메뉴 건너뛰기




Volumn 107, Issue 2, 2005, Pages 872-881

Development of a CCD-based fluorimeter for real-time PCR machine

Author keywords

CCD; Fluorescence detection system; Fluorescence image processing; LUM filter; Real time PCR

Indexed keywords

ALGORITHMS; CHARGE COUPLED DEVICES; DNA; ENZYMES; FLUORESCENCE; IMAGE PROCESSING; LIGHT EMITTING DIODES;

EID: 18544379312     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2004.12.042     Document Type: Article
Times cited : (11)

References (21)
  • 4
    • 0031022694 scopus 로고    scopus 로고
    • Continuous fluorescence monitoring of rapid cycle DNA amplification
    • C.T. Wittwer, M.G. Herrmann, A.A. Moss, and R.P. Rasmussen Continuous fluorescence monitoring of rapid cycle DNA amplification BioTechniques 22 1997 130 138
    • (1997) BioTechniques , vol.22 , pp. 130-138
    • Wittwer, C.T.1    Herrmann, M.G.2    Moss, A.A.3    Rasmussen, R.P.4
  • 5
    • 0030614426 scopus 로고    scopus 로고
    • The LightCycler™: A microvolume multisample fluorimeter with rapid temperature control
    • C.T. Wittwer, K.M. Ririe, R.V. Andrew, D.A. David, R.A. Gundry, and U.J. Balis The LightCycler™: a microvolume multisample fluorimeter with rapid temperature control BioTechniques 22 1997 176 181
    • (1997) BioTechniques , vol.22 , pp. 176-181
    • Wittwer, C.T.1    Ririe, K.M.2    Andrew, R.V.3    David, D.A.4    Gundry, R.A.5    Balis, U.J.6
  • 6
    • 12444320964 scopus 로고    scopus 로고
    • A fluorescence based assay for DNA damage by styrene oxide
    • R. Kumaran, and R. Kim A fluorescence based assay for DNA damage by styrene oxide Sens. Actuat. B 91 2003 205 210
    • (2003) Sens. Actuat. B , vol.91 , pp. 205-210
    • Kumaran, R.1    Kim, R.2
  • 7
    • 0037095347 scopus 로고    scopus 로고
    • A heater-integrated transparent microchannel chip for continuous flow PCR
    • S. Kai, Y. Akira, I. Yutaka, M. Shigeki, and M. Hiroaki A heater-integrated transparent microchannel chip for continuous flow PCR Sens. Actuat. B 84 2002 283 289
    • (2002) Sens. Actuat. B , vol.84 , pp. 283-289
    • Kai, S.1    Akira, Y.2    Yutaka, I.3    Shigeki, M.4    Hiroaki, M.5
  • 9
    • 18544378240 scopus 로고    scopus 로고
    • http://www.lightcycleronline.com/lc_sys_2/pdfs/flyer.pdf.
  • 11
    • 0032476319 scopus 로고    scopus 로고
    • Implementation of micromirror arrays as optical binary switches and amplitude modulators
    • E.S. Kolesar, P.B. Allen, J.W. Wilken, and J.T. Howard Implementation of micromirror arrays as optical binary switches and amplitude modulators Thin Solid Films 332 1998 1 9
    • (1998) Thin Solid Films , vol.332 , pp. 1-9
    • Kolesar, E.S.1    Allen, P.B.2    Wilken, J.W.3    Howard, J.T.4
  • 14
    • 18544386932 scopus 로고    scopus 로고
    • http://usa.hamamatsu.com/sys-glossary/highsensitivity.html
  • 15
    • 2342570922 scopus 로고    scopus 로고
    • A novel real time PCR machine with a miniature spectrometer for fluorescence sensing in a micro liter volume glass capillary
    • D.-S. Lee, M.-H. Wu, U. Ramesh, C.-W. Lin, T.-M. Lee, and H. Chen A novel real time PCR machine with a miniature spectrometer for fluorescence sensing in a micro liter volume glass capillary Sens. Actuat. B 100 2004 401 410
    • (2004) Sens. Actuat. B , vol.100 , pp. 401-410
    • Lee, D.-S.1    Wu, M.-H.2    Ramesh, U.3    Lin, C.-W.4    Lee, T.-M.5    Chen, H.6
  • 16
    • 0019635684 scopus 로고
    • Strategies for analyzing data from video fluorometric monitoring of liquid chromatographic effluents
    • C.J. Appelof, and E.R. Davidson Strategies for analyzing data from video fluorometric monitoring of liquid chromatographic effluents Anal. Chem. 53 1981 2053 2056
    • (1981) Anal. Chem. , vol.53 , pp. 2053-2056
    • Appelof, C.J.1    Davidson, E.R.2
  • 17
    • 33845558094 scopus 로고
    • Precision and accuracy of absorption-corrected molecular fluorescence measurements by the cell shift method
    • D.R. Christmann, S.R. Crouch, and A. Timnick Precision and accuracy of absorption-corrected molecular fluorescence measurements by the cell shift method Anal. Chem. 53 1983 2040 2044
    • (1983) Anal. Chem. , vol.53 , pp. 2040-2044
    • Christmann, D.R.1    Crouch, S.R.2    Timnick, A.3
  • 18
    • 0019527529 scopus 로고
    • Automated instrument for absorption-corrected molecular fluorescence measurements by the cell shift method
    • D.R. Christmann, S.R. Crouch, and A. Timnick Automated instrument for absorption-corrected molecular fluorescence measurements by the cell shift method Anal. Chem. 53 1981 276 280
    • (1981) Anal. Chem. , vol.53 , pp. 276-280
    • Christmann, D.R.1    Crouch, S.R.2    Timnick, A.3
  • 19
    • 18544377423 scopus 로고
    • Monte Carlo simulations on concentration self-quenching by statistical traps
    • J. Knoester, and J.E. Van Himbergen Monte Carlo simulations on concentration self-quenching by statistical traps J. Chem. Phys. 86 1987 3577 3582
    • (1987) J. Chem. Phys. , vol.86 , pp. 3577-3582
    • Knoester, J.1    Van Himbergen, J.E.2
  • 21
    • 12244268341 scopus 로고    scopus 로고
    • Detection of telomerase components by quantitative real-time on-line PCR analysis with the lightcycler
    • E. Thomas, K. Gerlinde, and P. Birgit Detection of telomerase components by quantitative real-time on-line PCR analysis with the lightcycler Biochemica 4 2000 16 19
    • (2000) Biochemica , vol.4 , pp. 16-19
    • Thomas, E.1    Gerlinde, K.2    Birgit, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.