rats. Exp Neurol 1993;122:107-24.
    • (1993) Exp Neurol , vol.122 , pp. 107-124
    • Montgomery, C.T.1    Robson, J.A.2
  • 14
    • 0025299194 scopus 로고
    • New methods of transplanting purified glial cells into the brain
    • [14] Montgomery CT, Robson JA. New methods of transplanting purified glial cells into the brain. J Neurosci Meth 1990; 32:135-41.
    • (1990) J Neurosci Meth , vol.32 , pp. 135-141
    • Montgomery, C.T.1    Robson, J.A.2
  • 15
    • 0028230165 scopus 로고
    • Regrowth of axons within schwann cell-filled polycarbonate tubes implanted into the damaged optic tract and cerebral cortex of rats
    • [15] Harvey AR, Chen M, Plant GW, Dyson SE. Regrowth of axons within schwann cell-filled polycarbonate tubes implanted into the damaged optic tract and cerebral cortex of rats. Restor Neurol Neurosci 1994;6:221-37.
    • (1994) Restor Neurol Neurosci , vol.6 , pp. 221-237
    • Harvey, A.R.1    Chen, M.2    Plant, G.W.3    Dyson, S.E.4
  • 16
    • 0025093930 scopus 로고
    • Fibronectin-laminin combination enhances peripheral nerve regeneration across long gaps
    • [16] Woolley AL, Hollowell JP, Rich KM. Fibronectin-laminin combination enhances peripheral nerve regeneration across long gaps. Head Neck Surg 1990;103:509-18.
    • (1990) Head Neck Surg , vol.103 , pp. 509-518
    • Woolley, A.L.1    Hollowell, J.P.2    Rich, K.M.3
  • 17
    • 0020515378 scopus 로고
    • Spatial-temporal progress of peripheral nerve regeneration within a silicone chamber: Parameters for a bioassay
    • [17] Williams LR, Longe FM, Powell HC, Lundborg G, Varon S. Spatial-temporal progress of peripheral nerve regeneration within a silicone chamber: parameters for a bioassay. J Compar Neurol 1983;218:460-70.
    • (1983) J Compar Neurol , vol.218 , pp. 460-470
    • Williams, L.R.1    Longe, F.M.2    Powell, H.C.3    Lundborg, G.4    Varon, S.5
  • 18
    • 0023911027 scopus 로고
    • Entubulation repair with protein additives increases the maximum nerve gap distance successfully bridged with tubular prostheses
    • [18] Madison RD, Silva CF, Dikkes P. Entubulation repair with protein additives increases the maximum nerve gap distance successfully bridged with tubular prostheses. Brain Res 1988; 447:325-34.
    • (1988) Brain Res , vol.447 , pp. 325-334
    • Madison, R.D.1    Silva, C.F.2    Dikkes, P.3
  • 20
    • 0014299761 scopus 로고
    • Experimental improvements in the use of silastic cuff for peripheral nerve repair
    • [20] Ducker TB, Hayes GJ. Experimental improvements in the use of silastic cuff for peripheral nerve repair. J Neurosurg 1968; 28:582-7.
    • (1968) J Neurosurg , vol.28 , pp. 582-587
    • Ducker, T.B.1    Hayes, G.J.2
  • 22
    • 0023265095 scopus 로고
    • Nerve regeneration changes with filters of different pore size
    • [22] Jenq C, Jenq LL, Coggeshall RE. Nerve regeneration changes with filters of different pore size. Exp Neurol 1987;97:662-71.
    • (1987) Exp Neurol , vol.97 , pp. 662-671
    • Jenq, C.1    Jenq, L.L.2    Coggeshall, R.E.3
  • 23
    • 0022387090 scopus 로고
    • Nerve regeneration through holey silicone tubes
    • [23] Jenq C, Coggeshall E. Nerve regeneration through holey silicone tubes. Brain Res 1985;361:233-41.
    • (1985) Brain Res , vol.361 , pp. 233-241
    • Jenq, C.1    Coggeshall, E.2
  • 24
    • 0027328743 scopus 로고
    • Peripheral nerve regeneration across 14-mm gaps: A comparison of autograft and entubulation repair methods in the rat
    • [24] Keeley R, Atagi T, Sabelman E, Padilla J, Kadlcik S, Keeley A, Nguyen K, Rosen J. Peripheral nerve regeneration across 14-mm gaps: a comparison of autograft and entubulation repair methods in the rat. J Reconstr Microsurg 1993;9:349-60.
    • (1993) J Reconstr Microsurg , vol.9 , pp. 349-360
    • Keeley, R.1    Atagi, T.2    Sabelman, E.3    Padilla, J.4    Kadlcik, S.5    Keeley, A.6    Nguyen, K.7    Rosen, J.8
  • 26
    • 0021057941 scopus 로고
    • Nerve repair using a polyglactin tube and nerve graft: An experimental study in the rabbit
    • [26] Molander H, Engkvist O, Hägglund J, Olsson Y, Torebjörk E. Nerve repair using a polyglactin tube and nerve graft: an experimental study in the rabbit. Biomaterials 1983;4:276-80.
    • (1983) Biomaterials , vol.4 , pp. 276-280
    • Molander, H.1    Engkvist, O.2    Hägglund, J.3    Olsson, Y.4    Torebjörk, E.5
  • 27
    • 0025271268 scopus 로고
    • Clinical nerve reconstruction with a bioabsorbable polyglycolic acid tube
    • [27] Mackinnon SE, Dellon AL. Clinical nerve reconstruction with a bioabsorbable polyglycolic acid tube. Plast Reconstr Surg 1990;85:419-24.
    • (1990) Plast Reconstr Surg , vol.85 , pp. 419-424
    • Mackinnon, S.E.1    Dellon, A.L.2
  • 28
    • 0025762424 scopus 로고
    • The artificial nerve graft: A comparison of blended elastomerhydrogel with polyglycolic acid conduits
    • [28] Keeley RD, Nguyen KD, Stephanides MJ, Padilla J, Rosen JM. The artificial nerve graft: a comparison of blended elastomerhydrogel with polyglycolic acid conduits. J Reconstr Microsurg 1991;7:93-100.
    • (1991) J Reconstr Microsurg , vol.7 , pp. 93-100
    • Keeley, R.D.1    Nguyen, K.D.2    Stephanides, M.J.3    Padilla, J.4    Rosen, J.M.5
  • 29
    • 0023692281 scopus 로고
    • An alternative to the classical nerve graft for the management of the short nerve gap
    • [29] Dellon AL, Mackinnon SE. An alternative to the classical nerve graft for the management of the short nerve gap. Plast Reconstr Surg 1988;82:849-56.
    • (1988) Plast Reconstr Surg , vol.82 , pp. 849-856
    • Dellon, A.L.1    Mackinnon, S.E.2
  • 30
    • 0021189595 scopus 로고
    • Nerve regeneration through synthetic biodegradable nerve guides: Regulation by the target organ
    • [30] Seckel BR, Chiu TH, Nyilas E, Sidman RL. Nerve regeneration through synthetic biodegradable nerve guides: regulation by the target organ. Plast Reconstr Surg 1984;74:173-81.
    • (1984) Plast Reconstr Surg , vol.74 , pp. 173-181
    • Seckel, B.R.1    Chiu, T.H.2    Nyilas, E.3    Sidman, R.L.4
  • 31
    • 0021796098 scopus 로고
    • Increased rate of peripheral nerve regeneration using bioresorbable nerve guides and a laminin-containing gel
    • [31] Madison R, da Silva CF, Dikkes P, Chiu T, Sidman RL. Increased rate of peripheral nerve regeneration using bioresorbable nerve guides and a laminin-containing gel. Exp Neurol 1985;88:767-72.
    • (1985) Exp Neurol , vol.88 , pp. 767-772
    • Madison, R.1    Da Silva, C.F.2    Dikkes, P.3    Chiu, T.4    Sidman, R.L.5
  • 33
    • 0030152636 scopus 로고    scopus 로고
    • Light-microscopic and electron-microscopic evaluation of short-term nerve regeneration using a biodegradable poly(DL-lactide-ε-caprolacton) nerve guide
    • [33] den Dunnen WFA, Stokroos I, Blaauw EH, Holwerda A, Pennings AJ, Robinson PH, Schakenraad JM. Light-microscopic and electron-microscopic evaluation of short-term nerve regeneration using a biodegradable poly(DL-lactide-ε-caprolacton) nerve guide. J Biomed Mater Res 1996;31:105-15.
    • (1996) J Biomed Mater Res , vol.31 , pp. 105-115
    • Den Dunnen, W.F.A.1    Stokroos, I.2    Blaauw, E.H.3    Holwerda, A.4    Pennings, A.J.5    Robinson, P.H.6    Schakenraad, J.M.7
  • 35
    • 0025292580 scopus 로고
    • Two-ply biodegradable nerve guide: Basic aspects of design, construction and biological performance
    • [35] Hoppen HJ, Leenslag JW, Pennings AJ, van der Lei B, Robinson PH. Two-ply biodegradable nerve guide: basic aspects of design, construction and biological performance. Biomaterials 1990; 11:286-90.
    • (1990) Biomaterials , vol.11 , pp. 286-290
    • Hoppen, H.J.1    Leenslag, J.W.2    Pennings, A.J.3    Van Der Lei, B.4    Robinson, P.H.5
  • 37
    • 0024545983 scopus 로고
    • Tubulation for peripheral nerve gap: Its history and possibility
    • [37] Suematsu N. Tubulation for peripheral nerve gap: its history and possibility. Microsurgery 1989;10:71-4.
    • (1989) Microsurgery , vol.10 , pp. 71-74
    • Suematsu, N.1
  • 38
    • 0029900450 scopus 로고    scopus 로고
    • Fabrication of pliable biodegradable polymer foams to engineer soft tissues
    • [38] Wake MC, Gupta PK, Mikos AG. Fabrication of pliable biodegradable polymer foams to engineer soft tissues. Cell Transplant 1996;5:465-73.
    • (1996) Cell Transplant , vol.5 , pp. 465-473
    • Wake, M.C.1    Gupta, P.K.2    Mikos, A.G.3
  • 41
    • 0000660346 scopus 로고
    • Hollow-fiber membranes
    • Kirk RE, Othmer DF, editors. New York: Wiley
    • [41] Cabasso F. Hollow-fiber membranes. In: Kirk RE, Othmer DF, editors. Encyclopedia of Chemical Technology. New York: Wiley, 1980:492-517.
    • (1980) Encyclopedia of Chemical Technology , pp. 492-517
    • Cabasso, F.1
  • 42
    • 0028225229 scopus 로고
    • Different conduits in peripheral nerve surgery
    • [42] Brunelli GA, Vigasio A, Brunelli GR. Different conduits in peripheral nerve surgery. Microsurgery 1994;15:176-8.
    • (1994) Microsurgery , vol.15 , pp. 176-178
    • Brunelli, G.A.1    Vigasio, A.2    Brunelli, G.R.3
  • 45
    • 0032212853 scopus 로고    scopus 로고
    • Hydroxyapatite fiber reinforced poly(α-hydroxy ester) foams for bone regeneration
    • [45] Thomson RC, Yaszemski MJ, Powers JM, Mikos AG. Hydroxyapatite fiber reinforced poly(α-hydroxy ester) foams for bone regeneration. Biomaterials 1998;19:1935-43.
    • (1998) Biomaterials , vol.19 , pp. 1935-1943
    • Thomson, R.C.1    Yaszemski, M.J.2    Powers, J.M.3    Mikos, A.G.4
  • 46
    • 0021694228 scopus 로고
    • Advances in experimental techniques for mercury intrusion porosimetry
    • Matjevic E, Good RJ, editors New York: Plenum Press
    • [46] Winslow DN. Advances in experimental techniques for mercury intrusion porosimetry. In: Matjevic E, Good RJ, editors. Surface and colloid science. New York: Plenum Press, 1984:259-82.
    • (1984) Surface and Colloid Science , pp. 259-282
    • Winslow, D.N.1
  • 47
    • 0027575137 scopus 로고
    • Laminated three-dimensional biodegradable foams for use in tissue engineering
    • [47] Mikos AG, Sarakinos G, Leite SM, Vacanti JP, Langer R. Laminated three-dimensional biodegradable foams for use in tissue engineering. Biomaterials 1993;14:323-30.
    • (1993) Biomaterials , vol.14 , pp. 323-330
    • Mikos, A.G.1    Sarakinos, G.2    Leite, S.M.3    Vacanti, J.P.4    Langer, R.5
  • 48
    • 0018476499 scopus 로고
    • A comparative study of poly(glycolic acid) and catgut as suture materials histomorphology and mechanical properties
    • [48] Pavan A, Bosio M, Longo T. A comparative study of poly(glycolic acid) and catgut as suture materials histomorphology and mechanical properties. J Biomed Mater Res 1979;13:477-96.
    • (1979) J Biomed Mater Res , vol.13 , pp. 477-496
    • Pavan, A.1    Bosio, M.2    Longo, T.3
  • 49
    • 0020136873 scopus 로고
    • Biodegradation of surgical polymers
    • [49] Williams DF. Biodegradation of surgical polymers. J Mater Sci 1982;17:1233-46.
    • (1982) J Mater Sci , vol.17 , pp. 1233-1246
    • Williams, D.F.1
  • 50
    • 0021718521 scopus 로고
    • The in vivo and in vitro degradation of poly(glycolic acid) suture material as a function of applied strain
    • [50] Miller ND, Williams DF. The in vivo and in vitro degradation of poly(glycolic acid) suture material as a function of applied strain. Biomaterials 1984;5:365-8.
    • (1984) Biomaterials , vol.5 , pp. 365-368
    • Miller, N.D.1    Williams, D.F.2
  • 51
    • 0026059172 scopus 로고
    • Physico-mechanical properties of degradable polymers used in medical applications: A comparative study
    • [51] Engelberg I, Kohn J. Physico-mechanical properties of degradable polymers used in medical applications: a comparative study. Biomaterials 1991;12:292-304.
    • (1991) Biomaterials , vol.12 , pp. 292-304
    • Engelberg, I.1    Kohn, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.